My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7718 CASCADE DR 2023 Plans 2024-06-11
>
Address Records
>
CASCADE DR
>
7718
>
Plans
>
7718 CASCADE DR 2023 Plans 2024-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 1:58:12 PM
Creation date
10/27/2023 11:18:11 AM
Metadata
Fields
Template:
Address Document
Street Name
CASCADE DR
Street Number
7718
Permit
B2309-030
Year
2023
Notes
REMODEL, KITCHEN ELEVATION CHANGE, REBUILD WALLS, PAINT, ETC.
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
b.Staples are 16 gage wire and have a minimum 7/16-inch on diameter crown width. <br /> c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater. <br /> d. Four-foot by 8-foot or 4-foot by 9-foot panels shall be applied vertically. <br /> e.Spacing of fasteners not included in this table shall be based on Table R602.3(2). <br /> f. For wood structural panel roof sheathing attached to gable end roof framing and to intermediate supports within 48 inches of roof edges and ridges, nails shall <br /> be spaced at 6 inches on center where the ultimate design wind speed is less than 130 mph and shall be spaced 4 inches on center where the ultimate design <br /> wind speed is 130 mph or greater but less than 140 mph. <br /> g.Gypsum sheathing shall conform to ASTM C1396 and shall be installed in accordance with GA 253. Fiberboard sheathing shall conform to ASTM C208. <br /> h.Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required blocking and at floor perimeters only. <br /> Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and required blocking. Blocking of roof or floor <br /> sheathing panel edges perpendicular to the framing members need not be provided except as required by other provisions of this code. Floor perimeter shall <br /> be supported by framing members or solid blocking. <br /> i.Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule, provide two toe nails on one side of the rafter and toe nails from <br /> the ceiling joist to top plate in accordance with this schedule.The toe nail on the opposite side of the rafter shall not be required. <br /> j. RSRS-01 is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667. <br /> TABLE R602.3(2) <br /> ALTERNATE ATTACHMENTS TO TABLE R602.3(1) <br /> SPACING`OF FASTENERS <br /> NOMINAL MATERIAL THICKNESS DESCRIPTIONa'b OF FASTENER AND LENGTH <br /> (inches) (inches) Edges intermediate supports <br /> (inches) (inches) <br /> Wood structural panels subfloor,roofs and wall sheathing to framing and particleboard wall sheathing to framing <br />
The URL can be used to link to this page
Your browser does not support the video tag.