My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-53 2023-12-06
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-53
>
3003 W CASINO RD BLDG 40-53 2023-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 2:37:12 PM
Creation date
10/13/2023 6:28:22 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-53
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8 8 5 g 9 5 LEGEND <br /> SEE SHEET EO FOR LEGEND AND ABBREVIATIONS <br /> MATCH LINE FOR CONTINUATION SEE 1E267 <br /> x x x x x �0 <br /> I I <br /> A <br /> GENERAL NOTES <br /> 40-53 FACP MONITORING POINTS <br /> GAYLORD PNL FA LXXX <br /> GAYLORD PNL TRBL LXXX <br /> x <br /> 1118 <br /> I I <br /> x <br /> PNEU TEST <br /> 1417 7x <br /> REFERENCE DRAWINGS <br /> E517 FIRE ALARM SYSTEM DETAILS <br /> w w <br /> E517-1 FIRE ALARM RISER DIAGRAM <br /> 0 0 <br /> Q <br /> z z <br /> z " z <br /> o I I o <br /> 0- D' <br /> o x o <br /> I I <br /> w CAL-CERT w <br /> Z PHYSICAL FORCE <br /> 1617 CONSTRUCTION NOTES <br /> ELFCV- TRANSFER MONITORING OF GAYLORD PANEL FROM <br /> RM - - - - - - - - - - 40-30 FIRE ALARM PANEL TO NEW BUILDING 40-53 <br /> 11J8 11J8 FACP. PROVIDE CONDUIT, CONDUCTORS AND JUNCTION <br /> BOX TO INTERCEPT EXISTING CIRCUIT AS SHOWN. <br /> PROVIDE TAMPER SWITCH ON EXISTING VALVE. PROVIDE <br /> CONDUIT, CONDUCTORS AND CONNECTION TO NEW <br /> BUILDING FACP. <br /> CAL-C RT <br /> OXYG N PROVIDE MONITORING DEVICES ON EXISTING SPRINKLER <br /> 13JE 13J8 RISER. CONNECT TO NEW BUILDING FACP, UTILIZE <br /> EXISTING INFRASTRUCTURE. PROVIDE CONDUIT AND <br /> CONDUCTORS AS REQUIRED. SEE DETAIL 1/E517 FOR <br /> 14J8 INSTALLATION NOTES. <br /> CAL—CERT <br /> FLOW- RESS CAL-CERT <br /> 4J PHYSICAL FORCE GAYLORD PANEL <br /> 12J8 ALARM SIGNAL <br /> L 1:037 <br /> 1 TROUBLE SIGNAL <br /> 12J8 L1:038 <br /> SV53-1 A <br /> 3/4"C WF PRESSURE <br /> L 1:002 <br /> SV53-1 I <br /> 1 WE ISO TAMP R FPD SV53-1 TAMPER-C:� <br /> L1:003 L1:001 <br /> vs <br /> _-- — 6.5 9.5 11� <br /> MATCH LINE — FOR CONTINUATION SEE BLDG. 40-021 A <br /> 1E260 1E261 1E262 <br /> C.5 <br /> 1E263 1E264 1E265 <br /> 1E266 1E267 1E268 <br /> PARTIAL PLAN VIEW H.5 <br /> NNN 1E269 1E270 1E271 <br /> / SCALE: 1/8" = 1'-0" K <br /> KEY PLAN BLDG. 40KEY PLAN BLDG. 40-053 <br /> SCALE:NONE w <br /> 8 4' 0 4' 8' 16' <br /> SCALE: 1/8"-1'-0" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN AIL SUBTITLE CURRENT REVISION I SYMBOL DATE <br /> A EVERETT FIRE PANEL REPLACEMENT- IFC W2640474 SAZAN/ZO 11.14.22 THIS DESIGN AND/OR CHECKED FIRE ALARM SYSTEM PLAN-FIRST FLOOR 29824575 B 6.20.23 <br /> ` Sp <br /> ECIFICATION IS APPROVED SHEET SEQUENCE NO. <br /> BOE�HG NIN EVERETT FIRE PANEL REPLACEMENT 1 E 2 7 0 <br /> B SHOP DRAWINGS 29824575 AGOW/JS 6.19.23 (((TTT APPROVED By DEPT. DATE <br /> CHECKED <br /> ami APPROVED BUILDING 40-053 <br /> « nm mom.„u,z APPROVED ELECTRICAL MASTER COL. H.5-K/8-9.5 EVERETT, WA DWG NO. 40-053-1E270 <br />
The URL can be used to link to this page
Your browser does not support the video tag.