Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> 4/6/2023 4/6/2023 ELEC 10-FINAL STEVE BANKS CORRECTION <br /> REQUIRED <br /> Notes: <br /> JOSH 425-948-3614 <br /> JOSH@NORDICFORTHEHOME.COM <br /> Provide GFCI protection to the disposal,laundry and the outside receptacles.Provide AFCI protection to the washing machine and disposal,.The <br /> disposal breaker appears to be nonfunctional,it does not trip.Provide GFCI protection for the dryer circuit. Provide access to meeter for a visual <br /> inspection. Provide emergency disconnect label outside on the disconnect.Install label denoting generator as required per NEC 702.7. <br /> 5/9/2023 5/9/2023 ELEC 10-FINAL STEVE BANKS APPRVD-PERMIT as noted <br /> FINAL <br /> Notes: <br /> JOSH 425-948-3614 <br /> JOSH@NORDICFORTHEHOME.COM <br /> Contractor installing GFCI at the front porch by the front door. <br /> 5/9/2023 5/9/2023 ELEC 05-SERVICE STEVE BANKS APPROVAL <br /> Notes: <br /> I <br /> Printed:Wednesday, 10 May, 2023 2 of 2 rk <br /> SUPERION <br />