i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: M2211-001 Description:AIR HANDLER AND HEAT PUMP INSTALL <br /> Applied: 11/1/2022 Approved: 11/3/2022 Site Address: 3223 OAKES AVE <br /> Issued: 11/4/2022 Finaled: 10/23/2023 City,State Zip Code: EVERETT,WA 98201 <br /> Status: FINALED Applicant:CM AIR PROS LLC(CONST) <br /> Parent Permit: Owner: INCOGNITO JONAYLE O&KATELYN B <br /> Parent Project: Contractor: CM AIR PROS LLC(CONST) <br /> Details: <br /> AIR HANDLER AND HEAT PUMP INSTALL <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 11/21/2022 11/21/2022 MECH 06-FINAL JASON NO ACCESS see notes <br /> MORRISSEY <br /> Notes: <br /> 11/16/2022 10:52 AM Katelyn Incognito <br /> I don"t know what type of inspection I need.This is for a recently installed heat pump. <br /> Contact Name:Katelyn Incognito <br /> Site Address:3223 OAKES AVE <br /> Phone:4254052159 <br /> e-Mail:Ktvlsp3@gmail.com <br /> -No access.No answer at door! <br /> 2/27/2023 2/27/2023 MECH 06-FINAL JEFF M RHODE CORRECTION see notes <br /> REQUIRED <br /> Notes: <br /> 2/20/2023 8:39 AM CM AIR PROS LLC(CONST) <br /> please call on the way <br /> Contact Name:Katie Incognito <br /> Site Address:3223 OAKES AVE <br /> Phone:4254052159 <br /> e-Mail:ktvlsp3@gmail.com <br /> -no auxiliary condensate control. <br /> 814.2 Condensate Control <br /> Where an equipment or appliance is installed in a space where damage is capable of resulting from condensate overflow,other than damage to <br /> replaceable lay-in ceiling tiles,a drain line shall be provided and shall be drained in accordance with Section 814.1.An additional protection method for <br /> condensate overflow shall be provided in accordance with one of the following: <br /> A water level detecting device that will shut off the equipment or appliance in the event the primary drain is blocked. <br /> An additional watertight pan of corrosion-resistant material,with a separate drain line,installed beneath the cooling coil,unit,or the appliance to catch <br /> the overflow condensate due to a clogged primary condensate drain. <br /> An additional drain line at a level that is higher than the primary drain line connection of the drain pan. <br /> An additional watertight pan of corrosion-resistant material with a water level detection device installed beneath the cooling coil,unit,or the appliance <br /> to catch the overflow condensate due to a clogged primary condensate drain and to shut off the equipment. <br /> The additional pan or the additional drain line connection shall be provided with a drain pipe of not less than 3/4 of an inch(20 mm)nominal pipe size, <br /> discharging at a point that is readily observed. <br /> I <br /> Printed:Tuesday,24 October, 2023 1 of 2 rk <br /> SUPERION <br />