GENERAL NOTES AERIAL VIEW <br />CODE AND STANDARDS <br />1. ALL WORK SHALL COMPLY WITH 2O17 NATIONAL ELECTRIC CODE (NEC), 2015 INTERNATIONAL BUILDING CODE 0 <br />(IBC), 2015 INTERNATIONAL RESIDENTIAL CODE (IRC), 2015 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE <br />AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES. <br />2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. ► <br />SITE NOTES / OSHA REGULATION <br />1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. <br />2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. <br />3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. <br />4. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND �• <br />THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT <br />THE BUILDING OR STRUCTURE. <br />SOLAR CONTRACTOR imp • <br />1. MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. <br />2. IF APPLICABLE, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER _ <br />THE MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />3. AS INDICATED BY DESIGN, OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF 1 <br />STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. • <br />4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO <br />LIMIT UP -SIZING AS REQUIRED BY FIELD CONDITIONS. <br />5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A = <br />SUITABLE SEALING COMPOUND. <br />6. DC WIRING LIMITED TO MODULE FOOTPRINT W1 ENPHASE AC SYSTEM. <br />7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W1 SUITABLE WIRING CLIPS. <br />8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT <br />AVAILABLE. <br />9. ALL INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC <br />PHOTOVOLTAIC MODULES, DC COMBINERS, DC -TO -DC CONVERTERS,SOURCE CIRCUIT COMBINERS, AND III YYY��u,nny _ <br />CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND l • `' ^ (�� �yy� <br />LISTED FOR THE APPLICATION PER NEC 690.4(B). IVJUI }`�-ryn•Jl`1/ <br />10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. <br />11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS (WHEN PROVIDED) • <br />IN ACCORDANCE WITH NEC CODE 110.14(D) ON ALL ELECTRICAL CONNECTIONS. <br />EQUIPMENT LOCATIONS <br />1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT <br />WILL BE PROVIDED AS PER SECTION NEC 110,26. <br />2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS ' <br />SPECIFIED BY NEC 690.31(A) AND NEC TABLE 310.15(B). <br />3. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC w <br />APPLICABLE CODES. ~ <br />4. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. <br />rl ' <br />PROJECT INFORMATION: '� �N 6 <br />NUMBER OF STORIES: 2 <br />CONDUIT RUN: Interior <br />ECOBEE QTY: 1 <br />LIGHT BULB QTY: 18 <br />CPVaMETE:RjN:ot=RequiredA <br />ROOF TYPE (1) INFORMATION: <br />ROOF TYPE: Comp Shingle <br />FRAMING TYPE: Manufactured Truss <br />SHEATHING TYPE: OSB <br />ATTACHMENT: SFM Infinity Switchblade Flashkit <br />RACKING: Unirac SFM Infinity @ 48" OC Portrait / 72" OC Landscape <br />NUMBER OF ATTACHMENTS: 37 <br />ROOF TYPE (2) INFORMATION (IFAPPLICABLE): <br />*SEE PV4.2 <br />SYSTEM TO BE INSTALLED INFORMATION: <br />DC SYSTEM SIZE: 5.53 kW DC <br />AC SYSTEM SIZE: 4.06 kW AC <br />MODULE TYPE: (14) QCells Q.PEAK DUO BILK ML-G10+ 395 <br />INVERTER TYPE: Enphase IQ8PLUS-72-2-US <br />MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 <br />DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX <br />WIND SPEED: 110 mph CONSTRUCTION - V-B PV1 - COVER SHEET <br />GROUND SNOW LOAD: 15 Ib/ft2 ZONING: RESIDENTIAL PV2 - SITE PLAN <br />WIND EXPOSURE FACTOR: C PV3 - ROOF PLAN <br />SEISMIC DESIGN CATEGORY: D PV4 - STRUCTURAL <br />PV5 - ELECTRICAL 3-LINE DIAGRAM <br />SCOPE OF WORK PV6 - ELECTRICAL CALCULATIONS <br />PV7 - WARNING LABELS AND LOCATIONS <br />INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHER SHEETS AS REQUIRED) <br />NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SS - PRODUCT SPEC. SHEETS <br />(UTILITY COMPANY: <br />Snohomish County Public Utilities District <br />(PUD) A <br />PERMIT ISSUER: <br />City of Everett <br />No - <br />BLUE RAVEN <br />1403 N. Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W.BLUERAVENSOLAR.COM <br />CONFIDENTIAL- THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NABCEP <br />CERTIFIED <br />PV INSTALLATION <br />PROFESSIONAL <br />Scott Gurney <br />#PV-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OPS <br />800-377-4480 <br />Q <br />Z <br />p <br />o <br />Q <br />ONO <br />CDLO <br />M <br />�r L6 <br />C <br />o <br />W <br />LL_ <br />N N <br />Z <br />�j <br />Cn Cl) <br />U) <br />U) <br />WC>� <br />0 <br />WW <br />U)U) <br />O <br />��� <br />� <br />N Cl) <br />vcnrnw <br />Qo <br />DRAWING BY: <br />Eric Thomas <br />PLOT DATE: <br />December 20, 2022 <br />PROJECT NUMBER: <br />673276 <br />SHEET NAME: <br />COVER SHEET <br />REVISION: PAGE NUMBER: <br />A PV1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.