Laserfiche WebLink
DAILY FIELD REPORT <br />AAR TESTING AND INSPECTION, INC. <br />7126 180th Ave NE, Suite C101 <br />Redmond, WA 98052 <br />425-881-5812 <br />Inspection Date <br />07/03/2023 <br />Report Number <br />DTG070323A <br />CLIENT INFORMATION <br />PROJECT INFORMATION <br />Contact <br />Project No. <br />23-413 <br />Company <br />Project Name <br />Helion Energy <br />Address <br />Address <br />1415 75th St SW <br />City <br />City <br />Everett <br />Contractor <br />Permit No. <br />B2307-015 <br />INSPECTION TYPE(S) STRUCTURE(S) / LOCATION(S) <br />Proprietary Anchors - Mechanical New building to the East, industrial storage rack base plate mechanical anchors <br />Weather Start Time End Time <br />09:00 AM <br />DRAWINGS / DOCUMENTS REFERENCED <br />INSPECTION OBSERVATION / REMARKS <br />Arrived on site, as requested, to inspect mechanical anchor torque for base plates of industrial storage racks. Verified KBTZ2 anchors, 1/2 inch <br />by 5 1/2 inch anchors were used. Verified 4 anchors per base plate were to a minimum depth of 3 1/2 inches, per manufacturer instructions <br />and ESR #4266. Verified torque in foot pounds to be minimum 50 ft lbs. <br />Items inspected are in conformance with approved plans, specifications, and jurisdictional requirements <br />Inspectors Name Report Date Reviewers Signature Reviewed By Reviewed Date <br />Inspectors Signature Del Green 07/05/2023 yy,V( Teajalam (TJ) Gounden 07/07/2023 <br />960A4B76-5DB2-48A4-8370-4136BB99DB1B <br />