My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2319 GALE PL 2023-10-31
>
Address Records
>
GALE PL
>
2319
>
2319 GALE PL 2023-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2023 11:02:50 AM
Creation date
10/25/2023 6:22:31 AM
Metadata
Fields
Template:
Address Document
Street Name
GALE PL
Street Number
2319
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JB- 1 .2 E SOLAR PHONE: 385-202-4150 <br /> EZf SOLAR Specification Sheet making solarslmpio, WWW.EZSOLARPRODUCTS.COM <br /> BLUE RAVEN <br /> making solar simple PV Junction Box for Composition/Asphalt Shingle Roofs <br /> 1403 N.Research Way <br /> Orem,UT 84097 <br /> A. System Specifications and Ratings ITEM NO. PART NUMBER DESCRIPTION QTY SIZE DWG.NO REV <br /> 800.377.4480 <br /> POLYCARBONATE WWW.BLUERAVENSOLAR.COM <br /> • Maximum Voltage: 1,000 Volts 1 JB-12 BODY 1 CONFIDENTIAL-THE INFORMATION <br /> WITH UV INHIBITORS SCALE:1:2 WEIGHT:1.45 LBS SHEET 1 OF 3 HEREIN CONTAINED SHALL NOT BE <br /> • Maximum Current: 80 Amps USED FOR THE BENEFIT OF ANYONE <br /> EXCEPT BLUE RAVEN Allowable Wire: 14 AWG -6 AWG 2 <br /> JB 1.2 LID POLYCARBONATE 1 SHALL IT BE DISCLOSEDSINN WHO E NOR <br /> WITH UV INHIBITORS TORQUE SPECIFICATION: 15-20 LBS IN PART TO OTHERS OUTSIDE <br /> • RECIPIENTS ORGANIZATION,EXCEPT <br /> Spacing: Please maintain a spacing of at least 1/2" between uninsulated live arts and fittings for <br /> p g p g IN CONNECTION WITH THE SALE AND <br /> conduit, armored cable, and uninsulated live parts of opposite polarity. #10 X 1-1/4"PHILLIPS ULSTANDARD 1741, USE OF THE RESPECTIVE EQUIPMENT, <br /> THE WRITTENSION <br /> Enclosure Rating: Type 3R 3 PAN HEAD SCREW 6 CERTIFICATION: NEMA 3R WIT OFUBLUE RAVEN SOLAR PERMIC <br /> 9� Yp . <br /> ' <br /> • Roof Slope Range: 2.5- 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS NABCEP <br /> • Max Side Wall Fitting Size: 1" PAN HEAD SCREW <br /> • Max Floor Pass-Through Fitting Size: 1" 1 CERTIFIED <br /> • Ambient Operating Conditions: (-35°C) - (+75°C) PV INSTALLATION <br /> • Compliance: PROFoESSIONAL <br /> tt Gurney <br /> - J13-12 UL1741 #PV-011719-015866 <br /> -Approved wire connectors: must conform to UL1741 CONTRACTOR: <br /> • System Marking: Interek Symbol and File #5019942 BRS FIELD OPS <br /> • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion 385-498-6700 <br /> between components, components that are found to be affected are to be replaced immediately. <br /> Table 1:Typical Wire Size,Torque Loads and Ratings <br /> Torque <br /> 1 Conductor 2 ConductorType NM htch Lbs Voltage Current - <br /> ABB Z56 terminal block 10-24 awg 16-24 awg Sol/Str 0.".7 6.2-8.8S 600V 30 amp <br /> ABB ZS30 terminal block 6.24 awg 12-20,awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 am <br /> ABB ZS16 terminal bock 4.24 awl, 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 am <br /> ABB M6/8 terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp 127 1.01 in ] [27 0.0 n <br /> i I.01 in 10.88in , <br /> Ideal 452 Red WING-NUT Wire 8-1&awg Sol/Str Self Torque Self Torque 600V <br /> Connector I /� [� <br /> Ideal 451 Yellow WING-NUT 10-18 awg Sal/Str Self Torque Self Torque 600V SOLAR <br /> W ire Connectof <br /> Ideal,In-SurePush4n 10.14 awg Sol/Str Self Torque Self Torque 600V <br /> Connector Part#39 JB-1.2 <br /> WAGO,2204-1201 10-20 awg 16 24 awg Sol/Str Self Torque Sell Torque 600V 30 arnp <br /> WAGO,221-612 10-20 awg 10-24 awg Sol/Str Self Torque Sol!Torque 600V 30 amp i <br /> DottieDRC75 6-12 awg Sol/Str Snap-In Snapdn ! <br /> ESP NG-53 4-6 awgSol/Str 45 2000V <br /> 10.14 awg Sol/Sir 35 <br /> j <br /> ESP NG-717 4,6 X'g Sol/Str 45 2000V - <br /> 10,14awg Sol/Str 35 DRAWING BY: <br /> Brumal14-5.3 4-6awg Sol/Str 45 2000V <br /> 1014 awa Sol/Str 3s [183.06mmf i 72.53mm <br /> 7.21 in 2.86in PLOT DATE: <br /> Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) [265.18mm] <br /> Wire size,AWG or Wires per terminal(pole) 10.44in <br /> 1 2 3 4 or More PROJECT NUMBER: <br /> kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) <br /> 14-10 (2.1-5.3) Not specified - - <br /> 8 (8.4) 38.1 (1-1/2) SHEET NAME: <br /> 6 (13.3) 50.8 (2) SPEC SHEET <br /> REVISION: PAGE NUMBER: <br /> EZtSOLAR PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM PROPRIETARYAND CONFIDENTIAL:THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTYOF EZ SOLAR. ---- SS <br /> ANY REPRODUCTION IN PARTOR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. <br />
The URL can be used to link to this page
Your browser does not support the video tag.