9909 2ND AVE W 2018-08-01
>
Address Records
>
2ND AVE W
>
9909
>
9909 2ND AVE W 2018-08-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2018 1:48:11 PM
Creation date
5/31/2016 11:31:19 AM
Metadata
Fields
Template:
Address Document
Street Name
2ND AVE W
Street Number
9909
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
178
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DETENTION VAULT 1 <br /> Dimensions Bottom Area Volume <br /> Sediment Chamber Size-Modeled 56'x 4'x 6' 224 sf 1,344 cf <br /> Detention Chamber Size-Modeled 42'x 24'x 4.5' 1,008 sf 4,536 cf <br /> Detention Chamber Size with 30% 56'x 24'x 4.5' 1,344 sf 6,048 cf <br /> Correction Factor-Designed <br /> The second proposed detention vault(Vault 2) will be located between units 13, 14& 15 under <br /> the proposed driveway. It will have a control structure designed to release peak runoff at pre- <br /> developed runoff rates of 50%of the 2-year and 100%of the 10-year and 100-year storm events. <br /> The control structure will be located outside the vault and be accessible from the proposed <br /> driveway. <br /> Vault 2 is composed of two chambers. Stormwater entering the vault goes into the first chamber <br /> sized to provide sediment treatment for the stormwater. From the first chamber the water exits <br /> the vault and is filtered by two Contech Catchbasin Stormfilters. Stormwater then enters the <br /> second vault chamber from the filter and is detained until it can be released at pre-developed <br /> rates. The storm filter will provide water treatment for Basin 2 and the site frontage only. <br /> The table below summarizes the design for Vault 2. <br /> DETENTION VAULT 2 <br /> Dimensions Bottom Area Volume <br /> Sediment Chamber Size-Modeled 82'x 4'x 4.6' 328 sf 1,509 cf <br /> Detention Chamber Size-Modeled 54'x 24'x 1,296 sf 6,804 cf <br /> 5.25' <br /> Detention Chamber Size with 30% 72'x 24'x 1,688 sf 9,072 cf <br /> Correction Factor- Designed 5.25' <br /> After exiting the vault control structures, stormwater will flow east to level spreaders bordering <br /> the onsite wetland. <br /> Water quality-Water quality treatment will be provided for a 6-month peak flow rate calculated <br /> as 74% of a 2-yr design storm event. Released runoff will flow through a Contech Stormfilter. <br /> The Stormfilter cartridge vault configuration will provide water quality treatment for the runoff <br /> in accordance with DOE requirements and will remove approximately 80% of the pollutants in <br /> the runoff from the drainage area. <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.