Laserfiche WebLink
ID TYPICAL INITIAL CONDUCTOR FINAL CONDUCTOR CONDUCTOR CONDUIT #OF CURRENT-CARRYING CONDUIT OCPD EGC TEMP.CORR. CONDUIT CONT. MAX. BASE DERATED TERM. LENGTH VOTAGE <br /> LOCATION LOCATION PARALLEL CONDUCTORS IN FILL FACTOR FILL CURRENT CURRENT AMP. AMP. TEMP. DROP <br /> CIRCUITS CIRCUIT PERCENT FACTOR RATING Lumio <br /> 1 2 ARRAY JUNCTION BOX 12 AWG Q CABLE COPPER - 1 2 N/A N/A 6 AWG BARE 0.82 (48°C) N/A 14.52A 18.15A N/A N/A 75°C 74FT -7-65-- <br /> COPPER <br /> SMART ENERGY TODAY <br /> 2 1 JUNCTION BOX IQ COMBINER BOX 12 AWG THWN 2 COPPER MIN 0.75'DIA 2 4 16.70% 20A 6 AWG THWN-2 1 (26°C) 0.8 14.52A 18.15A 30A 24.00A 75°C 38FT 0.94% (SET) <br /> EMT COPPER 1550 DIGITAL DR,LEHI,UT <br /> 3 1 IQ COMBINER BOX FUSED AC 6 AWG THWN 2 COPPER MIN 0.75'DIA 1 3 36.77% 40A 6 AWG THWN-2 1 (26°C) 1 29.04A 36.3A 75A 75.00A 75°C 5FT 0.06% 84043,USA <br /> DISCONNECT EMT COPPER <br /> 4 1 FUSED AC MSP 6 AWG THWN 2 COPPER MIN 0.75"DIA 1 3 36.77% N/A 6 AWG THWN-2 1 (26°C) 1 29.04A 36.3A 75A 75.00A 75°C 5FT 0.06% <br /> DISCONNECT SCH 40 PVC COPPER <br /> SNO. EQUIPMENTS MAX CURRENT OCPD <br /> IQ COMBINER NO.OF MICROINVERTERS IN A STRING X OUTPUT SYSTEM INFO <br /> 1 BOX CURRENT OF MICROINVERTERS X 1.25=MAX 12X1.21X1.25=18.2A 20A (24)Q CELLS <br /> CURRENT Q.PEAK DUO BLK ML-G10+ <br /> TOTAL NO.OF MICROINVERTERS X OUTPUT ( <br /> 2 FUSED AC CURRENT OF MICROINVERTER X 1.25=MAX 24X1.21X1.25=36.3A 40A ( NPH <br /> IQBPLUS EENPH ASE <br /> -72-2-US(240V) <br /> DISCONNECT CURRENT <br /> TO UTILITY GRID DC SYSTEM SIZE:9.600 kWDC <br /> AC SYSTEM SIZE:7.200 kWAC <br /> 1 <br /> BI-DIRECTIONAL UTILITY <br /> BRANCH 1 <br /> 1-PH,3-W, 120V/240V REVISIONS <br /> 12- Q CELL Q.PEAK DUO BLK ML-G10+ (400W) MODULES POINT OF <br /> INTERCONNECTION DESCRIPTION DATE REV <br /> LINE SIDE TAP 1 2 rd 1 <br /> /T (E)MAIN BREAKER TO <br /> • • • HOUSE 240 V.20OA/2P <br /> PRODUCTION CT'S <br /> � KNIFE SWITCH �� �' PROJECT NAME&ADDRESS <br /> 0CABLE JUNCTION BOX AC DISCONNECT: <br /> 600 V, NEMA 3R, 2 GATEWAY 240V, 60A FUSED PA MAIN SERVICE <br /> �, �, �, q °°°"°� j=°''- NEMA 3R, UL LISTED `1 " PANEL.200A RATED, <br /> UL LISTED __� 1-PH.3-W,240V a <br /> (2)40A FUSES U) <br /> �- <br /> 20 2P 15A/2P y L2— i_ L1-' __L1 Z) <br /> 1 u <br /> ( A _ N N L M <br /> - N o <br /> BRANCH 2 r 2UA/2P' ° ° / 00 <br /> 12- Q CELL Q.PEAK DUO BLK ML-G10+ (400W) MODULES ���� r "i 'i w m o <br /> 4 (� N <br /> I� U o) <br /> • r i m Z W oM <br /> (N)ENPHASE IQ LU IY m <br /> COMBINER 4C BOX WIRELESS COM KIT EXISTING GROUND � o <br /> (X-I0-AM1-240-4C) ELECTRODE CONDUCTOR W W W O <br /> ti ti U U) Z <br /> 0- d <br /> _ T_ a <br /> V F- <br /> 0') <br /> (24)ENPHASE I08PLUS-72-2-US(240V)MICROINVERTERS Lo <br /> N <br /> DATE: 10/28/2022 <br /> SHEET NAME <br /> SERVICE INFO ELECTRICAL <br /> UTILITY PROVIDER: SNOPUD LINE & CALCS. <br /> AHJ NAME: EVERETT CITY <br /> MAIN SERVICE VOLTAGE: 240V SHEET SIZE <br /> MAIN PANEL BRAND: GE ANSI B <br /> MAIN SERVICE PANEL: 200A 11" X 17" <br /> MAIN BREAKER RATING: 200 A <br /> MAIN SERVICE LOCATION: WEST SHEET NUMBER <br /> SERVICE FEED SOURCE: UNDERGROUND PV-7 <br /> SCALE: NTS <br />