Laserfiche WebLink
IDDEC Oiltight Switches & Pilot Devices o22mm - HW Series <br />Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 <br />Approvals <br />CSA: pushbuttons and selector switches: A600 <br />U` ® <br />CCs <br />Q <br />pilot lights and illuminated pushbuttons, direct supply <br />pilot lights and illuminated pushbuttons with integral transformer <br />a <br />(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) <br />File No. E68961 File No. LR92374 Certificate No. <br />UL: pushbuttons and selector switches: A600 <br />pilot lights and illuminated pushbuttons, direct supply <br />20050103051,15656 <br />pilot lights and illuminated pushbuttons with integral transformer <br />C E <br />(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) <br />TUV: pushbuttons and selector switches: A600=P600 (NO, NC)/0600 (NO-EM, NC -LB) <br />TUV Rheinland <br />pilot lights and illuminated pushbuttons, direct supply <br />Registration No. R9551089 (E-stops) <br />pilot lights and illuminated pushbuttons with integral transformer <br />Registration No. J9551458 (all other switches) <br />(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) <br />Registration No. J9650511 (Pilot Lights) <br />Operating Temperature <br />Operation: -25 to +50°C (without freezing), Storage: -40 to +70°C (without freezing) <br />Vibration Resistance <br />10 to 55Hz, 98m/sec2 (1013) conforming to IEC6068-2-6 <br />Shock Resistance <br />980m/sec2 (100G) conforming to IEC6068-2-7 <br />Electric Shock Protection <br />Class 0 conforming to IEC60536 <br />Degree of Protection <br />IP65 (from front of the panel) <br />(conforming to IEC60529) <br />IP20 (Type HW-F contact block) <br />(conforming to NEMA ICS6-110) <br />NEMA 1, 2, 3, 311, 3S, 4, 4X, 5,12, 13 (from front of panel) <br />Mechanical Life <br />Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000 <br />Pollution Degree (conforming to IEC60947-1) <br />3 for switches not using a transformer, 2 for switches using a transformer <br />AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC -LB) <br />Rated Operational Characteristics <br />DC-13: P600 or Ue = 125V, le =1.1A (NO, NC) <br />_ <br />DC-13: G600 or Ue = 125V, le = 0.9A (NO-EM, NC -LB) <br />600V <br />Rated Insulation Voltage <br />Rated Switching Over -Voltage <br />Less than 4kV, conforming to IEC60947-1 <br />Rated Impulse Withstanding Voltage <br />4kV for contact circuit, 2.5kV for lamp circuit <br />Rated Thermal Current <br />10 Amp <br />Minimum Switching Capacity <br />5 mA at 3V AC/DC <br />Contact Operation <br />Slow break NC or NO, self-cleaning <br />5.5mm to 10mm travel to latch <br />Positive Action Operation <br />45N minimum force to latch <br />10mm maximum travel <br />(Emergency Stops with NC contacts) <br />1,800 operations per hour maximum for a Pushlock Turn Reset <br />900 operations per hour maximum for a Push -Pull <br />Flush and extended pushbuttons -with 1NO or 1NC contact: 6.2 2N (momentary), 7.0 2N (main - <br />Operating Force <br />tained) <br />Additional contacts-1NO or INC: +3.2N (momentary), +3.3N (maintained) <br />Terminal Referencing <br />Conforming to CENELEC EN50005 <br />Recommended Terminal Torque <br />0.8 N m (7.1 in lb.) <br />External Short -Circuit Protection <br />10A 250V fuse conforming to IEC60269-1 <br />Applicable Wire Size <br />Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG <br />Contact Resistance <br />Initial contact resistance of 50mQ or less <br />Contact Gap <br />4mm (NO and NC), 2mm (NO-EM and NC -LB) <br />Horsepower Rating <br />Reference Value: 1/4 HP @ 120V (10 non-reversing),1HP @ 240V (3o non -reversing) <br />Electrical Reliability <br />MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) <br />Lamp Ratings <br />Incandescent: 1 W <br />LEDs: 6V/17mA max,12V & 24V/11mA max, 120 & 240V/10mA max <br />Maximum Inrush Current <br />40 A (40 ms) <br />Contact Material <br />Silver (gold plated contacts available - contact IDEC) <br />Contact Block <br />Type HW-C/HW-F/HW-G <br />Pushbuttons <br />Illuminated Pushbuttons <br />600V <br />Rated Insulation Voltage <br />Selector Switches <br />10A <br />Rated Continuous Current <br />Illuminated Selector Switches <br />Contact Ratings by Utilization Category <br />Pushbutton Selectors <br />AC-15 (A600) <br />- <br />IEC 60947-5-1 <br />DC-13(P600) <br />Operational Voltage <br />24V <br />48V <br />50V <br />110V <br />220V <br />440V <br />AC <br />AC-12 Control of resistive loads & solid state loads <br />10A <br />- <br />10A <br />10A <br />6A <br />2A <br />Operational <br />50/60 <br />Hz <br />AC-15 Control of electromagnetic loads (> 72VA) <br />10A <br />- <br />7A <br />5A <br />3A <br />1A <br />Current <br />DC-12 Control of resistive loads & solid state loads <br />8A <br />5A <br />- <br />2.2A <br />1.1A <br />- <br />DC <br />DC-13 Control of electromagnets <br />5A <br />2A <br />- <br />1.1A <br />0.6A <br />- <br />1. For dimensions, see page A3-100. <br />2. For life expectancy Berating curves, seepage A3-105. <br />Tel <br />t <br />www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-53 <br />