Laserfiche WebLink
----- SM SOLAR CODE COMPLIANCE NOTES C <br />■■ MOUNT ---------------------------------------------------------------- INSTALLATION GUIDE-'I- P A G E <br />SYSTEM LEVEL FIRE CLASSIFICAMN <br />The system fire class rating requires installation in the manner specified in the SOLARMOUNT Installation Guide. SOLARMOUNT has been classified to the system <br />Level fire portion of UL2703. SOLARMOUNT has achieved system level performance for steep sloped roofs. The fire classification rating is only valid on roof pitches <br />greater than 2:12 (slopes i 2 inches per foot, or 9.5 degrees). The system is to be mounted over fire resistant roof covering rated for the application. There is no <br />required minimum or maximum height limitation above the roof deck to maintain the system fire rating for SOLARMOUNT. Module Types, System Level Fire Ratings, <br />and Mitigation Requirements are listed below: <br />Light Rail <br />1 & 2 <br />Class A, Class B & Class C <br />East-West <br />Landscape OR Portrait <br />None Required <br />North -South <br />Landscape OR Portrait <br />None Required <br />Standard, Light, & <br />HD Rails <br />4 & 5 <br />I Class A, Class B & Class C <br />East-West <br />Landscape OR Portrait <br />Trim installation per Solar <br />Mount Installation Guide <br />North -South <br />Landscape OR Portrait <br />This racking system may be used to ground and/or mount a PV module complying with UL1703 or UL61730 only when the specific module has been evaluated for <br />grounding and/or mounting in compliance with the included instructions. <br />UNIRAC <br />U12 70 3 CIIZT MATION NIARK NG LABEL <br />Unirac SOLARMOUNT is listed to UL 2703. Certification marking is embossed on all mid clamps as shown. Labels with <br />additional information will be provided .After the racking system is fully assembled, a single label should be applied to the <br />SOLARMOUNT rail at the edge of the array. Before applying the label, the corners of the label that do not pertain to the co, <br />system being installed must be removed so that only the installed system type is showing. C US <br />Note: The sticker label should be placed such that it is visible, but not outward facing. 266909 <br />SM STANDARD RAIL <br />�GNIRAC <br />�� xeeluxwccor:wnrn I/IANN TiY� <br />1"1 n. f — 1.Ily 1.. rwNw. 7raw.... h <br />0�1�%V�Mt..lr...wN I. Ylr•. 1M 61 h. CUr11.Iwr �. <br />iM/ 1.YM ... IwNN.Nw 1.Nrw Mw <br />y. A.11� Mw tV. w.r.1 <br />SM LIGHT RAIL <br />• • • NIRAC \ <br />wnanti-a .vane rlox MIYY" <br />1". M (W. 5N 4 tw 1..6.8~ A <br />MwNs�►�... 1..►.r..tr 1. A.%— 6MAW pl.. 0... <br />r..T 1..11Nw! 1.. Iw1No... t..►w w.. <br />� rY O.rr I.rr 4.r W.a w 1na�..IW.In O.N/.. <br />�\r. rr wow rw wwi <br />*1� <br />BLUE RAVEN <br />1403 N. Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W.BLUERAVENSOLAR.COM <br />CONFIDENTIAL- THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NABCEP <br />CERTIFIED <br />PV INSTALLATION <br />PROFESSIONAL <br />Scott Gurney <br />#PV-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OPS <br />385-498-6700 <br />DRAWING BY: <br />PLOT DATE: <br />PROJECT NUMBER: <br />SPEC SHEET <br />REVISION: I PAGE NUMBER: <br />SS <br />