My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2325 VIRGINIA AVE 2023-10-31
>
Address Records
>
VIRGINIA AVE
>
2325
>
2325 VIRGINIA AVE 2023-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2023 11:23:09 AM
Creation date
10/23/2023 1:54:32 PM
Metadata
Fields
Template:
Address Document
Street Name
VIRGINIA AVE
Street Number
2325
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TIM❑THY NEISER RESIDENCE VICINITY MAP <br /> N <br /> 2325 VIRGINIA AVENUE _ - �_ UM10 <br /> EVERETT, WA 98201 - z-f - ° LUMI❑ HX INC <br /> SOLAR PANEL <br /> SYSTEMS IN TEXAS <br /> PROJECT DESCRIPTI❑N <br /> i— <br /> INSTALL 3,600kW DC GRID TIED, ROOF FLUSH, MOUNTED PV SYSTEM, TIE INT❑ EXISTING 2000 E LAMAR BLVD_ J <br /> 200/200A MAIN SERVICE PANEL SUITE 300 <br /> ARLINGT❑N, TX 76006 <br /> SYSTEM SPECIFICATIONS ' <br /> � =. -�;� ' 3— 1 (888) 515-6199 <br /> AHJ: CITY OF EVERETTLOCATION <br /> _ a <br /> UTILITY COMPANY: SN❑PUD <br /> SYSTEM SIZE; 3.600kW DC - ; 16 <br /> _ 1 <br /> 2.700kW AC <br /> ;; <br /> SOLAR MODULES MAKE: Q,ANTUM DUO Z i E, 'd• U IDo 0 <br /> MODEL: Q.PEAK DUO BLK ML—G10+ 4001 .r • �. _ �t H m M o <br /> QUANTITY: 9 _— i U U > co ni O <br /> f _ <br /> MICR❑INVERTERS MAKE; ENPHASE U z 3 v o <br /> Q o <br /> MODEL: IQ8PLUS-72-2-US "� ' .l w _ _ H 00 0 0 <br /> 1 <br /> QUANTITY: 9 64 °• j0� r-- <br /> U-)~ W > wW <br /> cu+- Nw0_ w ¢ <br /> JL LD � o <br /> t <br /> GENERAL NOTES: SHEET INDEX <br /> 1. SOLAR PV SYSTEM TO BE INSTALLED ON EXISTING RESIDENTIAL STRUCTURE, <br /> 2. ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATI❑NAL BUILDING CODE, THE TS001 TITLE SHEET DRAWN BY <br /> DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES, NICHOLAS RICKE <br /> 3. CONTRACTORS SHALL OBTAIN FIRE CERTIFICATION UPON COMPLETION OF WORK, <br /> 4. THE STRUCTURE IS 1 STORY(IES) TALL, B001 SITE PLAN DRAWING DATE <br /> 5. THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM. <br /> 6. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS, 10/27/2022 <br /> 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTI❑N POINTS IDENTIFIED ON THE MODULE AND MANUFACTURE'S INSTALL INSTRUCTI❑NS. B002 ROOF PLAN REVISIONS <br /> 8. A LADDER SHALL BE PLACED FOR INSPECTION PER OSHA REGULATIONS, CHANGES DATE <br /> 9. PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED AS PER SECTI❑N 110.26 NEC, <br /> 10. ALL PV MODULES SHALL BE TESTED AND CERTIFIED BY A RECOGNIZED TESTING LABORATORY ACCREDITED BY UNITED STATES OSHA. E001 CONNECTION DETAIL <br /> 11, ALL SIGNAGE SHALL BE PLACED IN ACCORDANCE WITH NATI❑NAL ELECTRIC CODE AND ALL LOCAL ORDINANCES AND BE OF SUFFICIENT DURABILITY TO <br /> WITHSTAND ENVIRONMENTAL FACTORS. <br /> E002 MOUNTING DETAIL <br /> ELECTRICAL NOTES: E003 ❑NELINE <br /> 1. THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED BY A QUALIFIED PERSON, <br /> 2. THE SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE LOCAL JURISDICTI❑N AND THE UTILITY COMPANY. FOR A LINE SIDE TAP <br /> INTERCONNECTI❑N THE UTILITY SHALL BE NOTIFIED IN ADVANCED TO C❑ORDINATE BUILDING ELECTRICAL SHUTOFF, E004 ELECTRICAL CALCS <br /> 3. NEW CONDUIT RUNS ARE SUGGESTI❑NS, CONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS. <br /> 4. BACKFEED BREAKER SHALL BE LOCATED AT THE OPP❑SITE END OF THE BUSBAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE <br /> UTILITIES, S002 LABELS <br /> 5. ALL CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE UV RESISTANT <br /> 6. CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 AND IFC 605.11. <br /> 7. PV OUTPUT CONDUCTORS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTI❑N AND SPLICES, IDENTIFICATI❑N SHALL COMPLY WITH NEC 690.4 <br /> 8. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A G001 BILL OF MATERIALS <br /> SUPPLEMENTAL GROUNDING ELECTRODE, <br /> WIRING AND CONDUIT NOTES: MSD DATA SHEETS <br /> 1. ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATI❑NS Governing Codes <br /> 2. ALL CONDUCTORS AND ❑CPD SHALL BE SIZED IN ACCORDANCE WITH NEC 690.8(A)(1), NEC 690.8(B)(1), NEC 240 AND NEC 690.7 SHEET TITLE SHEET NUMBER <br /> 3. VOLTAGE DROP LIMITED TO 2% Electrical Code NEC 2020&Washington Administrative Code&WCEC 2020 <br /> Fire Code IFC 2018 TITLE <br /> Building Code IBC 2018 SHEET TS001 <br /> Residential Code IRC 2018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.