My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BASE FILE 2023-10-24
>
Address Records
>
W CASINO RD
>
3003
>
BASE FILE
>
3003 W CASINO RD BASE FILE 2023-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2023 2:19:14 PM
Creation date
10/20/2023 6:22:48 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EQUIPMENT LIST <br />SEE SYSTEM PLAN FOR <br />CONNECTOR <br />7 <br />J-BOX LOCATION FOR EACH <br />POSITION. <br />SEE SYSTEM PLAN FOR <br />LOCATIONS. <br />ENCL. IS 8"X8"x4" NEMA <br />TERMINAL <br />12. COLOR -RED. <br />BLOCK <br />TB1 <br />C- <br />A RD/BK RD/BK <br />A <br />RD <br />CONNECTOR <br />B WH/BK WH/BK <br />B <br />BK <br />RECEPTACLE <br />C GR/BK GR/BK <br />C <br />WH/BL <br />ON J-BOX <br />D BK BK <br />D <br />BL/WH <br />EXTERIOR. <br />E BL E BL <br />E <br />WH/OR <br />F OR/BK OR/BK <br />F <br />OR/WH <br />G WH WH <br />G <br />WH#1 <br />H RD RD <br />H <br />WH <br />J OR OR <br />J <br />WH#2 <br />K BL/BK BL/BK <br />K <br />BK#2 <br />L BK/WH BK/WH <br />L <br />BK#1 - - <br />E <br />A#1 <br />M GR GR <br />M <br />SHLD <br />SPARE <br />1 BK (SPARE) <br />GJ SPARE <br />12 <br />J-BOX <br />VESDA CABLE CONNECTOR <br />SCALE: NONE <br />EPS-R(x) <br />A <br />EMERGENCY POWER <br />M R <br />SHUTDOWN PANEL <br />+ <br />6 <br />PROVIDED <br />++ <br />- <br />COM <br />2 <br />A <br />BYOTHERS. <br />PANELS TYPICALLY <br />3 <br />1 EOLRA B <br />LOCATED ADJACENT OR <br />A <br />4 INPUT <br />470 <br />2#14 X X XXXX <br />NEAR VESDA CONTROL <br />PANELS FOR EACH <br />- B <br />5 CH #1 <br />120VAC CNTRL PWR PWR/FAULT <br />m m <br />POSITION. z i = 1 N5406 <br />8 <br />ACTIVATION CKT. SHUTDOWN SUPERVISION <br />7 <br />ACTIVATION MONITOR <br />- XTRI-R 6 <br />INPUT CONTACTS <br />SEE BOEING FPO PNL. 38 1 37 136 35 3 <br />A MONITOR CKT. I EOLR <br />470 <br />CONFIGURATION/WIRING <br />DRAWING FOR EACH EPS o + <br />A <br />M R <br />PWR SHTDN xxxx <br />PANEL FOR PROPER <br />MONITOR CKTS. AND ACTIVATED MONITOR <br />WIRING TERMINATION <br />+ 1 + COM <br />ACTIVATION CKT. A B <br />CONTACTS <br />DESIGNATIONS. PANEL <br />_ 2 _ <br />MUST BE IN <br />CONFIGURATION VARIES <br />3 <br />1 SEPARATE <br />BY POSITION. <br />A 4 INPUT <br />CONDUITS. <br />B 5 CH #1 <br />6 <br />8 <br />7 <br />_ <br />XTRI-R 6 <br />A MONITOR CKT. <br />EPS <br />PANELS - VESDA SYSTEM INTERFACE WIRING CONNECTIONS <br />SCALE: <br />NONE <br />9 <br />VESDA SYS. SMK. DIET. <br />- <br />AUD/VIS DEV. Q SEATRONICS. <br />TECH. TO <br />FIELD VERIFY LOCATION. <br />V SEE SYSTEM PLAN FOR <br />24" 9 REQUIRED LOCATIONS. <br />1 <br />MANUAL STATION - <br />MOUNT <br />ODERIGHT <br />\ /� <br />VGP o <br />EFT VCP. <br />aF <br />VESDA CONROL PNL. <br />24"W X 24"H X 8"D <br />70" <br />MIN <br />VPS <br />CONDUIT <br />MAX. <br />ENTTRYC <br />q VESDA POWER SUPPLY: <br />LOW VOLT. <br />0 <br />13.5."H x 13"W x 3"D <br />48" CONDUIT <br />:13" MIN. <br />BATT o <br />BATTERY ENCLOSURE: <br />12"H x 26"W x 9"D <br />6 5 <br />VESDA CONTROL PANEL <br />& ANCILLARY <br />EQUIPMENT <br />MOUNTING ELEVATIONS (TYP.) <br />(NO SCALE) <br />REVISION BY APPROVED DATE I SYM REVISION <br />BOEING 787 BUILD BACK PROJECT — TO 04/14/23 <br />B <br />A#2 <br />wH+ 5 � SMOKE BET. <br />SMKDET ABV. VCP <br />BK- 6 1b <br />9 <br />-NOTE: OR/WH VNET WIRE <br />PAIR IN CABLES ARE NOT <br />USED (SPARE). <br />B <br />B <br />A <br />A <br />A� <br />A� <br />2H <br />DESCRIPTION <br />VESDA CONTROL PANEL ASSY. <br />VESDA ALARM HORN -STROBE <br />VESDA POWER SUPPLY PANEL <br />BATTERY ENCLOSURE <br />BATTERIES, 12V, 55AH <br />FIRE ALARM MONITOR MODULE WITH RELAY <br />VESDA CONNECTOR JUNCTION BOX ASSY. <br />MANUAL PULL STATION, DOUBLE ACTION <br />SMOKE DETECTOR, PHOTELECTRIC <br />- TO NEXT VCP ON <br />VESDA NET COMS CKT. <br />VNET IN _ TO PREVIOUS VCP ON <br />VESDA NET COMS CKT. <br />OR CKT. ORIGIN AT VCE. <br />AP SLC OUT _ TO NEXT VCP ON MFAP <br />SLC COMS CKT. <br />MFAP SLC IN _ TO PREVIOUS VCP ON <br />VESDA NET COMS CKT. <br />OR CKT. ORIGIN AT MFAP. <br />WH BK VESDA MANUAL <br />STATION <br />DOUR <br />470 WH BK 8 <br />VESDA AUD/VIS DEV <br />ABOVE VCP. <br />ED <br />241, <br />2H <br />VCP <br />+ - + <br />33 1 32 1 31 1 30 129 28 27 1 26 1 25 24 23 I 22 1 21 1210 1 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 T BI <br />N C + N+ + L� L� + + <br />< m� <br />IFM-2 <br />G <br />PWR. SUP. SUPV. <br />WH BK <br />VESDA CONTROL PANEL (VCP) <br />TYP. 3 <br />VPS <br />AUX. POWER SUPPLY, 24VDC, 4 AMP, <br />3#10 TO BATTERIES ALTRONIX CORP. P/N AL4000LX <br />TO 120 VAC DED. CKT. 0 TEL <br />ON EMERG. PWR. <br />OAC z f m <br />ODc <br />E00 O BAT <br />B z <br />Kcz SE S 1 TO <br />T!! <br />� FORa o24V 0 E ATIONWH^ 5 SWl®BK4 OPEN(24V SELECT) O <br />B2 — J1 O <br />nc pL0 24VDC <br />4 2#14 +BAT OUT ALTRONIX <br />TB3 00 00 Tea POWER SUPPLY <br />2H <br />rBATTIERY <br />BATTERY A <br />BATTERY ENCLOSURE VESDA SYSTEM POWER SUPPLY <br />VESDA CONTROL- PANEL - SYSTEM INTERCONNECT WIRING DIAGRAM <br />BOEING 40-21 /22 BLDG. <br />SCALE: NONE <br />APPROVED <br />DATE <br />S E AT R O N I C S <br />FIRE PROTECTION SERVICES <br />PO BOX 1138 <br />AUBURN, WA 98071 <br />253-939-6060 <br />-PROPRIETARY- <br />THIS INFORMATION IS THE <br />THIS <br />OF SEATRONICS, <br />INC. AND SHALL NOT BE <br />UTILIZED OR DISCLOSED <br />WITHOUT WRHTEN <br />AUTHORIZATION FROM <br />SEATRONICS, INC. <br />PART NUMBER <br />MFG. <br />SEE DWG 110773-FA351 <br />SEATRONICS <br />MTH-MC-R <br />SIEMENS <br />AL400-ULX <br />ALTRONIX <br />CAB-BATT-R <br />SIEMENS <br />PS-12550 <br />POWERSONIC <br />XTRI-R <br />SIEMENS <br />SEE DWG 111009-FA315 <br />SEATRONICS <br />103-23 <br />GE <br />OP-921 <br />SIEMENS <br />DIAGRAM TYPICAL FOR: <br />40-21 VCP POS. 1, 2, 3, 4 & 6 <br />40-22 VCP POS. 4 <br />GENERAL NOTES <br />1. SEE DWG. 110773-FA101, 40-22 VESDA SYSTEM <br />ONELINE DRAWING. <br />2. SEE DWG. 110773-FA121, 40-21 VESDA SYSTEM <br />ONELINE DRAWING. <br />3. SEE DWG. 110773-FA201, 40-22 OVERALL VESDA <br />SYSTEM PLAN, FOR EQUIPMENT LOCATIONS. <br />4. SEE DWG. 110773-FA221, 40-21 OVERALL VESDA <br />SYSTEM PLAN, FOR EQUIPMENT LOCATIONS. <br />SEE DWG. 110773-FA306, 40-21/22 VESDA SYSTEM <br />MFAP, FOR SLC CKT. DETAILS DIAGRAM. <br />© SEE DWG. 110773-FA307, 40-21/22 VESDA <br />COMMUNICATIONS ENCLOSURE (VCE), FOR VESDA <br />NETWORK CKT. DETAILS DIAGRAM. <br />CONSTRUCTION NOTES <br />LOCATE FIRE ALARM MONITOR/RELAY INTERFACE <br />MODULES FOR EPS PANEL ACTIVATION AND <br />MONITORING WITH 3 FEET OF EPS PANEL. ACTIVATION <br />CIRCUIT MAY NOT BE IN THE SAME CONDUIT AS THE <br />MONITORING CIRCUITS. <br />120 VAC DEDICATED CKT. ON EMERGENCY POWER. <br />CIRCUIT BREAKER TO BE CLEARLY LABLED "FIRE <br />ALARM" NEXT TO BREAKER AND ON PANEL <br />SCHEDULE. CIRCUIT BREAKER SHALL BE FITTED WITH <br />AN ANTI -TAMPER DEVICE TO PREVENT ACCIDENTAL <br />OR INCIDENTAL TURN-OFF. CKT. SOURCE & <br />NUMBER TO BE LABELED ON PANEL FRONT. <br />3. NEW VESDA SYSTEM EQUIPMENT PROVIDED BY <br />SEATRONICS. EQUIPMENT IS TO BE MOUNTED <br />/INSTALLED BY BOEING ELECTRICAL CONTRACTOR AS <br />REQUIRED. NEW ELECTRICAL RACEWAY AND <br />CONDUCTORS PROVIDED AND INSTALLED BY <br />ELECTRICAL CONTRACTOR. <br />WIRE/CABLE LEGEND <br />NOTE: NO CABLE SUBSTITUTIONS WITHOUT APPROVAL <br />FROM SEATRONICS, INC. <br />A = CAROL WIRE C2534 OR BELDEN 9460, #18 AWG <br />SHEILDED TWISTED PAIR, STRANDED, JACKETED <br />CABLE (.205" OD) TYPE CM. <br />B - BELDEN P/N 3107A (RS485 COMMUNICATION <br />CABLE, 2 TWISTED SHEILDED PAIRS, 22 AWG, 120 <br />OHM IMPEDANCE) (.356" OD) <br />C - 2-#10 AWG THHN STRANDED, (RED & BLACK) <br />D = 2-#12 AWG THHN STRANDED (RED & BLACK) <br />E = CAROL WIRE P/N C2536A #16 AWG SHEILDED <br />TWISTED PAIR, STRANDED, JACKETED CABLE (.307" <br />OD) TYPE CM. <br />F = CABLE TYPE 'SOOW', 12-#16 AWG. CAROL 09612 <br />OR EQUAL (.70" NOM. OD) <br />G = NOT USED <br />H = #16 TEEN OR TEN STRANDED <br />CONTROL PANEL INTERCONNECT WIRING DIAGRAM <br />TITLE _ <br />BOEING 40-21/22 BLDG. <br />AIRCRAFT FIRE DETECTION SYSTEMS <br />XX-XX EVER <br />110773-FA308-0 <br />'.EVISION SYMBOL DATE <br />04/14/23 <br />FA308 <br />COMP N0. <br />110773-FA308-0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.