My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7021 LOWER RIDGE RD 2023-11-28
>
Address Records
>
LOWER RIDGE RD
>
7021
>
7021 LOWER RIDGE RD 2023-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2023 11:14:54 AM
Creation date
11/2/2023 8:11:28 AM
Metadata
Fields
Template:
Address Document
Street Name
LOWER RIDGE RD
Street Number
7021
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A B I C D E I F G I H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> • 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> ,1r . � ,.•R „„-,5„ . ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> _ THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> �'��` ,t •j`! 4` 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH <br /> BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. <br /> �. �`+ • (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> �.' 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> �. r r LABORATORY SHALL LIST ALL OF WORK. <br /> til EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> ti ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> CN f ; r y 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> `� p ry ~ .�- �� • . 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING <br /> (� � AT THE UL-LISTED LOCATION PROVIDED INVERTER. <br /> s BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF <br /> UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. <br /> 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> 1, GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> r ” 7. THE DC GROUNDING ELECTRODE <br /> co SPECIFICATIONS. L, <br /> CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH <br /> RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> 690.47. (IBC) <br /> 9. ALL ELECTRICAL WORK TO BE IN <br /> VOR Jp COMPLIANCE WITH THE NATIONAL <br /> WASH N %V ELECTRIC CODE (NEC). <br /> CO 2 <br /> a 201148 8 Q� <br /> FS,RFGIs G\� <br /> SIpNALEN <br /> 8/24/2023 <br /> STRUCTURAL ONLY SHEET INDEX <br /> PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> LoPV 2 SITE PLAN PV 6 PLACARD Ul <br /> PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> PV 4 CHIKO MOUNTING <br /> DRAWN BY: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Robert Dixon EAC DESIGN <br /> DATE: <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> SO L G E N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5715 BEDFORD ST, 23/08/2023 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 7021 Lower Ridge Rd Everett WA 98203 PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 1 <br /> CONSENT FROM SOLGEN POWER. <br />