My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10110 19TH AVE SE I-104 2025-08-04
>
Address Records
>
19TH AVE SE
>
10110
>
10110 19TH AVE SE I-104 2025-08-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2023 8:37:32 AM
Creation date
10/23/2023 1:32:55 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10110
Unit
I-104
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1110 <br /> • • • NOTES. <br /> (N)ii"GYPSUM BOARD ,- — <br /> ' ' (E)WALL CONSTRUCTION- <br /> TO REMAIN <br /> 1 _ <br /> UL L502/L514 1 HR PARTITION UL U303 1 HR PARTITION (N)WOOD TRIM — <br /> FLOOR CEILING ASSEMBLY EXTERIOR PARTITIONS: WOOD STUD(LOAD-BEARING) (MATCH EXISTING) \ (E)EXTERIOR FINISH <br /> FIRE RATING: 1 HOUR FIRE RATING: 1 HOUR it — TO REMAIN <br /> STC: 38 STC: N/A <br /> SOUND TEST: CK-6412-7 SOUND TEST' N/A _ <br /> SYSTEM THICKNESS: 11 3 SYSTEM THICKNESS: 5-3/32" <br /> 8," <br /> ASSEMBLY OPTIONS: (N)SEALANT <br /> SYSTEM DESCRIPTION: CEMENT BOARD: 1/2 IN.THICK CEMENT BOARD APPLIED HORIZONTALLY OR <br /> FLOOR SHEATHING. 1 1/4 IN.NOMINAL WOOD FLOOR. VERTICALLY. (E)WINDOW <br /> FLOOR STRUCTURE: 2x10 JOISTS 16 IN.O.C. SHEATHING MATERIALS: 5/8IN.THICK GYPSUM BOARD APPLIED HORIZONTALLY OR <br /> RESILIENT CHANNELS: RC-1,1/2"METAL CHANNELS @ 24"O.C. VERTICALLY. <br /> INSULATION: MIN.3 IN.THICK MINERAL WOOL(R30) WOOD STUDS: 2 IN.X 4 IN.WOOD STUDS SPACED MAX.16 IN.O.C. <br /> CEILING: 5/8 IN.THICK TYPE'X'GYPSUM INSULATION: MIN.3 IN.THICK MINERAL WOOL(R19). <br /> BOARD,JOINT FINISHED. GYPSUM BOARD: 5/8 IN.THICK GYPSUM BOARD APPLIED HORIZONTALLY OR <br /> NOTE VERTICALLY. <br /> NOTE <br /> WHERE NOTED ON PLANS.REPLACE WHERE NOTED ON PLANS,REPLACE <br /> GYPSUM BOARD AND INSULATION TO GYPSUM BOARD AND INSULATION TO <br /> MAINTAIN/COMPLY WITH UL RATINGS AS MAINTAIN/COMPLY WITH UL RATINGS AS /, <br /> SHOWN SHOWN /I NC. REVISED FOR. DATE IY-M-D) <br /> (E)WINDOW—. /IV <br /> 0 CEILING ASSEMBLY O EXTERIOR WALL ASSEMBLY 2_ <br /> 1 SCALE:N.T.S. 2 SCALE N.T.S. 3- <br /> (N)SEALANT �VI,I, eJ <br /> 5. <br /> • (N)WOOD TRIM -=_T� 6_ <br /> WALL CONSTRUCTIONTOREMAIN <br /> -AI1 -(E)EXTERIOR FINISH (MATCH EXISTING) <br /> (E)WALL CONSTRUCTION 7. <br /> (N)SEALANT - - <br /> 1 <br /> (N)g'GYPSUM BOARD - ��I TO REMAIN (E)WOOD — <br /> (N)8"GYPSUM BOARD / STOOL BELOW (N)WOOD SILL(MATCH EXISTING)TRIM— \ ��] R I M K U S <br /> �, (E)WALL CONSTRUCTION J/ -Ali 16932 WOODINVILLE REDMOND ROAD NE A105 <br /> TO REMAIN WOODINVILLE,WA 95072 <br /> (N)WOOD TRIM .11 = (N)8"GYPSUM BOARD EXPERT@RIMKUS.COM <br /> (MATCH EXISTING) � ��_ (800)580-3228 I(86) ' <br /> SEAL1 . , \ <br /> . agCLI$00 <br /> • <br /> 4 0C� $4- <br /> pil _ __ . . i • z <br /> (N)SEALANT / (E)EXTERIOR FINISH— (E)WINDOW (E)EXTERIOR FINISH 4(E)DOOR- / TO REMAIN _A70,443,�� <br /> TYPICAL VO. ISSUED FOR DATE(Y-M-D) <br /> WINDOW JAMB DETAIL <br /> TYPICAL TYPICAL 2. <br /> O WINDOW DOOR DETAIL O WINDOW JAMB DETAIL . 3- <br /> 3 SCALE 3,1,0- 4 SCALE:3,1'-0- 4. <br /> 4. <br /> 5. <br /> 6. <br /> 7. <br /> PROJECT <br /> ARCHITECTURAL REPAIR FOR <br /> FAMIY TREE APARTMENTS <br /> 10110 19TH AVE SE#R200 <br /> EVERETT,WA 98208 <br /> CLIENT <br /> FIRST ONSITE <br /> 21522 84TH AVE SOUTH <br /> SANTA BARBARA,CA 93110 <br /> SHEET TITLE. <br /> SCHEDULES AND <br /> DETAILS <br /> FOR CLIENTS SOLE USE PER GOVERNING CONTRACT <br /> AND LIMITED TO APPLICABLE PROJECT.NO <br /> MODIFICATIONS OR REPRODUCTIONS WITHOUT <br /> WRITTEN APPROVAL OF RIMKUS.CONTRACTOR SOLELY <br /> RESPONSIBLE FOR VERIFYING ALL DIMENSIONS. <br /> PROJECT NO 100206994 <br /> DATE IY-M-D): 2023-03-30 <br /> SCALE AS NOTED <br /> DESIGNED BY RIMKUS <br /> DRAWN BY DJH <br /> CHECKED B" CP <br /> DRAWING NO A501 <br /> SHEET NO <br />
The URL can be used to link to this page
Your browser does not support the video tag.