IDDEC Oiltight Switches & Pilot Devices o22mm - HW Series
<br />Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
<br />Approvals
<br />CSA: pushbuttons and selector switches: A600
<br />U` ®
<br />CCs
<br />Q
<br />pilot lights and illuminated pushbuttons, direct supply
<br />pilot lights and illuminated pushbuttons with integral transformer
<br />a
<br />(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
<br />File No. E68961 File No. LR92374 Certificate No.
<br />UL: pushbuttons and selector switches: A600
<br />pilot lights and illuminated pushbuttons, direct supply
<br />20050103051,15656
<br />pilot lights and illuminated pushbuttons with integral transformer
<br />C E
<br />(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
<br />TUV: pushbuttons and selector switches: A600=P600 (NO, NC)/0600 (NO-EM, NC -LB)
<br />TUV Rheinland
<br />pilot lights and illuminated pushbuttons, direct supply
<br />Registration No. R9551089 (E-stops)
<br />pilot lights and illuminated pushbuttons with integral transformer
<br />Registration No. J9551458 (all other switches)
<br />(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
<br />Registration No. J9650511 (Pilot Lights)
<br />Operating Temperature
<br />Operation: -25 to +50°C (without freezing), Storage: -40 to +70°C (without freezing)
<br />Vibration Resistance
<br />10 to 55Hz, 98m/sec2 (1013) conforming to IEC6068-2-6
<br />Shock Resistance
<br />980m/sec2 (100G) conforming to IEC6068-2-7
<br />Electric Shock Protection
<br />Class 0 conforming to IEC60536
<br />Degree of Protection
<br />IP65 (from front of the panel)
<br />(conforming to IEC60529)
<br />IP20 (Type HW-F contact block)
<br />(conforming to NEMA ICS6-110)
<br />NEMA 1, 2, 3, 311, 3S, 4, 4X, 5,12, 13 (from front of panel)
<br />Mechanical Life
<br />Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000
<br />Pollution Degree (conforming to IEC60947-1)
<br />3 for switches not using a transformer, 2 for switches using a transformer
<br />AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC -LB)
<br />Rated Operational Characteristics
<br />DC-13: P600 or Ue = 125V, le =1.1A (NO, NC)
<br />_
<br />DC-13: G600 or Ue = 125V, le = 0.9A (NO-EM, NC -LB)
<br />600V
<br />Rated Insulation Voltage
<br />Rated Switching Over -Voltage
<br />Less than 4kV, conforming to IEC60947-1
<br />Rated Impulse Withstanding Voltage
<br />4kV for contact circuit, 2.5kV for lamp circuit
<br />Rated Thermal Current
<br />10 Amp
<br />Minimum Switching Capacity
<br />5 mA at 3V AC/DC
<br />Contact Operation
<br />Slow break NC or NO, self-cleaning
<br />5.5mm to 10mm travel to latch
<br />Positive Action Operation
<br />45N minimum force to latch
<br />10mm maximum travel
<br />(Emergency Stops with NC contacts)
<br />1,800 operations per hour maximum for a Pushlock Turn Reset
<br />900 operations per hour maximum for a Push -Pull
<br />Flush and extended pushbuttons -with 1NO or 1NC contact: 6.2 2N (momentary), 7.0 2N (main -
<br />Operating Force
<br />tained)
<br />Additional contacts-1NO or INC: +3.2N (momentary), +3.3N (maintained)
<br />Terminal Referencing
<br />Conforming to CENELEC EN50005
<br />Recommended Terminal Torque
<br />0.8 N m (7.1 in lb.)
<br />External Short -Circuit Protection
<br />10A 250V fuse conforming to IEC60269-1
<br />Applicable Wire Size
<br />Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
<br />Contact Resistance
<br />Initial contact resistance of 50mQ or less
<br />Contact Gap
<br />4mm (NO and NC), 2mm (NO-EM and NC -LB)
<br />Horsepower Rating
<br />Reference Value: 1/4 HP @ 120V (10 non-reversing),1HP @ 240V (3o non -reversing)
<br />Electrical Reliability
<br />MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA)
<br />Lamp Ratings
<br />Incandescent: 1 W
<br />LEDs: 6V/17mA max,12V & 24V/11mA max, 120 & 240V/10mA max
<br />Maximum Inrush Current
<br />40 A (40 ms)
<br />Contact Material
<br />Silver (gold plated contacts available - contact IDEC)
<br />Contact Block
<br />Type HW-C/HW-F/HW-G
<br />Pushbuttons
<br />Illuminated Pushbuttons
<br />600V
<br />Rated Insulation Voltage
<br />Selector Switches
<br />10A
<br />Rated Continuous Current
<br />Illuminated Selector Switches
<br />Contact Ratings by Utilization Category
<br />Pushbutton Selectors
<br />AC-15 (A600)
<br />-
<br />IEC 60947-5-1
<br />DC-13(P600)
<br />Operational Voltage
<br />24V
<br />48V
<br />50V
<br />110V
<br />220V
<br />440V
<br />AC
<br />AC-12 Control of resistive loads & solid state loads
<br />10A
<br />-
<br />10A
<br />10A
<br />6A
<br />2A
<br />Operational
<br />50/60
<br />Hz
<br />AC-15 Control of electromagnetic loads (> 72VA)
<br />10A
<br />-
<br />7A
<br />5A
<br />3A
<br />1A
<br />Current
<br />DC-12 Control of resistive loads & solid state loads
<br />8A
<br />5A
<br />-
<br />2.2A
<br />1.1A
<br />-
<br />DC
<br />DC-13 Control of electromagnets
<br />5A
<br />2A
<br />-
<br />1.1A
<br />0.6A
<br />-
<br />1. For dimensions, see page A3-100.
<br />2. For life expectancy Berating curves, seepage A3-105.
<br />Tel
<br />t
<br />www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-53