Laserfiche WebLink
A B C D E F G I H <br /> CONDUCTOR SCHEDULE <br /> COMBINER BOX PANEL SIZE CALCS CONDUCTORS GROUND <br /> NUMBER OF NUMBER OF NOMINAL OUTPUT COMBINED CURRENT FOR HM-1200,600 300 <br /> TOTAL 125% TOTAL BREAKER SIZE INVERTER NUMBER OF NOMINAL OUTPU COMBINED <br /> CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL TOTAL WIRES IN MINIMUM MINIMUM <br /> CIRCUIT 1 1 of 2 1 1 X 1.23A = 1.23A 1.25 = 1.54A CONDUIT WIRE SIZE TYPE, SIZETYPE INVERTERS CURRENT TOTAL TAG ID TYPE,MATERIAL TYPE,MATERIAL <br /> CIRCUIT 1 2 of 21 10 5X 2.46A = 12.30A X 1.25 = 15.38A 16.91A = 20A HM-1200 0 x 5.OA <br /> HM-600 9 X 2.46A = 22.14A = 23.37A A' 6 #12 AWG PV CABLE,CU #6 AWG BARE,CU <br /> CIRCUIT 2 8 4 X 2.46A - 9.84A X 1.25 - 12.30A = 12.30A - 20A HM-300 1 X 1.23A = 1.23A <br /> B 5 #12 AWG THWN-2,CU #B AWG THWN-2,CU � <br /> C 3 #8AWG THWN-2,CU #8AWG THWN-2,CU <br /> LOAD CALCS-TOTAL AMPS AVAILABLE D- 4 #8AWG THWN-2,CU #6 AWG THWN-2,Cu <br /> BUS RATING 120% TOTAL MAIN BREAKER MAX BREAKER SIZE BREAKER SIZE CALCS -TAG A CABLE WILL BE RUN THROUGH ATTIC WHERE POSSIBLE "TAG D ONLY IF APPLICABLE' <br /> 200A X 1.2 - 240 200A - 40A MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE <br /> 23.37A x 1.25 x 29.21A - 30A <br /> 1 YINGLI YL365D-34D MODULE 10 YINGLI YL365D-34D MODULES <br /> WITH HOYMILES HM-300 MICRO INVERTER WITH HOYMILES HM-600 MICRO INVERTERS <br /> (1 OF 2) (2 OF 2) <br /> --------- ----- <br /> N N <br /> (J1 (11 . . . (21 (1 <br /> NOTES: <br /> 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) <br /> 2. 200A LOAD CENTER.(EXISTING) <br /> 3. 30A RATED NON-FUSED LOCKABLE AC DISCONNECT. <br /> (NEW) <br /> _ — = 4. 125A RATED COMBINER PANEL.(NEW) <br /> ALL CONDUIT SIZES ARE MINIMUM SIZES <br /> ALL WIRE SIZES ARE FOR COPPER WIRE <br /> I UTILITY <br /> 8 YINGLI YL365D-34D MODULESI SERVICE <br /> WITH HOYMILES HM-600 MICRO INVERItER 120/240V <br /> M SINGLE PHASE w <br /> --------- ----- ---- <br /> 1 <br /> (81 (21 (1) <br /> M <br /> (N)240V/60A PV <br /> 125A LOAD CENTER, 2 <br /> NEMA 3R RATED 200A RATED <br /> q g (N)UTILITY 200A MAIN SERVICE <br /> AC DISCONNECT MAIN <br /> 240V/30A NEMA 3R DISCONNECTPANEL <br /> NON-FUSIBLE, A <br /> VISIBLE-LOCKABLE (E)LOADS <br /> F-I 2 0 A--'b � LABELED <br /> 20A <br /> (N)PV OCPD <br /> 2P-30A <br /> ---------- —� I <br /> ---------- — D — — —� <br /> I I <br /> I I <br /> L ---J <br /> NEMA3R RATED 30A LOAD-SIDE FACILITY GROUND <br /> JUNCTION BOX:SHALL 3 SOLAR OCPD GROUND ROD <br /> LO COMPLY W/NEC 110.3 (Opposite end of the main disconnect cn <br /> &314.6 on the busbar-NEC 705.12(B)(3) <br /> 4 <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED EAC NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Jessica P i scaDESIGN <br /> S <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> DATE: <br /> OL G C N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5715 BEDFORD ST, 28/09/2023 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 3730 Wetmore Ave Everett WA 98201 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV <br /> CONSENT FROM SOLGEN POWER. <br />