Laserfiche WebLink
System Components <br />A basic Cerberus PRO Modular fire - <br />alarm control panel (FACP) consists of <br />one (1) of the following parts: Operator <br />Interface; power supply (PSC-12); Class <br />X Device Loop Card (XDLC); Zone <br />Indicating Card (ZIC-4A); five -slot card <br />cage (CC-5); Inner Door Blank Single <br />Plate (ID-SP), and a CAB-1, CAB-2 or <br />CAB-3 system enclosures. <br />Optional modules that can be installed on <br />a Cerberus PRO Modular FACP include: <br />Card Cage (Model CC-2); Network Interface <br />Card (Model NIC-C); 8-Circuit Zone <br />Indicating Card (Models ZIC-813 I ZIC-2C); <br />Output Control Module (Model OCM-16); <br />Switch Control Module (Model SCM-8); <br />LED Control Module (Model LCM-8); Fan <br />Control Module (Model FCM-6); <br />Supervised Input Module (Model SIM-16); <br />Power Supply Extender (Model PSX-12); <br />Remote Network Interface (Model RNI); <br />Remote Printer Module (Model RPM); <br />System Status Display (Model SSD); Digital <br />Alarm Communicator (Model FCA2015- <br />U1) Multi -Point Digital Alarm <br />Communicator (Model MDACT); Two - <br />Module Remote Enclosure (Model <br />REMBOX2), and the Four -Module Remote <br />Enclosure (Model REMBOX4). <br />Additionally, Cerberus PRO Modular <br />panels are compatible with all of the <br />advanced Siemens field devices in <br />signaling appliances and intelligent, <br />addressable detection. <br />Cerberus DMS <br />Management Station Cerberus PRO <br />Modular <br />Cerberus DIMS Management Stations <br />compatible with Cerberus PRO Modular <br />Cerberus PRO Modular panels are <br />compatible with Siemens Fire Safety <br />Management Stations, which provide <br />integrated and reliable FACP monitoring <br />and control of system events — <br />including: 'Alarm' I 'Trouble' I 'Security' <br />'Supervisory' commands. <br />Cerberus DMS management stations <br />include PC -based, color -graphics <br />software designed for use with the <br />XNET network, offering full control and <br />annunciation. An extensive history log <br />of all system events, as well as <br />extensive report -generation capabilities, <br />is easily maintained. There are also <br />user -programmable electronic buttons <br />that allow for site -specific control <br />functions. <br />rrlow,7 I <br />44QQ <br />cerb.—a PRO Mods br O <br />0 <br />b d 0 <br />Operator Interface used on <br />Cerberus PRO Modular FACPs <br />FCM2041-U3 —> Operator Interface <br />The Operator Interface is the primary <br />user interface and central microprocessor <br />for Cerberus PRO Modular panel. <br />Enhancements to the most current <br />version of the Cerberus PRO Modular <br />Operator Interface include go -to - <br />beginning, go -to -end queue buttons; a <br />front-end command screen with 'Alarm' <br />'Supervisory' I 'Trouble' light -emitting <br />diodes (LEDs), and three (3) types of <br />alternate -language overlays all <br />orderable under one (1) part. <br />See: Details for Ordering section <br />in this document for more info). <br />Cerberus PRO Modular panels are <br />controlled and operated from the <br />Operator Interface, which uses large, <br />lighted control buttons to prompt the <br />end -user to the next available, correct <br />system operation shown on the front- <br />end screen. Additionally, the system <br />Operator Interface provides a 6" (15.2 <br />cm.) front-end touch screen comprised of <br />system -status LEDs as well as a liquid - <br />crystal display (LCD) of 1200 —x— 800. <br />There are language overlays that provide <br />naming in alternate languages for visual <br />indicators found on the front of each <br />Operator Interface. Each overlay is <br />assigned on the outer assembly, <br />respectively, when affixed to the front- <br />end display on the user interface. <br />The Operator Interface contains the site - <br />specific program configuration in the <br />software too, Zeus-C. <br />f.— <br />ZIC-4A —> Zone Indicating Card <br />The Zone Indicating Card (Model ZIC-4A) <br />provides four (4) fully supervised, <br />programmable output circuits <br />for use on each Modular FACP. <br />Model ZIC-4A supplies four (4). 'Class <br />B' (Style Y) or 'Class A' (Style Z)-type <br />output circuits, power limited to <br />3.OA, maximum, per circuit. <br />Each circuit can be independently <br />programmed for use with agency <br />listedlapproved audible or visual <br />notification appliances; emergency <br />audio speakers; municipal -tie boxes; <br />leased lines, or as optional releasing <br />circuits. Model ZIC-4A plugs into one <br />(1) slot in the Model CC-5 or CC-2 <br />card cage, and has on -board LEDs for <br />system status and troubleshooting. <br />Indication of power, communication, <br />internal operation and ground -fault <br />conditions are provided, as well as <br />indication of circuit activation or <br />'Trouble' conditions. <br />ZIC-8B —> Zone Indicating Card <br />(with Model ZIC-2C) <br />Another Zone Indicating Card (Model <br />ZIC-813) provides eight (8) fully <br />supervised, programmable output <br />circuits for use on Modular panels. <br />Model ZIC-8B contains eight (8) <br />'Class B' (Style Y)-type output <br />circuits, power limited to 2.OA, max., <br />per circuit. Each circuit can be <br />independently programmed for use <br />with agency-listed/approved audible <br />or visual notification appliances, or <br />emergency audio speakers. Model <br />ZIC-8B plugs into one (1) slot in the <br />Model CC-5 or CC-2 card cage, and <br />has on -board LEDs for system status. <br />A Model ZIC-2C mounts directly on <br />Model ZIC-813, and allows each <br />Model ZIC-813 output circuit to be <br />used for two -channel voice <br />applications. Indication of power, <br />communication, internal operation, <br />and ground -fault conditions are <br />provided, as well as indication of <br />circuit activation or 'Trouble' <br />conditions. <br />Siemens <br />Building Technologies Division -2- usa.siemens.comlcerberus-pro-modular <br />