Laserfiche WebLink
�� <br />j <br />V <br />Janet R. Soriano D + <br />F= <br />Plan Check Number: 62108-011, First Building Review <br />September 28, 2021 OCT 12 2021 <br />General CITY OF EVERETT <br />Permit Services <br />1. Throughout the plan set multiple references of previous versions of the code should be updated <br />to reference the current code. See Sheet 3, 4, and S-1.0. <br />NV <br />2. See Sheet 4 and 5-1.0. Seismic data on Sheet 4 doesn't match info on S-1.0. <br />WNW - <br />Architectural <br />1. Safety glazing should be specified where required per IRC Section R308.4. Glazing adjacent and <br />within 24 inches of the swinging door should be specified as safety glazing. See entry door to <br />living room. �b 4ea <br />2. Continuing with the previous comment, safety glazing should be specified where glazing is less <br />than 36 inches above the plane of the adjacent walking surface of stairways and within 36 <br />inches measured horizontally of stairways. R308.4.6 �, �,,c�--•, <br />0 AZ U t'P6P-- to- t--6 <br />3. A note should be iadded specifying1 that smoke alarms to be interconnected per section R314.4 <br />4. A note should be added specifying that carbon monoxide alarms to be interconnected per <br />section R315.5 N 4f�� ' <br />5. See Sheet 1. Plans should specify 6x6 pressure treated posts for the exterior posts that are <br />embedded into the deep footing per 4/S5. R317.1.2 <br />6. Crawl spaces under buildings should be provided with ventilation per IRC Section R408.1. <br />7. The a di ion should be designed to comply with the additional energy efficiency requirements„ <br />Section R406 of the Washington State Energy Code. The architectural drawings should include a <br />schedule listing the selected energy credits for the proposed project. <br />tom"_, ;'ti'�.�.� �► i,�� A-�'� � � �..�'`�v � '��r�''"' �� �'7 <br />8. Plans should include a demo plan clearly showing existing walls to be removed. It is unclear <br />what framing is being removed to extend the living room. R106.1.1 ` <br />v41*n-1 1'� 6 L, (\I t U 67 V-H, OAL4...- 160 e!w <br />9. See Sheet 3. A Deck Plan is provided but it is unclear of the location of the deck with respect to e.k; <br />the existing house. R106.1.1 ���, �►� I oe�51 <br />10. See Sheet 1. Provide a section cut that starts4aothe deck fndp%J4ndstair <br />landing/existing wall. The section cut should show all existing and new framing elements which <br />include the roof framing, deck framing, stair framing, stair landing framing, 1st and 2nd floor <br />framing and connections. R106.1.1 Sr"r <br />11. See Sheet 3. Whole house ventilation tables should be updated to current code requirements. <br />See Section M 1505.4.3. Z01 P <br />> <br />12. Plans should include a calculation for the minimum area of roof ventilation per R806.2. <br />n} 3200 Cedar Street 425.257.8310 everetteps@everettwa.gov <br />\�� Everett, WA 98201 ��J 425.257.8857 fax everettwa.gov/permits <br />