Laserfiche WebLink
MASTER CONTRACT: 266909 <br />REPORT: 70131735 <br />PROJECT: 80136577 <br />SM and ULA markings <br />The following markings appear on the rail by adhesive label: <br />Page No: 6 <br />Date Issued: August 12, 2022 <br />1. Submitter's name and/or CSA Master Contract number "266909"; <br />2. Model designation; <br />3. Manufacturing date; <br />4. System fire class rating/designation of information location in Installation Manual; <br />5. Design load rating/designation of information location in Installation Manual; <br />The following markings appear on the Mid clamp by stamping: <br />1. Submitter's name and/or CSA Master Contract number "266909"; <br />2. CSA mark <br />3. Mil ID for factory location <br />Nameplate adhesive label material approval information: <br />SATO AMERICA INC, SF401 DuraMark Polyester, MH48415 - Printing Materials — Component, UL 969- <br />Marking and Labeling Systems <br />RM 5 South and RM DT markings <br />The following markings appear on the ballast bay by permanent stamping: <br />1. Submitter's name and/or CSA Master Contract number "266909"; <br />2. Model designation; <br />3. Manufacturing date; <br />4. System fire class rating/designation of information location in Installation Manual; <br />5. Design load rating/designation of information location in Installation Manual; <br />UNIRAC RM SOUTH 5 <br />CONFORMS TO UL STD 2703 <br />PATENT PENDING <br />UNIRAC MFR DDDYY <br />coal <br />us <br />266909 <br />SYSTEM FIRE CLASS RATING: SEE INSTALLATION INSTRUCTIONS FOR INSTALLATION AEQ U I R L M E N TS TO ACIII EVE A <br />SPECK ILO -I EM Ift 1-1 WIIING WIIN -, RRVUVC F. <br />DE51GN LOAD RATING: SCE INSTALLATION INSTRUCTIONS FOR LOADS AND MOW LES QUALIFIED FOR USE WITH TNIS <br />RR 111 <br />Nameplate adhesive label material approval information: <br />Markings applied via permanent stamping to bay. <br />DQD 507.10 Rev 2022-08-05 <br />C <br />1/IlIIC Ml�IS <br />C IU18 <br />000ra� <br />�.Ewo <br />low C00YY <br />© 2022 CSA Group. All rights reserved. <br />MASTER CONTRACT: 266909 <br />REPORT: 70131735 <br />PROJECT: 80136577 <br />Page No: 9 <br />Date Issued: August 12, 2022 <br />1. The system does not employ a maximum number of modules that can be installed per system. <br />2. Module Orientation: <br />a. SM & ULA - Portrait or Landscape <br />b. RM5 & DT — Landscape <br />a. GFT — Portrait <br />d. NXT Horizon - Portrait or Landscape <br />3. The system was evaluated for use with modules up to: <br />a. SM & ULA — 27.12 sq ft <br />b. RM5 & DT — 27.76 sq ft <br />c. GFT - Portrait - 27.12 sq ft <br />d. NXT Horizon —27.76 sq ft <br />4. See Table 1 for customer supplied information for SM <br />5. See Table 2 for customer supplied information for ULA <br />6. See Table 3 for customer supplied information for RM <br />7. See Table 4 for customer supplied information for GFT <br />8. See Table 5 for customer supplied information for NXT Horizon <br />9. See the attached installation manual for each model installation instructions, and system drawings. <br />The critical components identified below may be formed at other locations and shipped directly <br />to the construction site provided they are made with the material/coatings identified and conform <br />to the physical dimensions described and shown in their respective illustrations. Physical <br />specimens may not be present at the location where the CSA mark is applied. Location of <br />markings can be found in the Marking section of this report. <br />Table I <br />MODULE RACKING SYSTEM TYPE/S <br />Model <br />SM <br />Module Fire Type .............................: <br />Class A with Type 1, 2, 3 (with metallic frame), 4 (with trim), <br />5 (with trim), 10 (with metallic frame), 19, 22, 25, 29, or 30 for <br />steep slope. Tested at 5" interstitial gap, the rating obtained for a <br />5-inch (127 mm) gap can be used for any other gaps allowed by <br />the mounting instructions, per section 15 of UL 2703 <br />Max branch circuit overcurrent- <br />30 <br />protection device (A) <br />IDENTIFICATION OF COMPONENTS <br />AND MATERIALS <br />End Clamp ........................................: <br />M 101 XX Rev. H <br />Extruded Aluminum: 6005A-T61, 6351-T5, 6061-T6, 6005-T5, <br />6105-T5 <br />End Clamp Assembly .......................: <br />M50OXX Rev. C, (M50060 — M50071) <br />Extruded Aluminum: 6005A-T61, 6351-T5, 6061-T6, 6005-T5, <br />6105-T5 <br />Bonding Mid Clamp .........................: <br />M6065X, Rev A and M6065X, Rev F <br />300 Series Stainless Steel <br />DQD 507.10 Rev 2022-08-05 <br />© 2022 CSA Group. All rights reserved. <br />BLUE RAVEN <br />1403 N. Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W. BLU ERAVENSOLAR.COM <br />CONFIDENTIAL -THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NABCEP <br />CERTIFIED <br />PV INSTALLATION <br />PROFESSIONAL <br />Scott Gurney <br />#PV-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OPS <br />385-498-6700 <br />DRAWING BY: <br />PLOT DATE: <br />PROJECT NUMBER: <br />SPEC SHEET <br />REVISION: I PAGE NUMBER: <br />SS <br />