Laserfiche WebLink
A B I C D E I F G I H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> ' x R 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> ' 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> • r� THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH <br /> BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. <br /> y (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> = 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> • LABORATORY SHALL LIST ALL <br /> OF WORK. <br /> EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> cli 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> ' STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> +� INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING <br /> •`s ` ;_ > �; �4 i AT THE UL-LISTED LOCATION PROVIDED INVERTER. <br /> BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF <br /> UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. <br /> 1 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> ` SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> ' AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> M <br /> � 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. Lo <br /> CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH <br /> RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> _ 690.47. (IBC) <br /> 9. ALL ELECTRICAL WORK TO BE IN <br /> - <br /> �,-_- _ woR JoN <br /> ,. ��oF WASHY FS COMPLIANCE WITH THE NATIONAL <br /> ELECTRIC CODE (NEC). <br /> :20114868 Q7 <br /> sf •� ` t s r - a: F REGIS \� <br /> Y _ • - ; SS/ONALEN� <br /> t _ <br /> 07/12/2021 <br /> -_ - - STRUCTURAL ONLY <br /> SHEET INDEX <br /> PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> PV 2 SITE PLAN PV 6 PLACARD <br /> - ' - PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> _ PV 4 CHIKO MOUNTING <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED ARM CUSTOM <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Dale H a m i Ito nDATE: DESIGN <br /> �• ^ SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> O LG <br /> (v' C ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 7/9/2021 <br /> ` <br /> .•. SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E THE RECIPIENT'S ORGANIZATION, EXCEPT IN <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 1915 - 122nd PL SE, Everett, WA 98208 PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 1 <br /> CONSENT FROM SOLGEN POWER. <br />