Laserfiche WebLink
making solar simple, <br />EZf SOLAR <br />JB-1.2 EZf SOLAR <br />Specification Sheet oraking solar slmple, <br />PV Junction Box for Composition/Asphalt Shingle Roofs <br />A. System Specifications and Ratings <br />• Maximum Voltage: 1,000 Volts <br />• Maximum Current: 80 Amps <br />• Allowable Wire: 14 AWG — 6 AWG <br />• Spacing: Please maintain a spacing of at least'/2" between uninsulated live parts and fittings for <br />conduit, armored cable, and uninsulated live parts of opposite polarity. <br />• Enclosure Rating: Type 3R <br />• Roof Slope Range: 2.5 — 12:12 <br />• Max Side Wall Fitting Size: 1" <br />• Max Floor Pass -Through Fitting Size: 1" <br />• Ambient Operating Conditions: (-35°C) - (+75°C) <br />• Compliance: <br />- JB-1.2: UL1741 <br />-Approved wire connectors: must conform to UL1741 <br />• System Marking: Interek Symbol and File #5019942 <br />• Periodic Re -inspections: If re -inspections yield loose components, loose fasteners, or any corrosion <br />between components, components that are found to be affected are to be replaced immediately. <br />Table 1: Typical Wire Size, Torque Loads and Ratings <br />1 Conductor <br />2 Conductor <br />Torque <br />Type <br />NM <br />Inch Lbs <br />Voltage <br />Current <br />ABB ZS6 terminal block <br />10-24 awg <br />16 24 awg <br />Sol/Str <br />O.S-0.7 <br />6.2-8.95 <br />600V <br />30 amp <br />ABB Z510 terminal block <br />6-24 awg <br />11-20 awg <br />Sol/Sir <br />1.0-1.6 <br />8.85-14.16 <br />600V <br />40 amp <br />ABB Z516 terminal bock <br />4.24 awg <br />10-20 awg <br />Sol/Str <br />1.6-2.4 <br />14 6-21.24 <br />600V <br />60 am <br />ABB M6/8 terminal block <br />8.12 awg <br />Sol/Str <br />.08-1 <br />8.85 <br />600V <br />SO amp <br />Ideal452 Red WING -NUT Wire <br />Connector <br />g 18 awg <br />Sol/Str <br />Self Torque <br />Self Torque <br />600V <br />Ideal 451 Yellow WING -NU I <br />WrreConnector <br />10 18 awg <br />Sol/Sty <br />Self Torque <br />Self torque <br />600ti <br />Ideal, In -Sure Push -In <br />Connector Part #39 <br />10.14 awg <br />Sol/Str <br />Self Torque <br />Sell Torque <br />6001✓ <br />WAGO, 2204-1201 <br />10-20 awg <br />16 24 awg <br />Sol/Str <br />Self Torque <br />Self Torque <br />600V <br />I 30.vnp <br />WAGO, 221.612 <br />10-20 awg <br />10 24 awp, <br />Sol/Str <br />Self Torque <br />Self Torque <br />600V <br />30 amp <br />DottieDRC75 <br />6 12 awg <br />Sol/Str <br />Snap In <br />Snap In <br />ESP NG-53 <br />,1 {6 awg <br />Sol/Str <br />45 <br />2000V <br />10.14 awg <br />Sol/Sir <br />35 <br />ESP NG-717 <br />4 6 awg <br />Sol/str <br />•15 <br />1000V <br />10.14 awE <br />Sol/Str <br />35 <br />Brumall4-S,3 <br />4-6awp <br />Sol/St' <br />45 <br />2000V <br />In 14awf: <br />Sol/Str <br />35 <br />Table 2: Minimum wire -bending space for conductors through a wall opposite terminals in mm (inches) <br />Wire size, AWG or <br />Wires per terminal (pole) <br />1 <br />2 <br />3 <br />4 or More <br />kcmil (mm2) <br />mm (inch) <br />mm (inch) <br />mm (inch) <br />mm (inch) <br />14-10 (2.1-5.3) <br />Not specified <br />- <br />- <br />8 (8.4) <br />38.1 (1-1/2) <br />6 (13.3) <br />1 50.8 (2) <br />ITEM NO. <br />PART NUMBER <br />DESCRIPTION <br />OTY <br />1 <br />JB-12 BODY <br />POLYCARBONATE <br />1 <br />WITH UV INHIBITORS <br />POLYCARBONATE <br />2 <br />JB-1.2 LID <br />WITH UV INHIBITORS <br />1 <br />3 <br />#10 X 1-1/4" PHILLIPS <br />6 <br />PAN HEAD SCREW <br />4 <br />48 X 3/4" PHILLIPS <br />PAN HEAD SCREW <br />6 <br />[279.e <br />11.1 <br />7.21in <br />[265.18mm] <br />10.44in <br />PHONE:385-202-4150 <br />WWW.EZSOLARPRODUCTS.COM <br />SIZE <br />B <br />DWG. NO <br />JB-1,2 <br />REV <br />SCALE:1:2 <br />WEIGHT:1.45 LBS <br />SHEET I OF 3 <br />TORQUE SPECIFICATION: <br />15-20 LBS <br />UL STANDARD 1741, <br />CERTIFICATION: <br />NEMA 311 <br />WEIGHT: <br />1.45 LBS <br />Nor -- <br />BLUE RAVEN <br />1403 N. Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W.BLUERAVENSOLAR.COM <br />CONFIDENTIAL- THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NABCEP <br />CERTIFIED <br />PV INSTALLATION <br />PROFESSIONAL <br />Scott Gurney <br />#PV-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OPS <br />385-498-6700 <br />DRAWING BY: <br />_ 172.53mm <br />2.86in PLOT DATE: <br />PROJECT NUMBER: <br />SPEC SHEET <br />EZtSOLAR <br />PHONE: 385-202-4150 1 WWW.FZSOLARPRODUCTS.COM <br />PROPRIETARY AND CONFIDENTIAL: THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTY OF EZ SOLAR. <br />ANY REPRODUCTION IN PARTOR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. <br />REVISION: PAGE NUMBER: <br />---- SS <br />