My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1415 75TH ST SW HELION ENERGY 2023-12-11
>
Address Records
>
75TH ST SW
>
1415
>
HELION ENERGY
>
1415 75TH ST SW HELION ENERGY 2023-12-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2023 9:58:23 AM
Creation date
10/9/2023 10:43:49 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1415
Tenant Name
HELION ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROJECT INFORMATION <br />D <br />FIRE SPRINKLER PIPING PLAN <br />2 0 4 6 <br />SCALE Ire• =r-D• <br />Sprinkler1 1 Totale <br />STEEL SAMMY SIDEWINDER <br />ZEEPURUN <br />SAMMY SIDEWINDER <br />ALL THREAD ROD <br />SWIW?L RING- ryry%%ir <br />PIPE <br />STEEL SAMMY SIDEWINDER <br />ZEEPURUN <br />SAMMY SIDEWINDER <br />ALL THREAD ROD <br />SWIW?L RING- ryry%%ir <br />PIPE <br />CONTROL ROOM <br />ill" PLYWOOD SH <br />I4" METAL JOIST <br />8"ACOUSTICAL It <br />T <br />R <br />'P <br />aqi <br />q <br />HANGER SPACING - STEEL PIPE <br />FLEXIBLE DROP TO SPRINKLER <br />SIZE OF PIPE <br />MAXHANGER <br />WEIGHT OF WATER <br />NOTE: <br />SUPPORTED <br />SPACING <br />FILLED PIPE <br />BRANCHUNE 48"FLEXIBLE DROP LENGTH <br />1"(Sch 40) <br />12'-0 <br />2.051beIR <br />MAX NUMBER OF BENDS =6 <br />T MIN RADIUS =2"(UL) I7"(FM) <br />�1 � 22'.0 EQUIVALENT LENGTH <br />1 114"(Sch 40) <br />12'-0 <br />2.931be1R <br />1 1/2" (Sch 10) <br />15'-0 <br />3.041bs#t <br />FLEXIBLE DROP <br />2" (Sch 10) <br />15'-0 <br />4.221bs#t <br />MOUNTING BRACKET <br />2 112"(Sch 10) <br />15'-0 <br />5.891bsRt <br />CEILING <br />3" (Sch 10) <br />15'.0 <br />7.941beIR <br />- <br />SEMI RECESSED <br />4" (Sch 10) <br />15'-0 <br />11.781bsfl1 <br />SPRINKLER <br />6" (Sch 10) <br />15'-0 <br />23.031b.41 <br />BLDG SECTION <br />0 0 2 4 <br />1 <br />SCALE 1/4'= t'-0' <br />A <br />O <br />O Z' <br />2� <br />2 <br />`9 <br />� 00 <br />2 3 ,Z <br />Oc' <br />TIE-IN DETAIL <br />AREA OF WORK <br />- <br />t [BEE ®Ei�_.: - <br />D ASSEMBLV: <br />ETHING <br />RAMING @ 16" OC <br />WI-ATION <br />OWNER <br />EVERETT TECHNICAL PARK II LLC <br />12201 TUKWILLA INTERNATIONAL BLVD, <br />FLOOR <br />SEATTLE, WA 98168 <br />TENANT: <br />HELION ENERGY INCORPORATED <br />PROPERTY TAX NO: <br />28041100101000 <br />BUILDING INFORMATION <br />TYPE OF CONSTRUCTION. III-B <br />OCCUPANCY CLASSIFICATION: B/F-1 <br />SEISMIC DESIGN CATEGORY: D <br />CODE REFERENCES <br />NFPA 132019 EDITION <br />GENERAL PROJECT DESCRIPTION <br />MODIFY AND EXTEND THE EXISTING FIRE SPRINKLER SYSTEM <br />TO PROVIDE ADEQUATE FIRE PROTECTION FOR THE NEW <br />CONTROL ROOM ADDITION. <br />DESIGN CRITERIA <br />EXISTING ROOF LEVEL FIRE SPRINKLER SYSTEM <br />TO REMAIN AS IS- ESFR <br />NEW CONTROL ROOM FIRE SPRINKLER SYSTEM <br />LIGHT HAZARD .10 GPM / SQ. FT. <br />GENERAL NOTES <br />1. THREADED PIPE TO BE SCHEDULE 40 REGARDLESS OF SIZE. <br />2. ROLL GROOVED PIPE TO BE SCHEDULE 10 REGARDLESS OF <br />SIZE. <br />3. DRY SYSTEM PIPE TO BE BLACK, C FACTOR =100 PER NFPA <br />13 REQUIREMENTS. <br />4. ALL PIPING SHALL BE TESTED AT 200 PSI OR 50 PSI IN <br />EXCESS OF SYSTEM WORKING PRESSURE, WHICHEVER IS <br />GREATER. <br />5. EARTHQUAKE BRACING TO BE PROVIDED IN ACCORDANCE <br />WITH NFPA 13. <br />6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, <br />SHALL BE IN ACCORDANCE WITH NFPA 13. <br />7. ALL COMPONENTS SHALL BE ILL LISTED / FM APPROVED. <br />8. ALL ELECTRICAL WIRING SHALL BE PERFORMED BY OTHERS. <br />9. ALL FLFXHOSES TO BE VICTAULIC AH2 EITHER 48. OR 72' IN <br />LENGTH. <br />10. ALL HANGERS TO BE IN ACCORDANCE WITH NFPA 13. <br />11. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT <br />THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE <br />OWNER AND THEIR STRUCTURAL REPRESENTATIVE. <br />12. EXCEPT AS NOTED BELOW, ALL AREAS WHERE WET <br />PIPING IS PRESENT MUST BE HEATED OR INSULATED TO <br />MAINTAIN A MINIMUM OF 40°F. WHERE WET PIPING IS PRESENT <br />IN EXTERIOR WALLS FEEDING DRY SIDEWALL SPRINKLER <br />HEADS ON BALCONIES AND OTHER EXTERIOR SPACES, THE <br />FOLLOWING SHALL APPLY. (1) ALL PENETRATIONS THROUGH <br />THE EXTERIOR WALLS FOR THE DRY BARREL HEADS MUST BE <br />PROPERLY SEALED; (2) THE SPACE BETWEEN THE PIPING AND <br />THE EXTERIOR WALL INSIDE THE CAVITY MUST BE PROPERLY <br />INSULATED; (3) THE PIPE MUST NOT BE EMBEDDED IN THE <br />INSULATION; (4) NO INSULATION MUST BE PLACED BETWEEN <br />THE PIPING AND THE INTERIOR WALL; (5) THE TEMPERATURE <br />OF THE INTERIOR SPACE MUSE BE MAINTAINED AT MINIMUM <br />OF 60°F. <br />13. OWNER IS RESPONSIBLE FOR ALL MAINTENANCE AND <br />PROTECTION OF THE FIRE SPRINKLER SYSTEM(S). <br />14. PAINTING OF SPRINKLER PIPE AND PROTECTION OF PIPE <br />FROM PAINT OR CONSTRUCTION ACTIVITIES (SUCH AS FIRE <br />PROOFING) IS BY OTHERS AND EXCLUDED FROM THIS <br />CONTRACT. <br />15. THE FIRE SPRINKLER SYSTEMS SHALL BE MONITORED 24 <br />HOURS A DAY BY A CENTRAL STATION AND IS EXCLUDED <br />FROM THIS CONTRACT. <br />16, PER NFPA 132019 ED SECTION 16.2.7.5- A SUPPLY OF: (12) <br />SPARE SPRINKLERS, (1) SPRINKLER WRENCH AS SPECIFIED <br />BY THE MANUFACTURER FOR EACH TYPE OF SPRINKLER AND <br />A COMPLETE LIST OF ALL SPRINKLERS INSTALLED SHALL BE <br />LEFT IN THE SPRINKLER HEAD BOX AFTER PROJECT <br />COMPLETION. SPRINKLERS SHALL CORRESPOND TO THE <br />TYPES AND TEMPERATURES INSTALLED IN THE PROPERTY. <br />%116 Fire PrD States <br />lllll Fire Protection Co <br />t7*9 �r c aw.l ikepoua <br />14690 NE 957H ST, UNIT 101 <br />REDMOND, WA 98052 <br />TEL. 425.881.0100 <br />W W W.WSFP.COM <br />STATE LICENSE #WESTESF785LH <br />OWNERSHIP OF DOCUMENTS <br />..................7 <br />1 <br />ai11O <br />� � 1 <br />W <br />I Q y J <br />1 <br />I zO Z <br />U <br />1 <br />Z <br />1 U � <br />1 <br />1 2 W Z <br />J o <br />1 <br />i x i <br />d <br />M i <br />1 16 ■ <br />0 <br />1 � � <br />mp EW <br />1 <br />^gY0' <br />1 � <br />oI 3 3 <br />;rti w 1 <br />i.................r <br />REVISIONS <br />NO.. DATE DESCRIPTIIX4 <br />SWO3 FOR APPROVAL <br />Al <br />4. <br />DRAWN BY <br />L BEAR <br />WSFP PROJECT NUMBER <br />KG3516 <br />PRINT DATE <br />05/04/23 <br />SYMBOLLEGEND <br />�- -INDICATES A HANGER <br />-1- -INDICATES GROOVED COUPLING <br />'I', -INDICATES HYDRAULIC NODE TAG <br />xx'.zx" -INDICATES ELEVATION (CENTERLINE) <br />.� -INDICATES 4-WAY SEISMIC BRACE <br />-INDICATES LATERAL LONGITUDINAL BRACE <br />-INDICATES HANGERAND LINE RESTRAINT <br />N -INDICATES FLEX HOSE <br />-INDICATES ADDED SPRINKLER <br />OR -INDICATES RELOCATED SPRINKLER <br />-INDICATES PLUGGED SPRINKLER <br />PMT-INDICATES MECHANICAL TEE <br />- -INDICATES PIPE TO BE DEMOLISHED <br />FHw -INDICATES FULL HEIGHT WALL <br />O <br />y <br />PERMIT <br />DOCUMENTS <br />PROJECT <br />HELION ENERGY <br />CONTROL ROOM T.I. <br />1415 75TH STREET SW <br />EVERETT, WA 98203 <br />SHEET DESCRIPTION <br />FIRE PROTECTION <br />FP-01 <br />