Laserfiche WebLink
Permit Inspections <br />VERETT City of Everett <br />WASHINGTON <br />Permit Number: P2220-031 <br />Applied: 10/19/2022 Approved: 10/24/2022 <br />Issued:10/26/2022 Finaled: 7/14/2023 <br />Status: FINALED <br />Parent Permit 32112A 52 <br />Parent Project <br />Details: <br />addition remodel <br />Description: PLUMBING FOR ADDN /REMODEL <br />Site Address: 1011 GRAND AVE <br />City, State Zip Code: EVERETT, WA <br />Applicant: Kalil Bolling <br />Owner: WERTHEIMER CLAY M & HELEN P <br />Contractor JET PLUMBING LLC <br />LIST OF INSPECTIONS <br />SCHEDULEDDATE COMPLETEDDATE <br />TYPE <br />INSPECTOR RESULT REMARKS <br />10/31/2022 <br />10/31/2022 <br />PLUM103-ROUGH <br />IASON CORRECTION see notes <br />IN <br />MORRISSEV REQUIRED <br />Notes: <br />10127/20229:27 PM Kalil Bolling <br />Contact Name: Kelli Bolling <br />Site Address; 1011 GRAND AVE <br />Phone : 36065978M <br />e-Mail'. jetplumbing.W@gmail.com <br />-Non code horizontal wetventsWmmmmn floor 3/4 bath. The hgdzontal we vent system is for fixtures within bathr00m only. All otberfixtures <br />outside bathroom musthe In downstream of the hodzonGl wetvem sysem perchap.9 2018 UPC. 908.2S Additional Fixtures -Trap arm for toilet <br />seeds 6' limit set in chap 30 of the 2018 UPC. Trap arm for toilet is measured from the flange to the nearest edge of the vent. Install deanoulson all <br />horizontal blanch drains exceeding 5' per chap ) 2018 UK, Including a 3" end of line deans No test on waste far main bath, utility, sink and AW. <br />Need fixture Unit calculations Eased off dram 6 table 610.3 and 610.4. Water service appears undersized for 4 bath house with sprinkler system. Would <br />think 11/4"to 11/2'4 Need to prove water supply is adequate for rough plumbing approval. <br />-Downstairs lax trap arm exceeds 42". Trap arm is also backgroded. <br />11/15/2022 <br />11/15/2022 <br />PLUMB 03 ROUGH <br />IASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />11/11/2022 12:06 PM Kelli Bolling <br />Contact Name: quit Balling <br />Site Address: 1011 GRAND AVE <br />PM1one: 3606597885 <br />e-Mail:)etplumbing.kb@gmall.com <br />-Test has dropped again on DWV for new main floor bath plumbing. <br />11/15/2022 <br />11/15/2022 <br />PLUMB 08-FINAL <br />IASON <br />CORRECTION <br />see notes <br />MORRISSEY <br />REQUIRED <br />Notes. <br />-Due to water system being undersized them will be water flow test required at final where multiple fixtures are run simultaneously Including <br />sprinkler system to ensure water volume is sufficient fora higher demand scenario. 601.2 Hot and Cold Water acquired-610.4 Sizing Water Supply and <br />Distribution Systems-610.1 Size 105.2.2 Other Inspections <br />Printed: Friday, 141u1y, 2023 10f 2 i L <br />SVPEPION <br />