HVAC
<br />GENERAL
<br />NOTES
<br />DUCT
<br />NOTES
<br />1.
<br />VERIFY SITE CONDITIONS.
<br />1.
<br />DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE
<br />2.
<br />THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT/GC.
<br />2018 SMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT, EXCEPT AS
<br />3.
<br />CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES.
<br />NOTED.
<br />4.
<br />COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH
<br />2.
<br />BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF
<br />ARCHITECT APPROVAL. VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION.
<br />DIFFUSERS.
<br />5.
<br />DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERY
<br />3.
<br />DUCT INSULATION: DUCTS, SHAFTS AND PLENUMS SHALL BE INSULATED TO MINIMUM
<br />OFFSET WHICH MAY BE REQUIRED.
<br />OF R-8 AND IN ACCORDANCE WITH THE SECTION C403.2.8 OF 2018 SEC.
<br />6.
<br />SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE
<br />4.
<br />DUCT SEALING —GENERAL: 0 TO 2" STATIC PRESSURE — SEAL ALL TRANSVERSE
<br />STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT".
<br />JOINTS AND LONGITUDINAL SEAMS ON ALL DUCTS, ABOVE 2"—SEAL SEAMS, JOINTS
<br />7.
<br />EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY LINE OR
<br />AND WALL PENETRATIONS. INSIDE BUILD: DURODYNE "DDS-181" GRAY OR
<br />OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS, OR DISTANCE AS REQUIRED
<br />APPROVED EQUAL PER ILL 181 A—M, 1818—M USTED. OUTSIDE: POLYURETHANE,
<br />PER LOCAL CODE.
<br />MAMECO VULKEM 116. OR APPROVED EQUAL.
<br />8.
<br />TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING,
<br />5.
<br />TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR
<br />INCLUDING WRITTEN REPORTS TO BE PROVIDED TO OWNER. BALANCE TO WITHIN 10% OF DESIGN.
<br />SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4
<br />9.
<br />OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS
<br />DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER
<br />ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE INSTRUCTIONS, AND MARKED UP AS —BUILT
<br />SMACNA STANDARD.
<br />DRAWING.
<br />6.
<br />FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS
<br />10.
<br />COMMISSIONING: PRIOR TO PASSING THE FINAL INSPECTION OR OBTAINING A CERTIFICATE OF
<br />NOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH
<br />OCCUPANCY, PROVIDE THE EVIDENCE OF SYSTEM COMMISSIONING AND COMPLETION IN ACCORDANCE
<br />FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL
<br />WITH THE PROVISIONS OF SECTION C408 OF THE 2018 SEC
<br />WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS & SCREWS ALLOWED.
<br />11.
<br />WALK—THRU INSTRUCTION: PROVIDE ON SITE WALK—THRU FOR CUSTOMER TO DEMONSTRATE
<br />7,
<br />SOUND LINER: PROVIDE SOUND UNED METAL SUPPLY & RETURN DUCTS AS SHOWN
<br />OPERATION OF SYSTEM AND ANSWER QUESTIONS.
<br />ON PLANS. MANVILLE PERMACOTE LINACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH
<br />12.
<br />ROOF TOP UNITS ON CURB: SEAL HOLES AND CRACKS BETWEEN DUCT AND ROOF DECK INSIDE
<br />ACRYLIC SURFACE TREATMENT OR EQUAL. FABRICATE AND INSTALL PER DUCT LINER
<br />FACTORY ROOF CURB FOR NOISE CONTROL.
<br />STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC.
<br />13.
<br />GAS PIPE: SCHEDULE 40, BLACK STEEL. PAINT PIPE EXPOSED TO WEATHER.
<br />OUTSIDE AIR DUCT IS NOT INSULATED THROUGH UNCONDITIONED AREA.
<br />14.
<br />SIZES: ALL PIPE SIZES SHOWN ARE MINIMUM.
<br />8.
<br />FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK—UPS TO ISOLATE AIR HANDLING
<br />15.
<br />PIPE HANGERS: SWIVEL LOOP STYLE, MICHIGAN NO.100 OR CLEVIS STYLE, NO.400 OR EQUAL
<br />EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE)
<br />BRAND, WITH ALTHERED STEEL ROD SIZED PER INDUSTRY STANDARDS.
<br />9,
<br />DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR
<br />16.
<br />ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN
<br />RECTANGULAR DUCTS THAT ARE NOT LINED. PROVIDE CIRCULAR EQUIVALENT OF
<br />SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF
<br />RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE
<br />EQUIPMENT FOR SERVICE & MAINTENANCE PURPOSES (2018 SMC SECTION 301.10). LINE VOLTAGE
<br />SUBSTITUTED TO BETTER FIT SPACE.
<br />WORK BY OTHERS.
<br />10.
<br />TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO
<br />17.
<br />SUSPENDED MECHANICAL EQUIPMENT AND APPLIANCES SHALL HAVE RIGID VERTICAL HANGERS AND
<br />KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL
<br />BE BRACED IN BOTH HORIZONTAL DIRECTIONS.
<br />OPENINGS.
<br />DIFFUSERS/CLILLS SCHEDULE
<br />TAG
<br />NUMBER
<br />MAKE
<br />MODEL
<br />SIZE
<br />NOTE
<br />SD-1
<br />3
<br />SHOEMAKER
<br />700MA
<br />24X24
<br />1
<br />RG-1
<br />2
<br />SHOEMAKER
<br />EGGCRATE
<br />24X24
<br />-
<br />NOTES:
<br />1. NECK COLLAR SIZES PER PRINT
<br />LEGAL DESCRIPTION:
<br />Section 18 Township 29 Range 05 Quarter SE LOT A14 OF BSP
<br />FOR DIV 3 OF PORT OF EV N MARINA BSP16-004 REC UND AFN
<br />201708075002& AS CORR BY AFN 201812265002 BEING A PEN OF
<br />SE1/4 SD SEC EX BLDG (HOTEUNDIGO) ON 29051800402401
<br />TAX PARCEL NUMBER: 29051800402400
<br />VICINITY MAP
<br />(15 NTS
<br />AREA OF WORK
<br />FREEDOM BOAT CLUB AREA OF WORK
<br />15 NTS
<br />DRAWING INDEX
<br />M-1
<br />LEGEND &
<br />ABBREVIATIONS,
<br />VICINITY MAP,
<br />NOTES,
<br />EQUIPMENT SCHEDULE
<br />M-2
<br />NEW HVAC
<br />PLAN
<br />LEGEND & ABBREVIATIONS
<br />SYMBOL
<br />ABBREV.
<br />DESCRIPTION
<br />SYMBOL
<br />ABBREV. DESCRIPTION
<br />® ®
<br />SUPPLY DUCT
<br />♦
<br />FIRE DAMPERED DUCT
<br />0 z
<br />RETURN/EXHAUST DUCT
<br />PENETRATION OF A
<br />HORIZONTAL SEPARATION
<br />SL
<br />SOUNDLINED DUCT
<br />�y
<br />FlRE DAMPERED DUCT
<br />sus
<br />VD
<br />MANUAL VOLUME DAMPER
<br />PENETRATION OF A
<br />FC
<br />FLEX CONNECTOR
<br />VERTICAL SEPARATION
<br />h
<br />TV
<br />TURNING VANES
<br />o
<br />TIMER 0-4 HR ADJUSTABLE
<br />EC
<br />END CAP
<br />O
<br />THERMOSTAT/HVAC UNIT #
<br />®
<br />SO
<br />SUPPLY DIFFUSER, CEILING
<br />O
<br />SENSOR/HVAC UNIT #
<br />®
<br />MG
<br />MAKEUP GRILLE
<br />OO
<br />SENSOR (CEILING MOUNT)
<br />z
<br />RG
<br />RETURN GRILLE, CEILING
<br />O
<br />EXHAUST FAN
<br />z
<br />EG
<br />EXHAUST GRILLE, CEILING
<br />—0-0
<br />PIPE/DUCT UP
<br />z
<br />TG
<br />TRANSFER GRILLE, CEILING
<br />PIPE/DUCT DOWN
<br />—1 --
<br />SIDEWALL SUPPLY/MAKEUP
<br />PIPE TEE DOWN
<br />SIDEWALL RETURN/EXHAUST
<br />PIPE TEE UP
<br />ll -_271
<br />EQUIPMENT TAG
<br />EXIST DUCTWORK, EQUIP
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />NEW DUCTWORK, EQUIP
<br />BD, BDD
<br />BACKDRAFT DAMPER
<br />CEILING RADIATION DAMPER
<br />VALVE
<br />BS
<br />BIRDSCREEN
<br />BALANCING VALVE
<br />ON
<br />DOWN
<br />EA
<br />EXHAUST AIR
<br />ADJ
<br />ADJACENT
<br />OA, OSA
<br />OUTSIDE AIR
<br />BSC
<br />BIOLOGICAL SAFETY CABINET
<br />RA
<br />RETURN AIR
<br />CFH
<br />CHEMICAL FUME HOOD
<br />SA
<br />SUPPLY AIR
<br />CFM
<br />CUBIC FEET PER MINUTE
<br />(N)
<br />NEW
<br />DB
<br />DUCT BOARD
<br />(E)/EXIST
<br />EXISTING
<br />L,S
<br />LIQUID, SUCTION
<br />(R)
<br />RELOCATED
<br />N
<br />NECK
<br />BWG
<br />BOTTOM WALL GRILLE
<br />NIC
<br />NOT IN CONTRACT
<br />TWG
<br />TOP WALL GRILLE
<br />CAI
<br />OUTSIDE AIR INTAKE
<br />TYR
<br />TYPICAL
<br />RD
<br />ROUND DIFFUSER
<br />VD
<br />VOLUME DAMPER
<br />SHC
<br />SENSIBLE HEATING CAPACITY
<br />DEMO
<br />SR
<br />SUPPLY REGISTER
<br />TC
<br />TOTAL COOLING
<br />REVISIONS
<br />VEL
<br />VELOCITY
<br />WH
<br />WATER HEATER
<br />SC
<br />SOUND CAN
<br />AIR
<br />TERMINAL
<br />LEGEND
<br />GRILLE, REGISTER, XX 8X8NECK SIZE (INCHES)
<br />DIFFUSER IN LEGEND 140 SQUARE OR RECTANGULAR
<br />AIR QUANTITY (CFM)
<br />XX 8"0 NECK SIZE (INCHES)
<br />140 ROUND
<br />Air Quantity (CFM)
<br />ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS
<br />NO ARROWS INDICATE FOUR WAY PATTERN
<br />FIRE SPRINKLER HEADS TO BE FAST REACTION TYPE BY OTHERS.
<br />DESCRIPTION OF WORK:
<br />�rlmJW,LNI:Lrai!un,fyynn�nn,�rar,K �nal�
<br />2. INSTALL TWO (3) DIFFUSERS AND (3) GRILLES
<br />3. AIR BALANCE
<br />U
<br />W
<br />0
<br />o-
<br />o_
<br />0
<br />w
<br />0
<br />0
<br />d
<br />0
<br />0'
<br />a
<br />M
<br />Z
<br />a {
<br />O N
<br />O 00
<br />J O
<br />Q
<br />H
<br />LU
<br />J_ W
<br />LU
<br />O
<br />N
<br />a)
<br />Wl
<br />of 2