Laserfiche WebLink
PROJECT INFORMATION <br />D <br />FIRE SPRINKLER PIPING PLAN <br />2 0 4 6 <br />SCALE Ire• =r-D• <br />Sprinkler1 1 Totale <br />STEEL SAMMY SIDEWINDER <br />ZEEPURUN <br />SAMMY SIDEWINDER <br />ALL THREAD ROD <br />SWIW?L RING- ryry%%ir <br />PIPE <br />STEEL SAMMY SIDEWINDER <br />ZEEPURUN <br />SAMMY SIDEWINDER <br />ALL THREAD ROD <br />SWIW?L RING- ryry%%ir <br />PIPE <br />CONTROL ROOM <br />ill" PLYWOOD SH <br />I4" METAL JOIST <br />8"ACOUSTICAL It <br />T <br />R <br />'P <br />aqi <br />q <br />HANGER SPACING - STEEL PIPE <br />FLEXIBLE DROP TO SPRINKLER <br />SIZE OF PIPE <br />MAXHANGER <br />WEIGHT OF WATER <br />NOTE: <br />SUPPORTED <br />SPACING <br />FILLED PIPE <br />BRANCHUNE 48"FLEXIBLE DROP LENGTH <br />1"(Sch 40) <br />12'-0 <br />2.051beIR <br />MAX NUMBER OF BENDS =6 <br />T MIN RADIUS =2"(UL) I7"(FM) <br />�1 � 22'.0 EQUIVALENT LENGTH <br />1 114"(Sch 40) <br />12'-0 <br />2.931be1R <br />1 1/2" (Sch 10) <br />15'-0 <br />3.041bs#t <br />FLEXIBLE DROP <br />2" (Sch 10) <br />15'-0 <br />4.221bs#t <br />MOUNTING BRACKET <br />2 112"(Sch 10) <br />15'-0 <br />5.891bsRt <br />CEILING <br />3" (Sch 10) <br />15'.0 <br />7.941beIR <br />- <br />SEMI RECESSED <br />4" (Sch 10) <br />15'-0 <br />11.781bsfl1 <br />SPRINKLER <br />6" (Sch 10) <br />15'-0 <br />23.031b.41 <br />BLDG SECTION <br />0 0 2 4 <br />1 <br />SCALE 1/4'= t'-0' <br />A <br />O <br />O Z' <br />2� <br />2 <br />`9 <br />� 00 <br />2 3 ,Z <br />Oc' <br />TIE-IN DETAIL <br />AREA OF WORK <br />- <br />t [BEE ®Ei�_.: - <br />D ASSEMBLV: <br />ETHING <br />RAMING @ 16" OC <br />WI-ATION <br />OWNER <br />EVERETT TECHNICAL PARK II LLC <br />12201 TUKWILLA INTERNATIONAL BLVD, <br />FLOOR <br />SEATTLE, WA 98168 <br />TENANT: <br />HELION ENERGY INCORPORATED <br />PROPERTY TAX NO: <br />28041100101000 <br />BUILDING INFORMATION <br />TYPE OF CONSTRUCTION. III-B <br />OCCUPANCY CLASSIFICATION: B/F-1 <br />SEISMIC DESIGN CATEGORY: D <br />CODE REFERENCES <br />NFPA 132019 EDITION <br />GENERAL PROJECT DESCRIPTION <br />MODIFY AND EXTEND THE EXISTING FIRE SPRINKLER SYSTEM <br />TO PROVIDE ADEQUATE FIRE PROTECTION FOR THE NEW <br />CONTROL ROOM ADDITION. <br />DESIGN CRITERIA <br />EXISTING ROOF LEVEL FIRE SPRINKLER SYSTEM <br />TO REMAIN AS IS- ESFR <br />NEW CONTROL ROOM FIRE SPRINKLER SYSTEM <br />LIGHT HAZARD .10 GPM / SQ. FT. <br />GENERAL NOTES <br />1. THREADED PIPE TO BE SCHEDULE 40 REGARDLESS OF SIZE. <br />2. ROLL GROOVED PIPE TO BE SCHEDULE 10 REGARDLESS OF <br />SIZE. <br />3. DRY SYSTEM PIPE TO BE BLACK, C FACTOR =100 PER NFPA <br />13 REQUIREMENTS. <br />4. ALL PIPING SHALL BE TESTED AT 200 PSI OR 50 PSI IN <br />EXCESS OF SYSTEM WORKING PRESSURE, WHICHEVER IS <br />GREATER. <br />5. EARTHQUAKE BRACING TO BE PROVIDED IN ACCORDANCE <br />WITH NFPA 13. <br />6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, <br />SHALL BE IN ACCORDANCE WITH NFPA 13. <br />7. ALL COMPONENTS SHALL BE ILL LISTED / FM APPROVED. <br />8. ALL ELECTRICAL WIRING SHALL BE PERFORMED BY OTHERS. <br />9. ALL FLFXHOSES TO BE VICTAULIC AH2 EITHER 48. OR 72' IN <br />LENGTH. <br />10. ALL HANGERS TO BE IN ACCORDANCE WITH NFPA 13. <br />11. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT <br />THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE <br />OWNER AND THEIR STRUCTURAL REPRESENTATIVE. <br />12. EXCEPT AS NOTED BELOW, ALL AREAS WHERE WET <br />PIPING IS PRESENT MUST BE HEATED OR INSULATED TO <br />MAINTAIN A MINIMUM OF 40°F. WHERE WET PIPING IS PRESENT <br />IN EXTERIOR WALLS FEEDING DRY SIDEWALL SPRINKLER <br />HEADS ON BALCONIES AND OTHER EXTERIOR SPACES, THE <br />FOLLOWING SHALL APPLY. (1) ALL PENETRATIONS THROUGH <br />THE EXTERIOR WALLS FOR THE DRY BARREL HEADS MUST BE <br />PROPERLY SEALED; (2) THE SPACE BETWEEN THE PIPING AND <br />THE EXTERIOR WALL INSIDE THE CAVITY MUST BE PROPERLY <br />INSULATED; (3) THE PIPE MUST NOT BE EMBEDDED IN THE <br />INSULATION; (4) NO INSULATION MUST BE PLACED BETWEEN <br />THE PIPING AND THE INTERIOR WALL; (5) THE TEMPERATURE <br />OF THE INTERIOR SPACE MUSE BE MAINTAINED AT MINIMUM <br />OF 60°F. <br />13. OWNER IS RESPONSIBLE FOR ALL MAINTENANCE AND <br />PROTECTION OF THE FIRE SPRINKLER SYSTEM(S). <br />14. PAINTING OF SPRINKLER PIPE AND PROTECTION OF PIPE <br />FROM PAINT OR CONSTRUCTION ACTIVITIES (SUCH AS FIRE <br />PROOFING) IS BY OTHERS AND EXCLUDED FROM THIS <br />CONTRACT. <br />15. THE FIRE SPRINKLER SYSTEMS SHALL BE MONITORED 24 <br />HOURS A DAY BY A CENTRAL STATION AND IS EXCLUDED <br />FROM THIS CONTRACT. <br />16, PER NFPA 132019 ED SECTION 16.2.7.5- A SUPPLY OF: (12) <br />SPARE SPRINKLERS, (1) SPRINKLER WRENCH AS SPECIFIED <br />BY THE MANUFACTURER FOR EACH TYPE OF SPRINKLER AND <br />A COMPLETE LIST OF ALL SPRINKLERS INSTALLED SHALL BE <br />LEFT IN THE SPRINKLER HEAD BOX AFTER PROJECT <br />COMPLETION. SPRINKLERS SHALL CORRESPOND TO THE <br />TYPES AND TEMPERATURES INSTALLED IN THE PROPERTY. <br />%116 Fire PrD States <br />lllll Fire Protection Co <br />t7*9 �r c aw.l ikepoua <br />14690 NE 957H ST, UNIT 101 <br />REDMOND, WA 98052 <br />TEL. 425.881.0100 <br />W W W.WSFP.COM <br />STATE LICENSE #WESTESF785LH <br />OWNERSHIP OF DOCUMENTS <br />..................7 <br />1 <br />ai11O <br />� � 1 <br />W <br />I Q y J <br />1 <br />I zO Z <br />U <br />1 <br />Z <br />1 U � <br />1 <br />1 2 W Z <br />J o <br />1 <br />i x i <br />d <br />M i <br />1 16 ■ <br />0 <br />1 � � <br />mp EW <br />1 <br />^gY0' <br />1 � <br />oI 3 3 <br />;rti w 1 <br />i.................r <br />REVISIONS <br />NO.. DATE DESCRIPTIIX4 <br />SWO3 FOR APPROVAL <br />Al <br />4. <br />DRAWN BY <br />L BEAR <br />WSFP PROJECT NUMBER <br />KG3516 <br />PRINT DATE <br />05/04/23 <br />SYMBOLLEGEND <br />�- -INDICATES A HANGER <br />-1- -INDICATES GROOVED COUPLING <br />'I', -INDICATES HYDRAULIC NODE TAG <br />xx'.zx" -INDICATES ELEVATION (CENTERLINE) <br />.� -INDICATES 4-WAY SEISMIC BRACE <br />-INDICATES LATERAL LONGITUDINAL BRACE <br />-INDICATES HANGERAND LINE RESTRAINT <br />N -INDICATES FLEX HOSE <br />-INDICATES ADDED SPRINKLER <br />OR -INDICATES RELOCATED SPRINKLER <br />-INDICATES PLUGGED SPRINKLER <br />PMT-INDICATES MECHANICAL TEE <br />- -INDICATES PIPE TO BE DEMOLISHED <br />FHw -INDICATES FULL HEIGHT WALL <br />O <br />y <br />PERMIT <br />DOCUMENTS <br />PROJECT <br />HELION ENERGY <br />CONTROL ROOM T.I. <br />1415 75TH STREET SW <br />EVERETT, WA 98203 <br />SHEET DESCRIPTION <br />FIRE PROTECTION <br />FP-01 <br />