My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
26 81ST ST SW 2023-11-28
>
Address Records
>
81ST ST SW
>
26
>
26 81ST ST SW 2023-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2023 11:26:17 AM
Creation date
11/2/2023 8:22:35 AM
Metadata
Fields
Template:
Address Document
Street Name
81ST ST SW
Street Number
26
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES AERIAL VIEW <br /> CODE AND STANDARDS - 1 ' <br /> . Nor <br /> 1.ALL WORK SHALL COMPLY WITH 2017 NATIONAL ELECTRIC CODE(NEC),2015 INTERNATIONAL BUILDING CODE y t�GY 3 a � i `.,+ BLUE RAVEN <br /> (IBC),2015 INTERNATIONAL RESIDENTIAL CODE(IRC),2015 INTERNATIONAL PLUMBING CODE(IPC),AND ALL STATE L'x5 C J U�7 5 <br /> AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. <br /> 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. <br /> 1403 N. Research Way <br /> : :: <br /> SITE NOTES/OSHA REGULATION R r t Ilk 1403 <br /> UT 84097 <br /> 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 800.377.4480 <br /> 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. _ + WWW.BLUERAVENSOLAR.COM <br /> 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. ,`� ;►7 <br /> 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND ;►^•r- ^ CONFIDENTIAL-THE INFORMATION <br /> THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT + HEREIN CONTAINED SHALL NOT BE <br /> THE BUILDING OR STRUCTURE. • -0k AdPhk USED FOR THE BENEFIT OF ANYONE <br /> EXCEPT BLUE RAVEN SOLAR NOR <br /> SHALL IT BE DISCLOSED IN WHOLE OR <br /> SOLAR CONTRACTOR ' �, IN PART TO OTHERS OUTSIDE <br /> k <br /> 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. • . .- � �'— r •:+j,`�� t RECIPIENTS ORGANIZATION,EXCEPT <br /> 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER f i , . -1 IN CONNECTION WITH THE SALE AND <br /> THE MANUFACTURER'S INSTALLATION REQUIREMENTS. -� USE OF THE RESPECTIVE EQUIPMENT, <br /> 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF WITHOUT THE WRITTEN PERMISSION <br /> OF BLUE RAVEN SOLAR LLC. <br /> STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. <br /> 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO r <br /> LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. — 'v r♦ . <br /> 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A NABC E P <br /> SUITABLE SEALING COMPOUND. <br /> 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. CERTIFIED] <br /> 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. ` ' �' . `'1E• <br /> 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT <br /> AVAILABLE. P PV INSTALLATION <br /> .� , + <br /> 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC f r r —+*1 PROFESSIONAL <br /> PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND Scott Gurney <br /> CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND `, y- f +*'# #PV-011719-015866 <br /> LISTED FOR THE APPLICATION PER NEC 690.4(B). T y �_ '` •r y�R ''`` w�- ; - * <br /> 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. •+ y' 4+�F :� <br /> 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) J � i_'r� �� t ° CONTRACTOR: <br /> BRS FIELD OPS <br /> IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. ., ry ,fi ,r _ -! ' - < •F;i ,i`�� <br /> 800-377-4480 <br /> EQUIPMENT LOCATIONS <br /> 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT <br /> WILL BE PROVIDED AS PER SECTION NEC 110.26. <br /> o ,7 , <br /> 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS <br /> SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). <br /> 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC ' <br /> APPLICABLE CODES. <br /> 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. <br /> 1•� O <br /> .4� a) M `e <br /> PROJECT INFORMATION: _ ' - ' z rn LID co <br /> N M <br /> NUMBER OF STORIES: 2 , ► � O UO O W W <br /> CONDUIT RUN: Interior i r LL :3 N N_ <br /> ECOBEE QTY: 0 z co <br /> LIGHT BULB QTY: 0 <br /> PV METER: Not RequiredDESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX 2 p aL�i H H <br /> ROOF TYPE (1) INFORMATION: O -0 U) 4— N <br /> WIND SPEED: 110 mph CONSTRUCTION -V-B PV1 -COVER SHEET L -1-1N N <br /> ROOF TYPE: Comp Shingle GROUND SNOW LOAD: 15 Ib/ft' ZONING: RESIDENTIAL PV2-SITE PLAN to o0o N <br /> FRAMING TYPE: Manufactured TrussWIND EXPOSURE FACTOR: C PV3- ROOF PLAN U cfl > U U <br /> SHEATHING TYPE: OSB V E N W Q ID <br /> ATTACHMENT: SFM Infinity Flashkit SEISMIC DESIGN CATEGORY: D PV4-STRUCTURAL <br /> RACKING: Unirac SFM Infinity @ 48 OC Portrait/72 OC Landscape PV5- ELECTRICAL CLINE DIAGRAM <br /> SCOPE OF WORK DRAWING BY: <br /> NUMBER OF ATTACHMENTS: 15 PV6- ELECTRICAL CALCULATIONS <br /> PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore <br /> ROOF TYPE (2) INFORMATION (IFAPPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY (ALL OTHER SHEETS AS REQUIRED) <br /> *SEE PV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. SS- PRODUCT SPEC. SHEETS PLOT DATE: <br /> September 29, 2023 <br /> PROJECT NUMBER: <br /> SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: 847836 <br /> DC SYSTEM SIZE: 3.36 kW DC Snohomish County Public Utilities District <br /> AC SYSTEM SIZE: 2.52 kW AC (PUD) SHEET NAME: <br /> MODULE TYPE: (8) REC Solar REC420AA PURE-R COVER SHEET <br /> INVERTER TYPE: Enphase IQ7X-96-2-US <br /> MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 PERMIT ISSUER: REVISION: PAGE NUMBER: <br /> City of Everett 0 PV 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.