My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4815 BAKER DR 2023-10-25
>
Address Records
>
BAKER DR
>
4815
>
4815 BAKER DR 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 8:25:18 AM
Creation date
10/25/2023 7:00:50 AM
Metadata
Fields
Template:
Address Document
Street Name
BAKER DR
Street Number
4815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ip /� <br /> 2 �U • <br /> Washington State Energy C/�ode''Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> N Single Family '' ew &Additions (effective February 1,2021) <br /> Table 406.3*'Energy Credits (Single Family) <br /> Option Description Credits: SF <br /> 1. EFFICIENT BUILDING ENVELOPE OPTIONS <br /> Only one option from Items 1.1 through 1.7 may be selected in this category. <br /> Compliance with the conductive UA targets is demonstrated using Section R402.1.4, Total UA alternative, where [1- <br /> (Proposed UA/Target UA)] >the required %UA reduction. <br /> 1,1 Prescriptive compliance is based on Table R402.1.1 with the following modifications: 0.5 <br /> Vertical fenestration U =0.24 <br /> 1 2 Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.0 <br /> Vertical fenestration U =0.20 <br /> Prescriptive compliance is based on Table R402.1,1 with the following modifications: <br /> Vertical fenestration U =0.28 <br /> Floor R-38 <br /> 1.3 Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and 0.5 <br /> under entire slab or <br /> Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.25 <br /> Wall R-21 plus R-4 ci <br /> Floor R-38 <br /> 1.4 Basement wall R-21 int plus R-5 ci 1.0 <br /> Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and <br /> under entire slab or <br /> Compliance based on Section R402.1.4: Reduce the Total conductive UA by 15% <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.22 <br /> Ceiling and single-rafter or joist-vaultedR-49 advanced <br /> Wood frame wall R-21 int plus R-12 ci Floor R-38 <br /> 1.5 Basement wall R-21 int plus R-12 ci 2.0 <br /> Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and <br /> under entire slab or <br /> 1 Compliance based on Section R402.1.4: Reduce the Total conductive UA by 30% <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.18 <br /> Ceiling and single-rafter or joist-vaultedR-60 advanced <br /> Wood frame wall R-21 int plus R-16 ci <br /> 1.6 Floor R-48 3.0 <br /> Basement wall R-21 int plus R-16 ci <br /> Slab on grade R-20 perimeter and under entire slab Below grade slab R-20 perimeter and <br /> under entire slab or <br /> Compliance based on Section R402.1.4: Reduce the Total conductive UA by 40%. <br /> Advanced framing and raised heel trusses or rafters <br /> Vertical Glazing U-0.28 <br /> 1.7 R-49 Advanced (U-0.020) as listed in Section A102.2.1, Ceilings below a vented attic and 0.5 <br /> R-49 vaulted ceilings with full height of uncompressed insulation extending over the wall <br /> top plate at the eaves. <br /> Prescriptive Path—Single Family 2018 Washington State Energy Code-R 4 ;.3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.