Laserfiche WebLink
UMC <br />TM <br />Air Handling Unit <br />PROJECT: Helion - AHU 5 <br />LOCATION: Everett, WA <br />PROJECT #: 9038 <br />SYSTEM/UNIT: AHU-5 <br />Unit Data <br />Unit Manufacturer <br />Trane <br />Unit Model Number <br />YCD120C4LOAB <br />Unit Serial Number <br />L51103305D <br />Unit Discharge <br />Downblast <br />AHU-5/SF Filter Bank <br />Filter Manufacturer <br />Koch <br />Filter Type <br />Pleated <br />Actual MERV Rating <br />8 <br />Filter Qty - S1 <br />2 <br />Filter Size - S1 <br />16x20x2 <br />Filter Qty - S2 <br />2 <br />Filer Size - S2 <br />16x24x2 <br />Test Data <br />Design Supply Airflow <br />3210 CFM <br />Actual Supply Airflow <br />3222 CFM <br />Design Outside Airflow <br />835 CFM <br />Actual Outside Airflow <br />806 CFM <br />Design Return Airflow <br />3220 CFM <br />Actual Return Airflow <br />3650 CFM <br />Design Total Outlet Airflow <br />3200 CFM <br />Actual Total Outlet Airflow <br />3222 CFM <br />AHU-5/Supply Fan <br />Actual Fan RPM <br />949 RPM <br />Motor Operating HZ/Speed <br />1763 RPM <br />Motor Volts T1-T2 <br />482 Volts <br />Motor Volts T2-T3 <br />482 Volts <br />Motor Volts T1-T3 <br />483 Volts <br />Motor Amps T1 <br />3.40 Amps <br />Motor Amps T2 <br />3.70 Amps <br />Motor Amps T3 <br />3.80 Amps <br />DATE: 7/10/2023 <br />CONTACT: Brandon Bannister <br />AUTHOR: Sonny Dudoit <br />Tested By: Brandon Bannister <br />Date: 7/7/2023 <br />Motor Data <br />Motor Type Belt Drive <br />Nameplate Motor Manufacturer Marathon <br />Nameplate Motor Frame <br />145T-10 <br />Nameplate Motor HP <br />3 HP <br />Nameplate Motor Rated Volts <br />460 Volts <br />Nameplate Motor FL Amps <br />4.60 Amps <br />Nameplate Motor RPM <br />1725 RPM <br />Nameplate Motor Phase <br />3 <br />Nameplate Motor Hertz <br />60 Hz <br />Nameplate Motor Service Factor 1.15 <br />Brake Horsepower <br />2.93 BHP <br />Corrected FL Amps <br />4.38700760193504 Amps <br />Nominal Efficiency (0.00) <br />0.90 % <br />Motor Power Factor (0.00) <br />0.80 <br />Sheave Data <br />AHU-5/Supply Fan <br />Motor Sheave MFG <br />Browning <br />Motor Sheave Model <br />1 VP50X <br />Motor Sheave Diam. <br />4 3/4 in. <br />Motor Sheave Bore <br />7/8 in. <br />Fan Sheave MFG <br />Browning <br />Fan Sheave Diam. <br />6 1/4 in. <br />Fan Sheave Bore <br />1.00 in. <br />Number of Belts <br />1 <br />Belt Size <br />BX-51 <br />Sheave Center Line Distance <br />17.00 in. <br />Test Pressures <br />Actual Total SP <br />0.06 in. we <br />Suction SP <br />0.45 in. we <br />Discharge SP <br />0.51 in. we <br />O/A Damper Position <br />25 % <br />R/A Damper Position <br />75 % <br />UMC Page 5 of 8 <br />