My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1415 75TH ST SW HELION ENERGY 2023-12-11
>
Address Records
>
75TH ST SW
>
1415
>
HELION ENERGY
>
1415 75TH ST SW HELION ENERGY 2023-12-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2023 9:58:23 AM
Creation date
10/9/2023 10:43:49 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1415
Tenant Name
HELION ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OTTO ROSENAU & ASSOCIATES, INC. <br />Geotechnical Engineering, Construction Inspection & Materials Testing <br />PROPRIETARY ANCHOR ADHESIVE INSPECTION REPORT <br />Report Number: PAA453066 <br />Job Number: 23-0102 <br />Project Name: Helion Energy Control Room Permit: B2204-072 <br />Project Address: 1415 75th St SW, Everett <br />Client Name: Helion Energy, Inc. Inspector: Paul Kanikkeberg <br />Insp. Date: 02/23/2023 <br />Description / Location / Intended Use <br />#4 dowels epoxied into existing slab on grade at C.5-C.7/5.1-5.2 and C.6-C.8/5.9-6.1 for slab infill. Inspected to approved <br />plans and details. <br />Building Code & Year: 2018 IBC <br />❑� Reinforcing Steel ❑All Thread <br />Bar/Dowel Size & Quantity: #4 (30) Anchor Size & Quantity: <br />Rebar Manufacturer: Cascade Type of Steel (ASTM): ❑ A-36 ❑ F-1554 ❑ A-307 <br />Rebar Grade ❑ 40 ❑� 60 ❑ Other: Grade: ❑ 36 ❑ 50 ❑ 75 ❑ Other: <br />Type of Bar VA-615 ❑A-706 ❑Other: Does Contractor Need to Schedule Torque Verification? ❑ Yes ❑d No <br />[Special Ductile Quality (SDQ) Steel: No Reason (If No): <br />Iff— <br />Anchor Length: 18" Hole Depth: 4" Required Embedment: 4" <br />Hole Diameter: 5/8" <br />Concrete Thickness: 6" <br />Concrete Strength: Existing <br />Hole Orientation: ❑ Vertical Down ❑ Upwardly Inclined W Horizontal <br />Base Material: ke Normal Weight Concrete ❑ Lightweight Concrete ❑ CMU ❑ Brick ❑ Composite Deck <br />Hole Cleaning: ❑ Compressed Air ❑ Hand Pump W Vacuum Drill Bit ❑ Other <br />Compressed Air PSI: n/a Drill Bit (ANSI B212.15): Yes <br />Brushed: Yes Hole Condition: W Dry ❑ Damp ❑ Water Saturated ❑ Submerged <br />Adhesive Manufacturer/Type: Simpson SET 3G Expiration Date: 9/2/23 ICC ESR #: 4057 <br />Certified Installers: n/a <br />Weather: Indoors <br />Ambient Temperature: 60 <br />Substrate Temperature: 60 <br />Reference Standard(s) Used: Conforms?❑ Yes ❑ No <br />Comments: <br />�/ Date: 2023.02.28 <br />Copies to: � /�� , , <br />d❑ Client ❑d Engineer ❑ Others Technical Responsibility: 1 2:3 1 :08 -08 00 <br />V1 Owner ❑d Contractor <br />❑ Architect ❑d Building Dept Isaac Ruoff, Project Manager <br />This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this <br />report except in full, without written permission from our firm is strictly prohibited. <br />6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 -- Fax (206) 723-2221 <br />Form No.: ADMIN-86-03 (Rev 08119) Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.