My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2325 VIRGINIA AVE 2023-10-31
>
Address Records
>
VIRGINIA AVE
>
2325
>
2325 VIRGINIA AVE 2023-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2023 11:23:09 AM
Creation date
10/23/2023 1:54:32 PM
Metadata
Fields
Template:
Address Document
Street Name
VIRGINIA AVE
Street Number
2325
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EN PHASE. IQ8 Series Microinverters <br /> INPUT DATA IDCJ1: .1 1: 1: 1: 1: 1 1: 1: <br /> Commonly used module pairingsz W 235-350 235-440 260-460 295-500 320-540- 295-500- <br /> Module <br /> 95-500+Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell <br /> MPPT voltage range V 27-37 29-45 33-45 36-45 38-45 38-45 <br /> Operating range V 25-48 25-58 <br /> Min/max start voltage V 30/48 30/58 <br /> Max input DC voltage V 50 60 <br /> Max DC current3[module Ise] A 15 <br /> Overvoltage class DC port II <br /> _ DC port backfeed current mA 0 <br /> PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit <br /> OUTPUT DATA (ACI IQ8-60-2-US IQ8PLUS-72-2-US 108M-72-2-US 108A-72-2-US 108H-240-72-2-US IQSH-208-72-2-US <br /> i <br /> Peak output power VA 245 300 330 366 384 366 <br /> Max continuous output power VA 240 290 325 349 380 360 <br /> Nominal(L-L)voltage/range4 V 240/211-264 208/183-250 <br /> Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 <br /> Nominal frequency Hz 60 <br /> IQ8 Series MIcroinverters Extended frequency range Hz 50-68 <br /> Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Max units per 20 A(L-L)branch circuits 16 13 11 11 10 9 <br /> defined microinverters with split-phase power conversion capability to convert DC Total harmonic distortion <5% <br /> power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install Overvoltage class AC port III <br /> is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with <br /> AC port backfeed current mA 30 <br /> microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors <br /> 55nm technology with high speed digital logic and has super-fast response times Power factor setting 1.0 <br /> • Power Line Communication <br /> to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging <br /> energy systems. Faster installation with simple Peak efficiency % 97.5 97.6 97.6 97.6 97.6 97.4 <br /> • <br /> two-wire cabling CEC weighted efficiency % 97 97 97 97.5 97 97 <br /> Enphase Night-time power consumption mW 60 <br /> e"^•' High productivity and reliability MECHANICAL DATA <br /> • Produce power even when the Ambient temperature range -40°C to+60°C(-40°F to+140°F) <br /> year limited grid is down Relative humidity range 4%to 100%(condensing) <br /> warranty <br /> t I — • More than one million cumulative DC Connector type MC4 <br /> Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefine reliability hours of testing <br /> Microinverters integrate with the Enphase IQ standards with more than one million Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") <br /> Battery,Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing, Class II double-insulated Weight 1.08 kg(2.38 lbs) <br /> App monitoring and analysis software. enabling an industry-leading limited warranty enclosure <br /> of up to 25 years. Cooling Natural convection-no fans <br /> • Optimized for the latest high- <br /> powered PV modules Approved for wet locations Yes <br /> Acoustic noise at 1 m <60 dBA <br /> Microgrid-forming Pollution degree PD3 <br /> CERTIFIEDep=:r Complies with the latest Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> advanced grid support Environ.category/UV exposure rating NEMA Type 6/outdoor <br /> Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for 1 <br /> IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 <br /> Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed <br /> connectors. according to manufacturer's instructions. Configurable to support a wide <br /> 9 PP Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section <br /> range of grid profiles 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to <br /> manufacturer's instructions. <br /> ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 microinverters, Meets CA Rule 21(UL 1741-SA) <br /> and other names are trademarks of Enphase Energy,Inc.Data subject to change. requirements (1)The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC.(2)No enforced DC/AC ratio.See <br /> the compatibility calculator at https://Iink.enphase.com/module-compatibility(3)Maximum continuous input <br /> IQ8SE-DS-0001-01-EN-US-2022-03-01 DC current is 10.6A(4)Nominal voltage range can be extended beyond nominal if required by the utility.(5) <br /> Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SE-DS-0001-01-EN-US-2022-03-01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.