STANDARD LABELS ADDITIONAL LABELS I <br />OWARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />RATED AC OUTPUT CURRENT 16.94 A <br />NOMINAL OPERATING AC VOLTAGE 240 V <br />OWARNING <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />OWARNING 1 <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />DEVICE <br />OWARNING <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />.OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />LABELING NOTES <br />BLUE RAVEN <br />LABEL 1 <br />LABEL 8 <br />PV SYSTEM DISCONNECTING MEANS WHERE THE <br />WFOR <br />O ARNING <br />PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br />LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE <br />LOCATION OF ALL ELECTRIC POWER SOURCE <br />OPEN POSITION. <br />MAIN DISTRIBUTION UTILITY DISCONNECT(S) <br />DISCONNECTING MEANS ON OR IN THE PREMISES <br />1403 N. Research Way <br />(2017 NEC 690.13(8)1 <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT <br />Orem, UT 84097 <br />(2020 NEC 690.13(8)1 <br />FROM A ROOF MOUNTED SOLAR ARRAY WITH <br />LOCATION AND AT THE LOCATION(S) OF THE SYSTEM <br />800.377.4480 <br />A RAPID SHUTDOWN DISCONNECTING MEANS <br />DISCONNECT(S) FOR ALL ELECTRIC POWER <br />WWW.BLUERAVENSOLAR.COM <br />GROUPED AND LABELED WITHIN LINE OF SITE <br />PRODUCTION SOURCES CAPABLE OF BEING <br />AND 10 FT OF THIS LOCATION <br />INTERCONNECTED. <br />CONFIDENTIAL- THE INFORMATION <br />[2017 NEC 705.10] <br />HEREIN CONTAINED SHALL NOT BE <br />[2020 NEC 705.10] <br />USED FOR THE BENEFIT OF ANYONE <br />LABEL 2 <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />THE DISCONNECTING MEANS AS A POWER SOURCE <br />�� <br />LABEL 9 <br />IN PART TO OTHERS OUTSIDE <br />AND WITH THE RATED AC OUTPUT CURRENT AND THE <br />WARNING <br />PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />NOMINAL OPERATING AC VOLTAGE. <br />LOCATION OF ALL ELECTRIC POWER SOURCE <br />(2017 NEC 690.541 <br />USE OF THE RESPECTIVE EQUIPMENT, <br />(2020 NEC 690.541 <br />POWER TO THIS BUILDING IS ALSO <br />DISCONNECTING MEANS ON OR IN THE PREMISES <br />WITHOUT THE WRITTEN PERMISSION <br />SUPPLIED FROM MAIN DISTRIBUTION <br />SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT <br />OF BLUE RAVEN SOLAR LLC. <br />LOCATION AND AT THE LOCATION(S) OF THE SYSTEM <br />UTILITY DISCONNECT LOCATED <br />DISCONNECT(S) FOR ALL ELECTRIC POWER <br />PRODUCTION SOURCES CAPABLE OF BEING <br />INTERCONNECTED. <br />NABCEP <br />LABEL 3 <br />(2017 NEC 705.101 <br />IF INTERCONNECTING LOAD SIDE, INSTALL THIS LABEL <br />[2020 NEC 705.10] <br />CERTIFIED <br />ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br />AND THE SOLAR PV SYSTEM, IE. MAIN SERVICE PANEL <br />AND SUBPANELS. <br />PV INSTALLATION <br />LABEL 10 <br />[2017 NEC 705.12(B)(3)] <br />PROFESSIONAL <br />(2020 NEC 705.12(8)(3)] <br />WARNING <br />L <br />PERMANENT PLAQUE DIRECTORY TO BE <br />VI <br />LOCATED AT MAIN SERVICE EQUIPMENT DENOTING <br />Scott Gurney <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />THE LOCATION OF THE RAPID SHUTDOWN SYSTEM <br />#PV-011719-015866 <br />DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br />FROM A ROOF MOUNTED SOLAR ARRAY. SOLAR <br />SHUTDOWN DISCONNECTING SWITCH IS NOT <br />CONTRACTOR: <br />LABEL 4 <br />ARRAY RAPID SHUTDOWN DISCONNECT IS <br />GROUPED AND WITHIN LINE OF SITE OF MAIN <br />BRS FIELD OPS <br />APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT <br />LOCATED OUTSIDE NEXT TO THE UTILITY METER. <br />SERVICE DISCONNECTING MEANS. <br />800-377-4480 <br />TO THE BACK -FED BREAKER FROM THE POWER <br />[2017 NEC 705.10 AND 690.56(C)(1)(a)] <br />[2020 NEC 705.10 AND 690.56(C)] <br />SOURCE. <br />(2017 NEC 705.12(8)(2)(3)(b)] <br />(2020 NEC 705.12(8)(3)(2)] <br />WARNING LABEL 11 <br />I PERMANENT PLAQUE OR DIRECTORY TO BE <br />LOCATED AT AC COMBINER PANEL. <br />PHOTOVOLTAIC SYSTEM [2017 NEC 110.21(8)] <br />LABEL 5 COMBINER PANEL [2020 NEC 110.21(8)] <br />APPLY TO THE PV COMBINER BOX <br />[2017 NEC 705.12(8)(2)(3)(c)] DO NOT ADD LOADS <br />(2020 NEC 705.12(8)(3)(3)] <br />LABEL 6 <br />BUILDINGS WITH PV SYSTEMS SHALL HAVE A <br />PERMANENT LABEL LOCATED AT EACH SERVICE <br />EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS <br />ARE CONNECTED OR AT AN APPROVED READILY <br />VISIBLE LOCATION AND SHALL INDICATE THE LOCATION <br />OF RAPID SHUTDOWN INITIATION DEVICES. <br />(2017 NEC 690.56(C)(1)(a)] <br />[2020 NEC 690.56(C)] <br />LABEL 7 <br />SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br />SWITCH <br />(2017 NEC 690.56(C)(3)] <br />(2020 NEC 690.56(C)(2)] <br />1) LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT <br />REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. <br />2) LABELING REQUIREMENTS BASED ON THE 2017 8 2020 NEC CODE, OSHA STANDARD 19010.145, ANSIZ535. <br />3) MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. <br />4) LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE <br />HANDWRITTEN [NEC 110.211 <br />SUBPANEL <br />UTILITY MAIN (IF INTERCONNECTION AC PV PV COMBINER <br />METER SERVICE PANEL IS MADE HERE) DISCONNECT METER BOX <br />*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br />REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br />MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE <br />DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />Qo <br />Z <br />Q <br />MO <br />00 <br />O LO <br />CQ <br />C <br />O <br />W Ijj <br />LL <br />0 <br />N N_ <br />Z <br />> <br />N > <br />Cn in <br />W <br />V) <br />U) <br />ca <br />M 2 <br />LU <br />W W <br />U) <br />O <br />co <br />� <br />0 <br />00 <br />a)Ln <br />N Cl)can <br />Ucnrnw <br />Q� <br />DRAWING BY: <br />Eric Thomas <br />PLOT DATE: <br />December 20, 2022 <br />PROJECT NUMBER: <br />673276 <br />SHEET NAME: <br />LABELS <br />REVISION: I PAGE NUMBER: <br />A I PV7 <br />