A B I C D E I F G I H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> ~ 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH <br /> BE IDENTIFIED BY PHASE AND SYSTEM. <br /> SUPERSEDED THE NEC. <br /> t (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> LABORATORY SHALL LIST ALL OF WORK. <br /> EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> N - : _ <br /> 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> -= 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING <br /> AT THE UL-LISTED LOCATION PROVIDED INVERTER. <br /> y BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF <br /> UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. <br /> 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> * AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> co <br /> ru 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. L,,, <br /> CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH <br /> RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> 690.47. (IBC) <br /> \jOR JON 9. ALL ELECTRICAL WORK TO BE IN <br /> WAsLy FS COMPLIANCE WITH THE NATIONAL <br /> ELECTRIC CODE (NEC). <br /> _ cl) <br /> t <br /> • �- — 201148 8 <br /> FS,RFGIs Nom\ <br /> _ -- A 3/10/2021 <br /> - - - - STRUCTURAL ONLY <br /> F. <br /> SHEET INDEX <br /> F I <br /> -- - = PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> �, PV 2 SITE PLAN PV 6 PLACARD U, <br /> PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> PV 4 CHIKO MOUNTING <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED KCS CUSTOM <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER Shannon Barron Smith DATE: <br /> SO L C N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 3/9/2021 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 910 91 st PL SW Everett, WA, 98204 PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 1 <br /> CONSENT FROM SOLGEN POWER. <br />