i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> 9/15/2022 9/15/2022 ELEC 06-ROUGH IN I STEVE BANKS I NOT READY <br /> Notes: <br /> PER MARIA,LOCK BOX CODE#0223 <br /> DANIEL 206-960-2397 <br /> info@mogovol.com <br /> Get your plumbing and mechanical rough in approved prior to electrical Rough in inspection.Metal sewer is not bonded you cannot re-ground the <br /> ground conductor in the subpanel it must be done in the service only.Nail plates missing especially where notching has been done outside and <br /> anywhere the cable is secured or drilled less than an inch and a quarter from the edge of the drywall service. Provide a ladder for inspection of the attic. <br /> Ground all metal boxes.You cannot staple NM cable on its edge.You must bury the grounding electrode conductor is 1 foot deep or more. <br /> 9/15/2022 9/15/2022 ELEC 05-SERVICE I STEVE BANKS I NOT READY <br /> Notes: <br /> DANIEL 206-960-2397 <br /> info@mogovol.com <br /> PER MARIA,LOCK BOX CODE#0223 <br /> DANIEL 206-960-2397 <br /> info@mogovol.com <br /> Install grounding electrode system to the service And ground grounded conductor in the service. <br /> 9/28/2022 9/28/2022 ELEC 06-ROUGH IN I STEVE BANKS I NOT READY eTRAKiT Inspection Request <br /> Notes: <br /> 9/27/2022 9:23 AM BRIGHT&RIGHT ELECT SRVS LLC <br /> KEYBOX CODE 0223 <br /> Contact Name:BRIGHT&RIGHT ELECT SRVS LLC <br /> Site Address:4505 CRESCENT AVE <br /> Phone:2069602397 <br /> e-Mail:brightandright@yahoo.com <br /> Replace all conductors that have been wet,especially the home runs above the panel. Raise all junction boxes above the insulation line in the attic per <br /> WAC 296-46B-314.001(1). <br /> 9/28/2022 9/28/2022 ELEC 05 SERVICE STEVE BANKS NOT READY eTRAKiT Inspection Request <br /> Notes: <br /> 9/27/2022 9:23 AM BRIGHT&RIGHT ELECT SRVS LLC <br /> KEYBOX CODE 0223 <br /> Contact Name:BRIGHT&RIGHT ELECT SRVS LLC <br /> Site Address:4505 CRESCENT AVE <br /> Phone:2069602397 <br /> e-Mail:brightandright@yahoo.com <br /> Previous corrections not completed. Meter disconnect is listed for use"suitable only for use as service equipment only".It cannot be used as installed in <br /> any jurisdiction as it would not comply with its listing. <br /> 10/6/2022 10/6/2022 ELEC 06-ROUGH IN STEVE BANKS APPROVAL see notes <br /> Notes: <br /> 10/4/2022 3:54 PM BRIGHT&RIGHT ELECT SRVS LLC <br /> key box code 0223 <br /> Contact Name:BRIGHT&RIGHT ELECT SRVS LLC <br /> Site Address:4505 CRESCENT AVE <br /> Phone:2069602397 <br /> e-Mail:brightandright@yahoo.com <br /> OK Rough in,all home runs are new. <br /> I <br /> Printed: Friday, 21 April,2023 2 of 3 rk <br /> SUPERION <br />