My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7718 CASCADE DR 2023 Plans 2024-06-11
>
Address Records
>
CASCADE DR
>
7718
>
Plans
>
7718 CASCADE DR 2023 Plans 2024-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 1:58:12 PM
Creation date
10/27/2023 11:18:11 AM
Metadata
Fields
Template:
Address Document
Street Name
CASCADE DR
Street Number
7718
Permit
B2309-030
Year
2023
Notes
REMODEL, KITCHEN ELEVATION CHANGE, REBUILD WALLS, PAINT, ETC.
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WA Residential Code 2018 <br /> 4 <br /> R602.3 Design and Construction <br /> Exterior walls of wood-frame construction shall be designed and constructed in accordance with the provisions of this chapter and Figures R602.3(1)and R602.3(2),or in accordance with <br /> AWC NDS.Components of exterior walls shall be fastened in accordance with Tables R602.3(1)through R602.3(4).Wall sheathing shall be fastened directly to framing members and,where <br /> placed on the exterior side of an exterior wall,shall be capable of resisting the wind pressures listed in Table R301.2(2)adjusted for height and exposure using Table R301.2(3)and shall <br /> conform to the requirements of Table R602.3(3).Wall sheathing used only for exterior wall covering purposes shall comply with Section R703. <br /> Studs shall be continuous from support at the sole plate to a support at the top plate to resist loads perpendicular to the wall.The support shall be a foundation or floor,ceiling or roof <br /> diaphragm or shall be designed in accordance with accepted engineering practice. <br /> Exception:Jack studs,trimmer studs and cripple studs at openings in walls that comply with Tables R602.7(1)and R602.7(2). <br /> TABLE R602.3(1) <br /> FASTENING SCHEDULE <br /> ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE SPACING AND LOCATION <br /> OF FASTENERa,b,c <br /> Roof <br /> 4-8d box(21/2"x 0.113")or <br /> 3-8d common(21/2'x 0.131");or <br /> 1 Blocking between ceiling joists or rafters to top plate Toe nail <br /> 3 10d box(3"x 0.128");or <br /> 3-3"x 0.131"nails <br /> 4-8d box(21/2"x 0.113");or <br /> 3-8d common(21/2'x 0.131");or <br /> 2 Ceiling joists to top plate 3 10d box(3"x 0.128") or <br /> Per joist,toe nail <br /> 3-3"x 0.131"nails <br /> 3 Ceiling joist not attached to parallel rafter,laps over 4-10d box(3"x 0.128");or Face nail <br /> partitions(see Section R802.5.2 and Table R802.5.2) 3-16d common(31/2"x 0.162");or 4-3"x 0.131"nails <br /> 4 Ceiling joist attached to parallel rafter(heel joint) Table R802.5.2 Face nail <br /> (see Section R802.5.2 and Table R802.5.2) <br /> 4-10d box(3"x 0.128");or <br /> Collar tie to rafter,face nail or 11/4'x 20 ga.ridge strap to <br /> 5 3 10d common(3"x 0.148");or Face nail each rafter <br /> rafter <br /> 4-3"x 0.131"nails <br /> 3-16d box nails(31/2"x 0.135");or <br /> 3-10d common nails(3"x 0.148");or 2 toe nails on one side and 1 toe nail <br /> 6 Rafter or roof truss to plate 4-10d box(3"x 0.128");or on opposite side of each rafter or truss' <br /> 4-3"x 0.131"nails <br />
The URL can be used to link to this page
Your browser does not support the video tag.