My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7730 GRANT DR 2023-10-25
>
Address Records
>
GRANT DR
>
7730
>
7730 GRANT DR 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 8:54:17 AM
Creation date
10/18/2023 9:30:17 AM
Metadata
Fields
Template:
Address Document
Street Name
GRANT DR
Street Number
7730
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
making solar simple, <br />EZf SOLAR <br />JB-1.2 EZfSOLAR <br />Specification Sheet making solar slmplo, <br />PV Junction Box for Composition/Asphalt Shingle Roofs <br />A. System Specifications and Ratings <br />• Maximum Voltage: 1,000 Volts <br />• Maximum Current: 80 Amps <br />• Allowable Wire: 14 AWG — 6 AWG <br />• Spacing: Please maintain a spacing of at least'/2" between uninsulated live parts and fittings for <br />conduit, armored cable, and uninsulated live parts of opposite polarity. <br />• Enclosure Rating: Type 3R <br />• Roof Slope Range: 2.5 — 12:12 <br />• Max Side Wall Fitting Size: 1" <br />• Max Floor Pass -Through Fitting Size: 1" <br />• Ambient Operating Conditions: (-35°C) - (+75°C) <br />• Compliance: <br />- JB-1.2: UL1741 <br />-Approved wire connectors: must conform to UL1741 <br />• System Marking: Interek Symbol and File #5019942 <br />• Periodic Re -inspections: If re -inspections yield loose components, loose fasteners, or any corrosion <br />between components, components that are found to be affected are to be replaced immediately. <br />Table 1: Typical Wire Size, Torque Loads and Ratings <br />1 Catductor <br />2 Conductor <br />Torque <br />Type NM hxh Lbs Voltage Current <br />ABB ZS6 terminal block <br />10-24 awg <br />16-24 awg <br />Sol/Str <br />0.".7 <br />6.2-8.8S <br />600V <br />30 amp <br />ABB ZS30 terminal block <br />6.24 awg <br />12 -20 aw <br />Sol/Str <br />1.0-1.6 <br />9.85-14.16 <br />600V <br />40 am <br />ABB ZS16 terminal bock <br />4.24 awl, <br />10-20 awg <br />Soi/Str <br />1.6-2.4 <br />14.6-21.24 <br />600V <br />60 am <br />ABB M6/8 terminal block <br />8.22 awg <br />Sol/Str <br />.08-1 <br />8.85 <br />600V <br />50 amp <br />Ideal452 Red WING -NUT Wire <br />Connector <br />8-I8 awg <br />Sol/Str <br />Self Torque <br />SelfTorque <br />600V <br />Ideal 451 Yellow WING -NUT <br />Wire Connector <br />1018awg <br />Sal/Str <br />Self Torque <br />Sdiiorque <br />600V <br />Ideal, In-SurePush4n <br />Connector Part #39 <br />10.14 awg <br />Sol/Str <br />Self Torque <br />Self Torque <br />600V <br />WAGO, 2204-1201 <br />10-20 awg <br />16 24 awg <br />Sol/Str <br />I Self Torque <br />WfTorquel <br />600V <br />1 Wimp <br />WAGO,221-612 <br />10-20 awg <br />10-24awg <br />Sol/Str <br />SeIfTorque <br />Sell Torque <br />600V <br />30amp <br />DottieDRC7S <br />6-12 awg <br />Sol/Str <br />Snap -In <br />Snapdn <br />ESP NG-53 <br />4-6 awg <br />Sol/silt <br />4S <br />2000V <br />10.14 awg <br />Sol/Sir <br />35 <br />ESP NG-717 <br />4,6 awg <br />Sol/Str <br />45 <br />2000V <br />10,14aft <br />Sol/Str <br />35 <br />Brumall4-5,3 <br />4-6awl <br />Sul/Str <br />45 <br />2000V <br />10 14 awg <br />Sol/Str <br />35 <br />Table 2: Minimum wire -bending space for conductors through a wall opposite terminals in mm (inches) <br />Wire size, AWG or <br />Wires per terminal (pole) <br />1 <br />2 <br />3 <br />4 or More <br />kcmil (mm2) <br />mm (inch) <br />mm (inch) <br />mm (inch) <br />mm (inch) <br />14-10 (2.1-5.3) <br />Not specified <br />- <br />- <br />8 (8.4) <br />38.1 (1-1/2) <br />6 (13.3) <br />1 50.8 (2) <br />ITEM NO. <br />PART NUMBER <br />DESCRIPTION <br />OTY <br />1 <br />JB-12 BODY <br />POLYCARBONATE <br />1 <br />WITH UV INHIBITORS <br />POLYCARBONATE <br />2 <br />JB-1.2 LID <br />WITH UV INHIBITORS <br />1 <br />3 <br />#10 X 1-114" PHILLIPS <br />6 <br />PAN HEAD SCREW <br />4 <br />#8 X 3/4" PHILLIPS <br />PAN HEAD SCREW <br />6 <br />I 1 .e 1*• <br />1279.68mm] [276.30mm] <br />I I.01 in 10.88in EZ /Z <br />SOLAR <br />J6-12 <br />i <br />(183.06mm] <br />7.21in <br />[265.18mm] <br />10.44in <br />PHONE:385-202-4150 <br />WWW.EZSOLARPRODUCTS.COM <br />SIZE <br />B <br />DWG. NO <br />JB-1.2 <br />REV <br />SCALE:1:2 <br />WEIGHT:1.45 LBS <br />SHEET 1 OF 3 <br />TORQUE SPECIFICATION: <br />15-20 LBS <br />UL STANDARD 1741, <br />CERTIFICATION: <br />NEMA 3R <br />WEIGHT: <br />1.45 LBS <br />*1� <br />BLUE RAVEN <br />1403 N. Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W.BLUERAVENSOLAR.COM <br />CONFIDENTIAL- THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NABCEP <br />CERTIFIED <br />PV INSTALLATION <br />PROFESSIONAL <br />Scott Gurney <br />#PV-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OPS <br />385-498-6700 <br />(DRAWING BY: <br />172.53mm <br />2.86in PLOT DATE: <br />PROJECT NUMBER: <br />SPEC SHEET <br />EZtSOLAR <br />PHONE: 385-202-4150 1 WWW.FZSOLARPRODUCTS.COM <br />PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTY OF EZ SOLAR. <br />ANY REPRODUCTION IN PARTOR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. <br />REVISION: PAGE NUMBER: <br />---- SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.