Seatronics, Inc. Boeing 787 JV . Aircraft Early Warning Fire Detection Systems Job: 111137 <br />Fire Alarm System Submittal Manual Section 1 <br />VESDA System Management Computer: <br />The VESDA System Management computer is located at the Boeing Fire & Security <br />Dispatch center. It provides a graphical user interface for real time display and control of <br />VESDA functions. The primary system display screen depicts all the aircraft positions in the <br />factory. Aircraft are shown in colors which indicate its current status with respect to the <br />VESDA system (green - normal, yellow - trouble, red - alarm, blue — isolate and white <br />outlined to indicate no airplane present ("Out of Service"). <br />Secondary control "pop-up" screens are activated by clicking on an airplane symbol. The <br />pop-up window provides the following control function selections: "Normal On", "Reset", <br />"Isolate", "Out Of Service" and "Acknowledge". <br />Manual Stations: <br />A Manual Station is provided at each VESDA Control Panel location for manual initiation of <br />an alarm. The Manual Station transmits alarms to the MFAP via an addressable interface <br />module located in the VESDA Control Panel. Activation of the Manual Station will <br />immediately shutdown power to that aircraft position and transmit alarm signals <br />Save Switch: <br />A power shutdown Save Switch is provided on the front door of the Vesda Control Panel for <br />each aircraft position. The Save Switch transmits the abort signal to the MFAP via an <br />addressable <br />interface module located in the VESDA Control Panel. If High Level smoke alarm is present <br />on the Vesda control unit, depressing the yellow mushroom pushbutton switch will reset the <br />power shutdown time delay back to 60 seconds and an amber lamp mounted directly above <br />the pushbutton will illuminate. If the pushbutton is released with the alarm still present, the <br />shutdown timer will restart at 60 seconds timing to shutdown. Depressing the Save Switch <br />with no alarms present will indicate a trouble at the MFAP. <br />Horn/Strobe: <br />A Horn/Strobe alarm indicating device is provided at each aircraft position mounted directly <br />above the VESDA Control Panel. This device operates whenever a High Level Smoke <br />alarm is initiated on the Vesda Control Unit or a Manual Station is activated. The <br />Horn/Strobe is silenced by depressing the "Alarm Silence" push-button located inside the <br />VESDA Control Panel. <br />Seatronics, Inc. PO BOX 1138 Auburn, WA 98001 253-939-6060 <br />