A B I C D E I F G I H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> •- f ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> h• <br /> t THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> THE MULTIWIRE BRANCH CIRCUIT WILL <br /> AUTHORITY HAVING JURISDICTION, WHICH <br /> _ t. 4.; BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. <br /> y - 4:; • * (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> *' 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> LABORATORY SHALL LIST ALL OF WORK. <br /> 10 '�� ► EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> c� �t ".0 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> 6 STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> ,I pip S � INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> a + '~e' i0im ✓. " 1 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING <br /> AT THE UL-LISTED LOCATION PROVIDED INVERTER. <br /> BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF <br /> �• ti } UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. <br /> _ f • `, 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> / GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> • ;, N AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> M <br /> �. '. 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. L•,, <br /> CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH <br /> RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> 690.47. (IBC) <br /> �wOR JONV 9. ALL ELECTRICAL WORK TO BE IN <br /> WAs,yCOMPLIANCE WITH THE NATIONAL <br /> ELECTRIC CODE (NEC). <br /> 201148 8 <br /> rr%f FSSFGIs N�\� <br /> ms's <br /> f -J IONAUE <br /> 09/19/2023 <br /> STRUCTURAL ONLY <br /> - SHEET INDEX <br /> j <br /> PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> Lo PV 2 SITE PLAN PV 6 PLACARD Ul <br /> PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> PV 4 CHIKO MOUNTING <br /> CONFIDENTIAL-THE INFORMATION CONTAINED DRAWN BY: <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Kevin L N o I I ette DATE: EAC DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> SO L E N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5715 BEDFORD ST, 19/09/2023 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 5310 33rd Ave W Everett WA 98203 PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 1 <br /> CONSENT FROM SOLGEN POWER. <br />
The URL can be used to link to this page
Your browser does not support the video tag.