Laserfiche WebLink
The comments below were generated from this project's City of Everett Civil Reviewers. All questions shall be routed through this project's Public Works <br />Reviewer Abiy Tsegaye with City of Everett Permit Services (ATsegave@everettwa.gov). <br /># <br />Document <br />Sht/Pg <br />Reviewer's Comment <br />Designer's Response <br />Initials <br />1 <br />Civil Plans <br />D1.01 <br />Ends of existing water main under new building to be capped <br />per COE DCSS 5-4. <br />EXIST/DEMO <br />(10 of 85) <br />2 <br />Civil Plans <br />D1.02 <br />Include Standard TESC Notes available in DCSS Volume I, <br />Section 2-5. Label corresponding BMP numbers/or COE <br />TESC PLAN <br />Standard dwg# for Inlet protections, Silt fence and all other <br />(11 of 85) <br />BMPS. <br />South East corner of new building shows demolition of existing <br />concrete pavement but the BMP/Silt fence doesn't include that <br />area. Please revise BMP. <br />3 <br />Civil Plans <br />C1.01 <br />Concrete sidewalk connecting to ADA ramp north of the new <br />building is shown as HMA path instead of permanent concrete <br />SITE PLAN <br />sidewalk. Please clarify why HMA is used or revise to <br />(14 of 85) <br />concrete. Clarify <br />4 <br />Civil Plans <br />C3.01 <br />Include required standard drainage notes available in DCSS <br />Volume I, Section 4-2.7. <br />UTILITY <br />PLAN/STORM <br />(19 of 85) <br />5 <br />Civil Plans <br />C3.01 <br />Include required standard water notes available in DCSS <br />Volume I, Section 5-2.1. <br />UTI LITY <br />PLAN/WATER <br />Water meters to be moved to ROW line (EMC 14.16.190). <br />(19 of 85) <br />Three 1" meters are shown on the plans. Please clarify the use <br />of the meters. <br />Please note on the plans." New water connections to be <br />performed by COE Water Dept Crews under separate Utility <br />permit based on a cost estimate prepared by the Water Dept <br />and paid for by the owner/contractor." <br />Page 2 of 5 <br />