My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1710 W MARINE VIEW DR 2024-01-03
>
Address Records
>
W MARINE VIEW DR
>
1710
>
1710 W MARINE VIEW DR 2024-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 9:12:13 AM
Creation date
10/26/2023 3:14:28 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1710
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1335
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
H I I BALL <br />Ll VALVE <br />CHECK <br />VALVE - <br />- U <br />D G G D m <br />F a <br />E <br />B C t- G D <br />2" METERED WATER SERVICE <br />3 <br />0 <br />N <br />0 <br />U <br />I <br />N <br />g <br />La <br />W <br />d <br />x <br />0 <br />�L <br />W <br />1N <br />Ln <br />0 <br />0 <br />Ln <br />d <br />CL <br />0 <br />0-(IF THIS DRAWING IS NOT 22"04" SCALE ACCORDINGLY. <br />W <br />H <br />Q <br />a <br />I <br />NOTES <br />A. ROMAC, FORD OR MUELLER DOUBLE STRAP SERVICE SADDLE WITH I.P. THREAD TO BE USED ON ALL MAINS 4" DIA <br />AND LARGER. ALL NEW TAPS ON EXISTING WATER MAINS SHALL BE DONE BY THE CITY OF EVERETT UTILITIES <br />DEPARTMENT AT THE DEVELOPERS OR CONTRACTORS EXPENSE. <br />B. 2" BRASS NIPPLE. <br />C. HEAVY DUTY 2" GATE VALVE WITH RESILIENT SEAT AND 2" OPERATING NUT. GATE VALVES SHALL BE "WATEROUS" <br />SERIES 2500 OR CITY APPROVED EQUAL. <br />D. MUELLER H-154S1N OR H-1S428N OR APPROVED EQUAL. USE APPROPRIATE STAINLESS STEEL INSERT STIFFENER <br />WITH POLYETHYLENE TUBING. PHYSICAL BENDS IN POLY PIPE ARE NOT ALLOWED, USE BRASS ELBOWS. <br />E. RESIDENTIAL SERVICE <br />1. PROVIDE 2" POLYETHYLENE TUBING MEETING THE FOLLOWING REQUIREMENTS: <br />a. AWWA C901. <br />b. ASTM D2737, SIDR 9 (pe3608/4710). <br />c. ASTM 3350 - PE3608 OR PE4710. <br />2. PROVIDE A #10 AWG, SINGLE STRAND COPPER WIRE WITH BLUE TYPE OF OR USE COATING SUITABLE FOR <br />DIRECT BURY <br />a. WRAP WIRE AROUND TUBING, ONE WRAP PER FT, ITS ENTIRE LENGTH. <br />b. SECURE ONE END AROUND THE SADDLE BOLT BETWEEN TWO NUTS AND EXPOSE A MINIMUM OF 18" <br />OF THE OTHER END IN THE METER BOX. <br />F NON-RESIDENTIAL SERVICE <br />1 PROVIDE 2" TYPE K COPPER TUBING MEETING ASTM 988, ANSI/NSF 61 & APPLICABLE IAPMO STANDARDS. <br />G. BRASS ELBOWS & NIPPLES AS NEEDED. <br />H. METER SETTERS SHALL BE "FORD" 70 SERIES COPPER SETTER VBH77-128.11.77 WITH HORIZONTAL INLET AND <br />OUTLET OR APPROVED EQUAL, <br />I. METER SHALL BE SUPPLIED AND INSTALLED BY CITY UTILITIES DEPARTMENT AT THE DEVELOPERS OR CONTRACTORS <br />EXPENSE. <br />J. PROVIDE METER BOX BODY MANUFACTURED BY "RAVEN PRODUCTS, MODEL RMB-17-30-12", MOUSEHOLES CUT, <br />WITH AASTHO H-20 RATED DUCTILE IRON FLUSH SOLID COVER LID OR EQUAL. <br />K. PLACE SAWDUST IN METER BOX AROUND PIPE TO TOP OF METER TO PREVENT FREEZING. <br />L. ADJUSTABLE VALVE BOX AND EXTENSION SEE STD 505. <br />CITY OF EVERETT <br />PUBLIC WORKS DEPARTMENT <br />A'A'1 SA%l r.r.1 >._ 'A Ati. 03/06/2017 <br />METERED WATER SERVICES <br />21' 502 <br />SQUARE TO <br />CIRCULAR ROOF <br />DRAIN ADAPTOR <br />45' ELBOWS <br />BUILDING, SEE <br />ARCHITECTURAL <br />ROOF LEADER, CONCRETE <br />SEE ARCHITECTURAL SECTION <br />PVC DIAMETER <br />PER PLAN <br />TEE ROOF DRAIN <br />PER PLAN <br />ROOF DRAIN CONNECTION DETAIL <br />SCALE: 1 1/2" = 1'-0" <br />CLEANOUT PER CITY OF <br />EVERETT STANDARD PLAN 604 <br />:VATION <br />z <br />APPROVED <br />COUPLING <br />CONNECT TO EXISTING -\,_ 2% MIN. <br />PER COE STANDARDS SLOPE <br />6" PVC ASTM D3034, SDR35, <br />OR AWWA C900, TYP. <br />SANDBAG FILLED WITH 60LBS <br />MINIMUM DRY MIX CONCRETE <br />SEWER MAIN (OR CONCRETE BLOCK) <br />DUMPSTER SEWER SERVICE <br />SCALE: 1/2" = 1'-0' <br />PROJECT ENGINEER: SCALE: DWG. NO. <br />a� PND ENGINEERS, INC. IS NO- RESPONSIBLE FCR SAFETY J. KEISER NOTED PORT OF EVERETT C3.�2 <br />z l PROGRAMS, METHODS OR PROCEDURES OF OPERATION, OR THE 8RI1CF PORT G A R D N E R LANDING `I <br />Port of CONSTRUCTION OF THE CCSIGN SHOWN ON TH-SE DRAWINGS. 4pEowws"'c s DESIGNED BY DATE <br />wt° 3240FAsdakcAwnucE WHERE SPECIFICAT DNS ARF GFNFRAI CR NOT CAL_ED OUT, g �p W. THOMPSON MARCH 2O22 CIP NO. <br />g ® m Sca[tic, l%'ashingon 98102 -HE SPEC( -(CATIONS SHALL CONFORM TO STANDARDS OF BUILDING 6-8-025-Ot <br />.111 EVERETT P.-206.624.1387 INDUSTR". CRAWNGS ARF FOR USE ON THIS PROJECT ONLY DRAWN 8v: CHECKED BY: <br />Nin ENGINEERS, INC. w .podcrpnecn.com AND ARE NOT INTENDED FOR REUSE WITHOUT WRITTEN i 1F 2709 Ec �� G. DEAN C. CASTONA PROJECT <br />N P.O. BOX 538 QD 3/31/22 JBK 100x ISSUED FOR PERMIT V ANYAPPROVAL FROR PND. WOULD ONSTIn WINGS ARE ALSO A NOT TO TRIMENEE USED `�SS/0 S'E~(���\ APPROVED BY: <br />NO. PD-SM-2021-D7 <br />N EWKTT, WA 98206 N A l <br />n i[ (425) 259-3164 DIRECTLY OR INDIRECTLY TO PND. <br />NO. DA-E BY REVISICN UTILITY DETAILS [SHEET NO. 24 OF 97 <br />
The URL can be used to link to this page
Your browser does not support the video tag.