Laserfiche WebLink
GENERAL NOTES AERIAL VIEW <br /> CODE AND STANDARDS <br /> "ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 INTERNATIONAL BUILDING CODE BLUE RAVEN <br /> (IBC),2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND ALL STATE , <br /> AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. <br /> 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. ` <br /> 1403 N. Research Way <br /> SITE NOTES/OSHA REGULATION Orem, UT 84097 <br /> 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 800.377.4480 <br /> 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. WWW.BLUERAVENSOLAR.COM <br /> 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. <br /> 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND CONFIDENTIAL-THE INFORMATION <br /> THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT HEREIN CONTAINED SHALL NOT BE <br /> THE BUILDING OR STRUCTURE. USED FOR THE BENEFIT OF ANYONE <br /> EXCEPT BLUE RAVEN SOLAR NOR <br /> SHALL IT BE DISCLOSED IN WHOLE OR <br /> SOLAR CONTRACTOR IN PART TO OTHERS OUTSIDE <br /> 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. RECIPIENTS ORGANIZATION,EXCEPT <br /> 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER IN CONNECTION WITH THE SALE AND <br /> THE MANUFACTURER'S INSTALLATION REQUIREMENTS. USE OF THE RESPECTIVE EQUIPMENT, <br /> 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF 00 WITHOUT THE WRITTEN PERMISSION <br /> STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. OF BLUE RAVEN SOLAR LLC. <br /> 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO <br /> LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. <br /> 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A NABC E P <br /> SUITABLE SEALING COMPOUND. <br /> 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. CERTIFIED] <br /> 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. _ <br /> 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT PV INSTALLATION <br /> AVAILABLE. <br /> 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC PROFESSIONAL <br /> PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND ` Scott Gurney <br /> CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND #PV-011719-015866 <br /> LISTED FOR THE APPLICATION PER NEC 690.4(B). <br /> 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. CONTRACTOR: <br /> 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) ` BRS FIELD OPS <br /> IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. • <br /> 800-377-4480 <br /> EQUIPMENT LOCATIONS <br /> 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT <br /> WILL BE PROVIDED AS PER SECTION NEC 110.26. <br /> 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS <br /> SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). A U <br /> 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC • Q U <br /> APPLICABLE CODES. Z > Q <br /> 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. O >� <br /> C) N <br /> PROJECT INFORMATION: <br /> ' Q CV ti M <br /> 00 <br /> 5 L1ND ya <br /> NUMBER OF STORIES: 1 ���+ 1ND LLU Ijj <br /> CONDUIT RUN: Interior H� O N N <br /> ECOBEE QTY: 1 y _ i _ :• C: U) N <br /> LIGHT BULB QTY: 18 >, <br /> PV METER: Not Required o �T sto w� ESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX n - > y <br /> ROOF TYPE (1) INFORMATION: �F8 RAL B� G� WIND SPEED: 110 mph CONSTRUCTION -V-B PV1 -COVER SHEET N C1) N >_ >_ <br /> ROOF TYPE: Comp Shingle %NAL�� GROUND SNOW LOAD: 15 Ib/ft' ZONING: RESIDENTIAL PV2-SITE PLAN U) >,M L Cl) N <br /> FRAMING TYPE: Rafter :3co N U V <br /> WIND EXPOSURE FACTOR: C PV3- ROOF PLAN M > <br /> SHEATHING TYPE: PLYWOOD V N W Q 0 <br /> ATTACHMENT: SFM Infinity Flashkit 08/23/2023 SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL <br /> PV5- ELECTRICAL LINE DIAGRAM <br /> PV6- ELECTRICAL C <br /> RACKING: Unirac SFM Infinity @ 48" OC Portrait/72"OC Landscape <br /> CALCULATIONS DRAWING BY: <br /> NUMBER OF ATTACHMENTS: 33 SCOPE OF WORK <br /> PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore <br /> ROOF TYPE (2) INFORMATION (IFAPPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHER SHEETS AS REQUIRED) <br /> *SEE PV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SS- PRODUCT SPEC. SHEETS PLOT DATE: <br /> August 22, 2023 <br /> PROJECT NUMBER: <br /> SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: 809827 <br /> DC SYSTEM SIZE: 6.3 kW DC Snohomish County Public Utilities District <br /> Firm License Number:2202 VSE Project Number:U2001.3013.231 SHEET NAME: <br /> AC SYSTEM SIZE: 4.725 kW AC � (PUD) <br /> MODULE TYPE: (15) REC Solar REC420AA PURE-R Vector Structural Engineering has reviewed the existing COVER SHEET <br /> INVERTER TYPE: Enphase IQ7X-96-2-US V E CTO R structure with loading from the solar array and screw <br /> connections to the existing framing.The design of the <br /> MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 E n O I n E E R S racking system,racking connections,and all other PERMIT ISSUER: REVISION: PAGE NUMBER: <br /> structural is by others.Mechanical,architectural,and all <br /> ss 1 W.BALENA PARK BLVD.STE. 101 PHONE(80 7)990-1775 other nonstructural aspects of the design are by others. City Of Everett 0 P V 1 <br /> DRAPER, UTAH 84020 WWW.VECTORSE.com Electrical is by others,unless stamped by Dean Levorsen. <br />