Permit
B2302-115
Year
2023
Notes
DADU - NEW CONSTRUCTION 880 SQ FT DADU LOCATED NEAR REAR OF LOT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WOOD FRAMING: <br /> CIENER,4L. DF/L "2 4x/ 6x SEAMS, HEADERS, POSTS <br /> THE CONTRACTOR SHALL INSPECT THE SITE AND SOIL HF "2 EXTERIOR AND BEARING STUDS, PLATES, JOISTS, <br /> CONDITIONS AND VERIFY SITE AND BUILDING DIMENSIONS RAFTERS AND LIGHT FRAMING. <br /> BEFORE COMMENCING WORK. HF STD. NON-BEARING, INTERIOR STUDS, PLATES. <br /> PROVIDE TEMPORARY BRACING AS REQUIRED DURING <br /> ERECTION. C1LUED LAMINATED MEME3ERS= <br /> VERIFY SIZE AND LOCATION OP ALL OPENINGS IN FLOOR , ROOF <br /> AND WALLS WITH MECHANICAL AND ELECTRICAL WORK_ GLU-LAM MEMBERS SHALL SE A.I.T.G. CERTIFIED. <br /> PREFABRICATED ITEMS SHALL BE HANDLED AND INSTALLED DF/DF-24F-V4 OR SIMPLE SPAN BEAMS. <br /> PER MANUFACTURER'S RECOMMENDATION. DF/DF 24F-VS FOR CANTILEVERED BEAMS AND CONTINUOUS <br /> SPANS WHERE NOTED ON THE PLANS. <br /> FOUNDATIONS: APPLY ONE COAT OF END SEALER IMMEDIATELY AFTER <br /> TRIMMING <br /> 1. EXTEND ALL FOOTINGS DOWN TO FIRM UNDISTURBED SOIL IS <br /> INCHES BELOW ADJACENT GRADE. ENGINEERED LUM3ER: <br /> 2. CENTER FOOTINGS ON COLUMNS AND WALLS EXCEPT WHEN <br /> DIMENSIONED OTHERWISE. LSL TO BE 1.55E UNO <br /> 3. WIDEN FOUNDATION AND FOOTINGS 4 INCHES TO SUPPORT LVL TO BE 1.8E OR BETTER UNO <br /> MASONRY VENEER WHERE APPLICABLE. VERIFY LOCATIONS. PSL TO BE 2.OE OR SETTER UNO <br /> CONCRETE: SHEATINC : <br /> 1. CONCRETE DESIGN BASED ON 2500 PSI NO SPECIAL ROOF AND WALL SHEATHING SHALL BE 1/16" APA RATED <br /> INSPECTION REQUIRED. SUPPLIED CONCRETE TO BE SHALL BE SHEATHING UNO. NAIL WITH ad 6" O. C. 'a EDGES, 12" O. C. e <br /> 5.5 SACK MIX, 3000 PSI AT 25 DAYS UNO. TO BE AIR-ENTRAINED FIELD. FLOOR SHEATHING SHALL SE 3/4" NOMINAL TEG APA <br /> (5% - 1%) 3000 PSI AT 25 DAYS WHERE EXPOSED TO WEATHER RATED SHEATHING GLUED AND NAILED WITH 8d m 6" O. C. <br /> FOR DURABILITY. EDGES, 12" O. C. AT FIELD. SUPPORT PANEL EDGES PER APA <br /> 2. SLAB ON GRADE (HEATED SPACES) 4" CONCRETE SLAB WITH RECOMMENDATIONS. <br /> 1.4 6x6 W. W. MESH. 1" SAND OVER 6 MIL VAPOR BARRIER OVER <br /> 4" COARSE GRADE GRAVEL FILL. R-I0 x 24" RIGID INSULATION FDR.EFA5RICATED JOISTS / TRUSSES: <br /> AT PERIMETER WHERE SLAB IS LESS THAN 2' BELOW GRADE. PREFAB JOISTS AND TRUSSES SHALL BE DESIGNED BY THE <br /> MANUFACTURER. ENGINEERED SHOP DRAWINGS AND LAYOUT <br /> STEEL: SHALL BE SUBMITTED FOR APPROVAL. BRACING AND <br /> I. REINFORCING STEEL SHALL BE 4*4, GRADE 40. ALL BARS SHALL CONNECTIONS SHALL BE DESIGNED AND DETAILED BY THE <br /> SE CLEAN, DRY AND TIED IN PLACE. LAP SPLICES 15 INCHES MANUFACTURER. <br /> MINIMUM. <br /> 2. ANCHOR BOLTS SHALL SE 1/2" DIA. x 10" WITH 0.229" X 3" X 3" TRUSS LOADING SHALL TAKE LIVE LOADING SPECIFIED IN TABLE <br /> SQUARE PLATE WASHERS. SPACE AT 12" MAXIMUM AND 1 BOLT R30I.5 INTO ACCOUNT FOR BOTTOM CHORD LIVE LOADING OF 20 <br /> DIAMETERS MINIMUM FROM CORNERS, SPLICES AND PLATE ENDS. PSF. IF TRUSSES ARE DESIGNED FOR ATTICS WITHOUT STORAGE, <br /> SPACE ANCHOR BOLTS AT 6 FEET 0. C. FOR SINGLE STORY AND OR DO NOT MEET THE LIMITED STORAGE REQUIREMENTS, THE <br /> 4 FEET O. C. FOR TWO STORY. SEE SHEAR SCHEDULE FOR BOTTOM CHORD CAN BE DESIGNED FOR 10 PSF. <br /> SPACING AT SHEAR WALLS. ANCHOR BOLTS SHALL HAVE 1" <br /> MINIMUM EMBEDMENT. i" THREADED ROD, EPDXIED A MINIMUM OF HANGERS/FASTENERS: <br /> 4" INTO CONCRETE, OR " STRONG BOLT WITH 4" EMBEDMENT CAN ALL HANGERS AND FRAMING ANCHORS ARE TO BE SIMPSON OR <br /> BE SUBSTITUTED FOR CAST IN PLACE ANCHOR BOLTS EQUAL. ALL ML_TAL IN CONTACT WITH PRESSURE TREATED WOOD <br /> 3. STRUCTURAL STEEL PLATE IS TO BE A36 UNO AND FOR SEAMS ARE TO SE ZMAX, HDG(G185), STAINLESS STEEL, OR MEET ASTM A <br /> IS TO BE A992-50 UNO 13 OR A 653 STANDARDS. REFER TO IRC R311.3.1 OR IBC A <br /> 2304.9.5.1. JJJ <br />