Laserfiche WebLink
DESIGN SPECIFICATION MODULE TYPE, DIMENSIONS&WEIGHT ROOF DESCRIPTION ARRAY AREA&ROOF AREA CALC'S <br /> RISK CATEGORY: II NUMBER OF MODULES: 24 MODULES ROOF ROOF AZIMUTH TRUSS TRUSS ROOF MATERIAL ROOF #OF MODULES ARRAY AREA(Sq. Ft.) Lumio <br /> CONSTRUCTION: SFD MODULE TYPE: Q CELLS Q.PEAK DUO BLK TILT SIZE SPACING #1 3 63.37 <br /> ML-G10+ (400W) #1 27° 180° 2"x 4" 24"o.c. COMP SHINGLE SMART ENSEE GYTODAY <br /> ZONING: RESIDENTIAL #2 8 168.97 (SET) <br /> MODULE WEIGHT: 48.5 LBS #2 27° 270° 2"x 4" 24"o.c. COMP SHINGLE 1550 DIGITAL DR,LEHI,UT <br /> SNOW LOAD (ASCE7-16): 25 PSF #3 3 63.37 84043,USA <br /> EXPOSURE CATEGORY: 1C MODULE DIMENSIONS: 74"X 41.1" =21.12 SF #3 27° 180° 2"x 4" 24"o.c. COMP SHINGLE #4 1 6 126.73 <br /> WIND SPEED (ASCE7-16): 111OMPH UNIT WEIGHT OF AREA: 12.3 PSF #4 27° 90° 2"x 4" 24"o.c. COMP SHINGLE #5 1 4 84.49 <br /> #5 27° 90° 2"x 4" 24"o.c. COMP SHINGLE (TOTAL ARRAY AREA/TOTAL ROOF AREA)X 100% <br /> LEGEND <br /> JB I (N)JUNCTION Box = (506.9/2650.5)X 100%= 19.13% <br /> 71 UM O BLK ML-G10+ <br /> Q.PEAK D <br /> (E)UTILaITY METER S24 Q CELLS <br /> MSP (E) MAIN SERVICE PANEL K U <br /> (400W) <br /> (24)ENPHASE <br /> IQ (N)ENPHASE IQ COMBINER <br /> IQ8PLUS-72-2-US(240V) <br /> R <br /> (E) BACK OF RE5IDENCE <br /> AC DC SYSTEM SIZE:9.600 kWDC <br /> (N)FUSED AC DISCONNECT <br /> 1-14-31 AC SYSTEM SIZE:7.200 kWAC <br /> n <br /> VENT,ATTIC FAN(ROOF <br /> OBSTRUCTION) p i n <br /> ROOF ATTACHMENT S -7�i <br /> CONDUIT <br /> ❑ ENPHASE IQ8PLUS-72-2-US(240V) REVISIONS <br /> MICROINVERTER DESCRIPTION DATE REV <br /> to <br /> r' <br /> _ �f �` A _ <br /> Q CELLS Q.PEAK DUO BLK �_ 1 <br /> ML-G10+(400W)MODULES 'Q� S� 10'-811 <br /> 0'-8" 109-41' 11'-9" <br /> UNIRAC SOLARMOUNT LIGHT 9C „ A ,� PROJECT NAME&ADDRESS <br /> RAIL 168"MILL �C <br /> TRENCH • /J� FI011 <br /> ROOF#3 <br /> PANEL HEIGHT OFF ROOF 6" l`7 ,t� • rn' TILT-27` U) <br /> DEAD LOAD CALCULATION • ■ , D AZIM. 180° <br /> EQUIPMENT'S QTY LBS/UNI TOTAL WEIGHT ROOF#2 • s • SF���Fj�� • •_ • m` � H 0 <br /> DESCRIPTIONS TILT-27° C' <br /> AZIM -270° N /�-' ,C',,�, Z rn O <br /> MODULES 24 48.5 1164 O • • � 1 C LQ N <br /> / N <br /> • K <br /> MID CLAMP 32 0.3 9.6 OD � ` ■ - IY 00 <br /> END CLAMP 32 0.31 9.92 • -� • • J U O <br /> UNIRAC SOLARMOUNT 15 6.89 103.35 _ / . ■ m o <br /> LIGHT RAIL 168" MILL C ovtiv� ` ' 'j7y/A , • • • ROOF#5 W � 2 <br /> SPLICE BAR 2 0.65 1.3 • • _ O AZIM. 90° Ill w W o <br /> RT-200-MINI BK2 59 0.5 29.50 I Z o <br /> TOTAL WEIGHT OF THE SYSTEM (LBS) 1317.67 • • a • a • J - U) Z <br /> TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 506.9 p ` SET FA K / • � 0- Q <br /> 36" FIRE _ _ <br /> WEIGHT PER SQ. FT. (LBS) 2.6 — TBACK ' U <br /> A <br /> WEIGHT PER PENETRATION (LBS) 22.34 <br /> f 11'-0" �� r * -�• OD <br /> N <br /> Cfl y - DATE: 10/28/2022 <br /> ROOF#4 10'-r, / 10#-411 <br /> TILT-27° SHEET NAME <br /> AZIM. -90° ROOF#1 ROOF PLAN <br /> TILT-27° <br /> (E) FRONT OF RE5IDENCE AZIM -180° <br /> SHEET SIZE <br /> 79TH PL 5W ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> SCALE: 1/8"= 1'-0" PV-3 <br />