LEGEND <br /> SEE SHEET ED FOR LEGEND AND ABBREVIATIONS <br /> SYSTEM SEQUENCE OF OPERATIONS <br /> 1. ALARM CONDITION: <br /> 1.1 ACTIVATION OF ANY ALARM SHALL CAUSE THE FOLLOWING: GENERAL NOTES <br /> a. Alarm indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display ALARM POINT LOCATION INFORMATION. <br /> J. Activate FACP DACT, transmit ALARM signal to Central Station monitoring company. <br /> 2. SUPERVISORY CONDITION: <br /> 2.1ACTIVATION OF ANY SUPERVISORY CONDITION SHALL CAUSE THE FOLLOWING: GENERAL NOTES <br /> a. Supervisory indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display SUPERVISORY POINT LOCATION INFORMATION. <br /> d. Activate FACP DACT, transmit SUPERVISORY signal to Central Station monitoring company. <br /> 3. TROUBLE CONDITION: <br /> 3.1 ACTIVATION OF ANY TROUBLE CONDITION SHALL CAUSE THE FOLLOWING: <br /> a. Trouble indicator LED on FACP to illuminate. <br /> b. FACP Internal Sounder to activate. <br /> c. Display proper message on FACP to display TROUBLE CONDITION. <br /> d. Activate FACP DACT, transmit TROUBLE signal to Central Station monitoring company. <br /> REFERENCE DRAWINGS <br /> FIRE ALARM SEQUENCE OF OPERATIONS <br /> SCALE: NONE E510-5 <br /> ARIES NETLINK POWER SUPPLY AND BATTERY SIZE CALCULATION 4021 BUILDING <br /> TOTAL STAND-BY CURRENT PER SYSTEM: 0.410 AMPS <br /> TOTAL ALARM CURRENT PER SYSTEM: 0.586 AMPS <br /> ENTER STAND-BY HOURS: 48 HOURS <br /> ENTER ALARM TIME: 10 MINUTES <br /> AMPERE HOUR REQUIRED: 19.79 AH <br /> TOTAL AMP HOUR REQUIRE (DERATING FACTOR 1.2): 24.00 AH <br /> BATTERY SIZE REQUIRED PER SYSTEM (TWO(2) BATTERIES REQUIRED): 24 AH <br /> 2-TIERED MAIN OR EXPANSION ENCLOSURE, MAX. 20 AMPS* 15 AMPS <br /> EXPANSION ENCLOSURE(S) REQUIRED? YES <br /> NUMBER OF ENCLOSURE (MAIN / EXPANSION) REQUIRED: 1 Part# Item Description Unit Qty. <br /> NUMBER OF POWER MANAGEMENT UNIT (PMU) BOARD REQUIRED: 1 70-407018-001 AI MODULE N/O-W/O SILICONE lea 1115 <br /> NUMBER OF POWER SUPPLY UNIT (PSU) REQUIRED: 1 <br /> FIRE ALARM BILL OF MATERIALS � <br /> TOTAL TOTAL SCALE: NONE E51`0-5 <br /> ITEM STANDBY STANDBY ALARM ALARM <br /> NO DESCRIPTION QTY (AMPS) (AMPS) (AMPS) (AMPS) <br /> 1 MCB (WITH KEYBOARD/DISPLAY) 1 0.15830 0.15830 0.30000 0.30000 <br /> 2 DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT) EXPANSION CARD 1 0.02400 0.02400 0.03700 0.03700 <br /> 3 REMOTE DISPLAY CONTROL MODULE (RDCM) 1 .090000 0.09000 0.09100 0.09100 <br /> 4 SMARTONE PHOTOELECTRIC SMOKE DETECTOR DS-PS 1 0.00015 0.00105 0.00022 0.00022 <br /> 5 SMARTONE CONTACT INPUT MODULE (AI'S, N/O) 118 0.00058 0.06844 0.00058 0.06844 <br /> 6 POWER MANAGEMENT UNIT (PMU) BOARD #1, MAX. 10.8 AMPS 1 0.07000 0.07000 0.09000 0.09000 / <br /> TOTALS <br /> FIRE ALARM BATTERY CALCULATIONS <br /> SCALE: NONE E510-5 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEA SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY J. SHELDON 08 10 23 FIRE ALARM SYSTEM INFORMATION A 08/10/23 <br /> A SHOP DRAWINGS 40-21/22 VESDA EXPANSION 30748475 FASDESIGN AGOW/PL 08/10/23THIS DESIGN AND/OR CHECKED <br /> m <br /> SP <br /> ECiFlCATION IS APPROVED P. LINAMEN 08 10 23 SHEET SEQUENCE Na. <br /> BOE//VG APPROVED BY DEPT. DATE <br /> " TITLE EVERETT FIRE ALARM SYSTEM TI E510-5 <br /> CHECKED <br /> ete L �ame� APPROVED BUILDING 40-021/22 <br /> "'p' APPROVED EVERETT, WA. DWO"0 40-021-E510-5 <br />