O CONDUCTOR AND CONDUIT SCHEDULE SYSTEM SIZE: EQUIPMENT SCHEDULE _
<br /> LINE CONDUCTOR TYPE CONDUCTOR NUMBER OF CONDUIT CONDUIT SIZE DC: 3,600 Kw I (9)Q,ANTUM DUO Z Q,PEAK DUO BLK ML-G10+ 400 iumlo
<br /> SIZE (AWG) CONDUCTORS TYPE AC: 2,700 Kw
<br /> L1, L2 Q CABLE 12 2 N/A N/A 2 (9)ENPHASE IQ8PLUS-72-2-US WIRED IN SERIES IN (1) BRANCH,
<br /> 1 G BARE COPPER EGC 6 1 N/A N/A 3 NEMA 3R RATED JUNCTI❑N B❑X, VISIBLE AND ACCESSIBLE L U MI❑ H X INC
<br /> L1, L2 THHN 12 2 EMT 3/4' 4 (1) NEW ENPHASE COMBINER 4 X-IQ-AM1-240-4 WITH FACTORY INSTALLED ENVOY AND DUAL SOLAR PANEL
<br /> 2 G THHN EGC 6 1 EMT 3/4' POLE BREAKER(S), SEE DIAGRAM FOR RATINGS, SYSTEMS IN TEXAS
<br /> (1) NEW Eaton DG221URB RATED AT 30 A, NEMA 3R, JACK KNIFE DISCONNECT, VISIBLE,
<br /> L1, L2, N THHN 6 3 EMT 3/4' S LOCKABLE, AND ACCESSIBLE, <10FT FROM METER
<br /> 3 G THHN EGC 6 1 EMT 3/4' 2000 E LAMAR BLVD
<br /> 6 (1) EXISTING CUTLER-HAMMER SINGLE PHASE 200/200 MAIN DISTRIBUTI❑N PANEL, LOCATE A SUITE 300
<br /> 15A BACKFEED BREAKER ON THE ❑PP❑SITE SIDE OF THE BUS FROM THE MAIN DISCONNECT ARLINGT❑N, TX 76006
<br /> 7 (1) BI-DIRECTI❑NAL UTILITY METER #00401649801300, 120V/240V
<br /> 1 (888) 515-6199
<br /> NOTES
<br /> LOCATION
<br /> 1. ROOFTOP CONDUIT SHALL BE INSTALLED NO LESS THAN 7/8' ABOVE THE ROOF DECK,
<br /> 2. GROUNDING SHALL BE IRREVERSIBLE CRIMPED,
<br /> 3. IF UFER IS NOT PRESENT, 2 GROUNDING RODS ARE REQUIRED TO BE INSTALLED 6 FEET
<br /> APART, BONDED TOGETHER WITH #6 AWG, COLD WATER LINE AND GAS LINE NEED TO BE
<br /> BONDED PER NEC 250.53
<br /> 4. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, TESTED, OR CERTIFIED BY A NATI❑NAL
<br /> RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES ❑CCUPATI❑NAL
<br /> SAFETY HEALTH ADMINISTRATI❑N, W ID0 0
<br /> 5 .WHEN A BACKFEED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER (� m M CD
<br /> SHALL NOT READ 'LINE' OR 'LOAD', I--I W w N M o
<br /> �
<br /> 6 .CONDUIT SHALL NOT PASS WITHIN 10 FEET OVERHEAD OF THE GAS RISER. W U > co ai CD m
<br /> 7, ALL EMT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS PER NEC 314.15. z ¢ Mv
<br /> 8, CONDUIT ON THE ROOF SHALL BE RAN TO REDUCE TRIP HAZARDS AND MAXIMIZE z LLJ ¢ ¢ I `0 0
<br /> VENTILATION ❑PP❑RTUNITIES BY F❑LL❑WING RIDGES, HIPS, AND VALLEYS, CONDUIT RUNSz 3 v
<br /> FROM COMBINER BOXES OR THE LAST ARRAY SHALL FOLLOW, AS CLOSE AS POSSIBLE, THEQ 0 0
<br /> RIDGE, HIP OR VALLEY TO THE NEAREST OUTSIDE WALL. V) - w °D
<br /> 9. CONDUIT RUNS BETWEEN ARRAYS AND/DR COMBINER BOXES SHALL BE RUN SUCH THAT > � r #
<br /> CONDUIT PATHS ARE MINIMIZED AND STILL COMPLY WITH THE ROUTING NOTED ABOVE, ~ W u� w w
<br /> 10. DC WIRING WHEN RAN IN THE ATTIC OR ENCLOSED SPACES SHALL BE IN CONDUIT AND, TO �/ cu w ri,
<br /> THE MAXIMUM EXTENT POSSIBLE, BE RAN ALONG THE BOTTOM OF LOAD BEARING MEMBERS, N 0_ Ld <
<br /> 11. RACEWAY SHALL BE PROVIDED WITH EXPANSI❑N, EXPANSI❑N-DEFLECTI❑N, OR DEFLECTI❑N I--I
<br /> FITTING WHERE NECESSARY TO COMPENSATE FOR THERMAL EXPANSI❑N, DEFLECTI❑N AND
<br /> C❑NTRACTI❑N.
<br /> 10FT FROM METER
<br /> DRAWN BY
<br /> NICH❑LAS RICKE
<br /> 6 7 DRAWING DATE
<br /> 10/27/2022
<br /> 4 REVISIONS
<br /> CHANGES DATE
<br /> EXISTING
<br /> 200/200
<br /> ENVY
<br /> 200A
<br /> LUG
<br /> 3 15A 5
<br /> 1 9 O 00 2 1
<br /> 2 ti O 00 ti 15A g15A
<br /> I I I
<br /> SHEET TITLE SHEET NUMBER
<br /> 1 2 3 3
<br /> VISIBLE LOCKABLE LABELED DISCONNECT
<br /> LOCATED WITHIN 1OFT OF UTILITY METER. ❑NELINE E001
<br />
|