Laserfiche WebLink
SORIANO ADDITION <br />October 4, 2021 _,j SDA Job # 9314 1 8 <br />Floor Info' <br />ROOF I Floor Level, e.g. Roof, 4TH, 3RD, 2ND <br />Lt-Rt Load Direction, e.g. Left -Right, Front -Rear <br />(For Left Wall, Use Front -Rear Load Direction) <br />COX Sheathing type (T4.3A of SDPWS-2015) <br />F—R-0-0—F-I Resisting Dead Load <br />Shearwall Segment Lengths: Adt. Total LengM = s s ft <br />3.5 ft 1 3.5 R <br />IV (ROOF) = <br />2110 lb <br />IV () = <br />0 lb <br />iV () = <br />0 lb <br />FV()= <br />0lb <br />7 (Wind) = <br />2,110 lb <br />ULT. v = <br />162 PLF <br />1775 lb <br />0 lb <br />0 lb <br />0 lb <br />i (Smc) = 1,775 lb <br />ULT. V = 137 PLF <br />ASD SHEAR WALL DESIGN PER: AFBPA SDPWS-2015 <br />ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF 1(2 x 0.6) = 499 PLF <br />ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF 1(2 x 0.7) = 306 PLF <br />Holdown Above: I NO FLOOR A80VE <br />ASD C. TOTAL = (floor above) + (this floor) = <br />ASD T. TOTAL w/o 00 = (floor above) + (this floor) = <br />r.__....... -.... _........ ..... ................ ..._._..._._........._...__........_..._...._...._..._............._..............._....... - ....._..__.,.._..., <br />Unfactored C. WL = 1461 Ibs Unfactored T WL = 1699 Ibs <br />Unfactored C. EQ = 1229 Ibs Unfactored T EQ = 1229 Ibs <br />Unfactored C. DL = 1125 Ibs Unfactored C LUSL = 938 Ibs <br />Floor Info <br />ROOF I Floor Level, e.g. Roof, 4TH, 3RD, 2ND <br />Lt-Rt Load Direction, e.g. Left -Right, Front -Rear <br />(For Left Wail, Use Front -Rear Load Direction) <br />CDX Sheathing type (T4.3A of SDPWS-2015) <br />ROOF Resisting Dead Load <br />Shearwall Segment Lengths: Adj. Total Length <br />3.0 R <br />EV (ROOF) = <br />2110 lb <br />TV ()= <br />0lb <br />EV()= <br />0lb <br />IV ()= <br />0lb <br />f (Wind) = <br />2.110 lb <br />ULT. v = <br />402 PLF <br />1775 lb <br />0 lb <br />0 lb <br />0 lb <br />i (Smc) = 1,775 lb <br />ULT. V = 336 PLF <br />ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 <br />ULT. WIND CAPACITY: 1.4 x 0.93 x 720 PLF / (2 x 0.6) = 781 PLF <br />ULT. SEISMIC CAPACITY: 1 x 0.93 x 720 PLF / 2 x 0.7) = 470 PLF <br />Holdown Above: F NO FLOOR ABOVE <br />ASD C. TOTAL = (floor above) + (this floor) = <br />ASD T. TOTAL w/o 00 = (floor above) + (this floor) = <br />Unfactored C WL = 3617 Ibs Unfactored T. WL = 3846 Ibs <br />Unfactored C. EQ = 3043 Ibs Unfactored T EQ = 3043 Ibs <br />Unfactored C. DL = 1080 Ibs Unfactored C,LL/SL = 900 Ibs <br />Tributary Area (ROOF) <br />1 0 Itributary area <br />2 0 total area <br />Tributary Area (2ND) <br />tributary area <br />total area <br />z Tributary Area (NA) <br />tributary area <br />_3 F total area <br />u Tributary Area (NA) <br />`^ tributary area <br />w <br />Ul total area <br />Weight of Shearwall = 10 0 Ibs <br />Tributary width for dead load = 6.0 ft <br />Length of adjoining wall = 4 5 ft <br />R = 6.5 <br />LRFD Holdown Design? No Ro = 1 2.5 <br />Ductile Anchor Design? No Block Shear Wall <br />USE 1 <br />Seismic contrris shearwall design <br />0 Ibs + 1011 Ibs = 1011 Ibs Seismic controls -C3 (ASD eq. 8). <br />0 Ibs + 345 Ibs = 345 ibs Wind controls -T1 (ASD eq 7): <br />NO HOLDOWNS REQUIRED OK <br />FOUNDATION / INTERIOR WALLS: OK <br />Tnbutary Area (ROOF) <br />t 0 tributary width <br />2.0 total width <br />Tributary Area (2ND) <br />tributary width <br />total width <br />Tributary Area (NA) <br />Z tributary width <br />0 <br />c total width <br />O <br />a Tributary Area (NA) <br />tributary width <br />3 total width <br />Height of Shearwall = 9 0 ft <br />Length of Shearwall = 1 3 0 ft <br />Aspect Ratio OK <br />Tributary Area (ROOF) <br />t 0 tributary width <br />2 0 total width <br />Tributary Area (2ND) <br />tributary width <br />total width <br />Tributary Area (NA) <br />Z tributary width <br />0F:�] <br />`t total width <br />O <br />o Tributary Area (NA) <br />z tributary width <br />3 total width <br />Height of Shearwall = 9,0 ft <br />Length of Shearwall = 1 3.5 ft <br />Aspect Ratio O`( <br />Tributary Area (ROOF) <br />[ :RF]total <br />tributary area <br />area <br />Tributary Area (2ND) <br />tributary area <br />total area <br />z Tributary Area (NA) <br />a tributary area <br />total area <br />Tributary Area (NA) <br />`^ tributary area <br />w <br />"'I Itotal area <br />Weight of Shearwall = 10 0 Ibs <br />Tributary width for dead load = 6 0 ft <br />Length of adjoining wall = 4.5 ft <br />R = 6.5 <br />LRFD Holdown Design? No no = 2.5 <br />Ductile Anchor Design? No Block Shear Wall <br />USE 2� <br />^t is rrri�r c ntrot:s 3h►„wwad design <br />0 Ibs + 2275 Ibs = 2275 Ibs Seismic controls -C3 (ASD eq. 8) <br />0 Ibs + 1660 Ibs = 1660 Ibs Wind controls -T1 (ASD eq 7): <br />SIMPSON DESIGNED HOLDOWM <br />FOUNDATION / INTERIOR WALLS: <br />