SA-DACT Dialer <br /> The SA-DACT provides communications between the control The SA-DACT queues messages and transmits them based on <br /> panel and the central station over a telephone line system. It priority(alarm, supervisory,trouble,and monitor).Activations are <br /> transmits system status changes(events)to a compatible digital transmitted before restorations. <br /> alarm communicator receiver over the public switched telephone The SA-DACT is installed on the plastic assembly and connects to <br /> network.The dialer is capable of single, dual, or split reporting the main circuit board via a ribbon cable. <br /> of events to two different account and telephone numbers.The <br /> modem feature of the SA-DACT can also be used for uploading <br /> and downloading panel configuration, history,and current status SA-DACT specifications <br /> to a PC running the i0-C1J. Phone line type One or two loop-start lines on a public, <br /> SA-DACT Phone line 1 switched network <br /> wiring To wall <br /> Phone line 2 Phone line connector RJ-31/38X(C31/38)) <br /> phone jack <br /> Communication formats Contact ID(SIA DC-05) <br /> Phone cables Operating environment <br /> (supplied) RJ31 jacks Temperature 32 to 120°F(0 to 49°C) <br /> Humidity 0 to 93%RH,noncondensing at 90°F <br /> (32°C) <br /> ® ® The dialer phone lines connect <br /> no to connectors on the dialer's Compatible DACRs <br /> ®® npOL` main circuit board.Phone line 1 Receiver Models Formats <br /> L❑ ❑°'f° o connects to connector J4 and Ademco 685 Contact ID <br /> ¢_ a� phone line 2 connects to FBII CP220 Contact ID <br /> ❑❑-e connector J1. Osborne-Hoffman OH 2000 Contact ID <br /> oo❑❑❑❑o ° o Radionics D6600 Contact ID <br /> 0❑aQoo ❑ o Silent Knight 9800 Contact ID <br /> ❑e o$°o ° Sur-Gard SG-MLR1,MLR2 Contact ID <br /> Specifications <br /> Device loops 1 loop Class B,Class A optional,supporting Batteries Batteries must be sealed lead acid type only. <br /> up to 64 device addresses Maximum charging capacity=26 Ah. <br /> Notification appliance 2 Class B,Class A optional,2.5 amps each Loop circuit Maximum loop resistance:66 O.Maximum <br /> circuits loop capacitance:0.7 pF.Style 4,6,and 7 <br /> Power supply 3.75 A FWR total at 120/230 VAC 60 Hz wiring.64 isolators maximum <br /> 3.0 A FWR total at 230 VAC 50 Hz Loop circuit max 1.5 mA(see the UL and ULC compatibility <br /> 0.5 amps aux power detector standby current list for your panel for the maximum quantity <br /> NAC Operating voltage 24 VDC.NAC minimum voltage: 19.5 VDC of detectors per circuit) <br /> @ 20.4 V battery voltage Compatibility ID 100 <br /> SLC Loop operating 20 V peak-to-peak Alarm contact Form C 24 VDC @ 1 A(resistive load) <br /> voltage Trouble contact Form C 24 VDC @ 1 A(resistive load) <br /> Primary power 120 VAC,60 Hz,230 VAC 50-60 Hz Supervisory contact Form A 24 VDC @ 1 A(resistive load) <br /> Aux Power 1 24 VDC nominal at 500 mA.A SMK module Environmental Temperature:0 to 49°C(32 to 120°F). <br /> (Continuous circuit) is required when using the SIGA-UM module Humidity:0 to 93%RH,noncondensing <br /> to support two-wire smoke detectors. Terminal rating All terminals rated for 12 to 18 AWG(0.75 to <br /> Aux Power 2 24 VDC nominal at 500 mA. 2.5 sq mm) <br /> (Resettable circuit) Serial communications Voltage:2.55 V.Current:30 mA max <br /> Auxiliary output 19 to 25.7 VDC Remote annunciator 8 drops max,RS-485 Class B,Class A <br /> Base panel current draw Standby: 155 mA Alarm:204 mA Input zones 16 max. <br /> Battery placement 1064 cabinets accommodate up to 10 A/H Agency Listing UL,CSFM and ULC <br /> batteries.Use an external cabinet for larger <br /> battery sizes. <br /> Page 6 of 8 DATA S H E E 85005-0131 <br /> Not to be used for installation purposes. Issue 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.