My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BASE FILE 2023-10-24
>
Address Records
>
W CASINO RD
>
3003
>
BASE FILE
>
3003 W CASINO RD BASE FILE 2023-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2023 2:19:14 PM
Creation date
10/20/2023 6:22:48 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADAMm457OS <br />ADAMm4571 S <br />� rarusiao M.qS>.,, <br />♦ T�a��2in� eC �S <br />� rxi xlPo�rz'�ner� <br />1 aOlt <br />Dare Ga/eWY yr/!h S 42pjyS5 <br />// .iBClr(rtY <br />/ RS-412/oP5 � <br />'0ory1 <br />VS SND <br />FCC (E <br />Introduction <br />2-port isolated RS-422/485 to <br />Ethernet Data Gateway <br />1-port Isolated RS-422/485 to <br />Ethernet Data Gateway <br />Features <br />■ Supports 10/100 Base-T Ethernet <br />• 1,500 VRMs isolation for RS-422/485 port <br />■ Provides Host/Device Idle protection & auto -reconnection function to <br />enhance the reliability of system. <br />■ Supports multiple advanced security protections: Triple DES, IP address <br />control <br />■ Transmission speed up to 230 Kbps <br />• Remote download firmware: Easy to maintain <br />• Auto -detecting Configuration Utility <br />■ Easy -managing Port Mapping Utility <br />• Supports Windows° NT/2000/XP driver <br />■ Automatic RS-485 data flow control <br />The ADAM-4570S/4571S is an advanced security data gateway that works between RS-422/485 and Ethernet interfaces. It not only upgrades your existing RS-422/485 devices to <br />Ethernet, but also provides a quick and safe way to transmit important data via Ethernet. The ADAM-4570S/4571S is specially desi <br />for remotely controlling and monitoring mission critical application environments. <br />Advanced security features <br />Multiple advanced security features protect the system. T-DES (Triple Data Encryption Standard); IP address control and configuration. By using T-DES, you can key -in passwords <br />to secure your data. The data cannot be accessed by other host PCs unless the PC have the correct password. This prevents important data from being accessed by an unauthorized <br />users. IP address control can block access to a specific ADAM-4570S. It restricts the access right of up to 32 PCs at one time. In addition to these features, the ADAM-4570S/4571S <br />also protects all configuration settings from being changed inadvertently. When this option is enabled, only the corresponding PC can set the configuration. These functions were all <br />designed for data protection and security as well as overall system reliability. <br />Host/Device Communication Redundancy improves the reliability of the system (ADAM-4570S) <br />To improve the stability of systems the ADAM-4570S provides new powerful functions to help you create stable systems - fast. The <br />The purpose of the "Host idle" function is to prevent a system hang-up from occurring due to application program failure. If an application program fails, the ADAM-4570S will cut <br />off the connection between the host PC and the ADAM-4570S, so that another PC can start to access the same ADAM-4570S. Also, if the serial device or communication between <br />the device and the ADAM-4570S fails, the "Device Idle" function will switch the communication port from one port to another port to keep communication going with another device <br />automatically. Thus, another device can send data to the ADAM-4570S. <br />Auto -reconnect after networking recovers <br />The ADAM-4570S/4571S provides an "Auto -reconnect" function to solve networking breaks problem. When the ADAM-4570S/4571S is powered -off accidentally, the driver will <br />keep trying to reconnect the ADAM-4570S/4571S automatically. When the ADAM-4570S/4571S is powered -on again, through this auto -reconnect function, the host PC can send <br />commands to the ADAM-4570S/4571 S immediately. This function enhances the reliability of the system. <br />Specifications <br />• Protocol <br />TCP/IP <br />• Network <br />10/100Base-T Ethernet <br />• Port <br />1/2 Independent RS-422/485 ports <br />• Connector <br />Network: RJ-45 <br />Serial: RJ-48 (RJ-48 to DB-9 cable provided) <br />• Security <br />T-DES (FIPS PUB 46-2), IP address control <br />• Data Protection type <br />Host idle; device idle, auto -reconnection <br />• Transmission speed <br />50 bps —230 Kbps <br />• Isolation <br />1,500VRMs <br />• Parity bit <br />Odd, even, none, space, mark <br />• Data bit <br />5, 6, 7, 8 <br />• Stop bit <br />1,1.5, 2 <br />• Diagnostic LEDs <br />Network: Tx/Rx, Link, Speed (10/100 Mbps), Power <br />Serial: Tx/Rx, Status <br />• Driver Supported <br />• Power Requirements <br />• Power Consumption <br />• Mounting <br />• Operating Temperature <br />• Storage Temperature <br />• Operating Humidity <br />• Storage Humidity <br />Windows NT/2000/XP <br />Unregulated 10 to 30 Voc <br />3.3 Watt (ADAM-4571 S); 3.5 watt (ADAM-4570S) <br />DIN -rail, panel mounting, piggyback stack <br />0 — 60° C (32 --140° F) <br />-20 — 80° C (-4 --176° F) <br />20-95% (non -condensing) <br />0 -- 95% (non -condensing) <br />Ordering Information <br />• ADAM-4571S `-** 1-port Isolated RS-422/485 to Ethernet Data Gateway <br />w/Security (includes RJ48 to DB9 cable,1 m) <br />• ADAM-4570S 2-part Isolated RS-422/485 to Ethernet Data Gateway <br />(includes RJ48 to DB9 cable,1 m) <br />• Opt1A 100 cm RJ48 to male RS-232/422/485 cable <br />
The URL can be used to link to this page
Your browser does not support the video tag.