My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3730 WETMORE AVE 2023-10-31
>
Address Records
>
WETMORE AVE
>
3730
>
3730 WETMORE AVE 2023-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2023 1:06:50 PM
Creation date
10/24/2023 6:13:23 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3730
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOLGLN <br /> P O W E R <br /> September 30, 2023 <br /> Subject: Proposed Solar Panel Installation <br /> Jessica Pisca Residence, 3730 Wetmore Ave, Everett,WA <br /> To Whom it May Concern, <br /> Our engineering department has reviewed information, gathered by our field crews, related to the proposed solar <br /> panel installation at the above-referenced address. The purpose of our review was to determine the structural <br /> adequacy of the existing roof. Based on our review and analysis of the available information, and in accordance <br /> with governing building codes, it is our professional opinion that the existing structure is permitted to remain <br /> unaltered for the proposed solar installation. <br /> Design Parameter Summary <br /> Governing Building Code: 2018 Washington Building Code (2018 IBC) <br /> Risk Category: II <br /> Design Wind Speed: 110 mph (per ASCE 7-16) <br /> Ground Snow Load: 15 psf <br /> Roof Information <br /> Roof Structure: 2x4 Rafters @ 24" O.C. <br /> Roofing Material:Asphalt Shingles(1 layer) <br /> Roof Slope: 14 degrees& 37 degrees <br /> Roof Connection Details <br /> RT Minis. Install generally into 2x rafters/chords, but up to 50% may be installed into decking only.48" O.C.. Install <br /> Lag Screws: 5/16" diameter min.,with min. 2.5" embedment into framing members, at 48" O.C. max, staggered <br /> Locations per design drawings <br /> Note:Required embedment length excludes the tapered tip of the screw,and embedment into sheathing. <br /> Analysis <br /> The proposed installation complies with the requirements of WAC Section 51-51-03240 R324.4 (Exception) and is <br /> therefore deemed adequate to support the load of the rooftop solar system. <br /> Specifically: 1) the system is designed for the local wind speed; 2) the ground snow load does not exceed 70 psf; 3) <br /> the total dead load of all items is less than 4 psf (actual value is approximately2.65 psf); 4) Modules are not <br /> mounted more than 18" off the roof; and 5) Supports are installed such that the dead load is spread across roof- <br /> framing members and does not exceed 50 lbs at any point. <br />
The URL can be used to link to this page
Your browser does not support the video tag.