STANDARD LABELS ADDITIONAL LABELS <br /> LABEL 1 LABEL 8 BLUE RAVEN <br /> WARNINGFOR PV SYSTEM DISCONNECTING MEANS WHERE THE ! WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE LABEL U20 <br /> LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE PLACARD TO BE LOCATED AT UTILITY METER. <br /> ELECTRIC SHOCK HAZARD OPEN POSITION. POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way <br /> (2017 NEC 690.13(6)] SUPPLIED FROM MAIN DISTRIBUTION SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 <br /> TERMINALS ON THE LINE AND (2020 NEC 690.13(6)] LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> LOAD SIDES MAY BE ENERGIZED UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER 800.377.4480 <br /> IN THE OPEN POSITION PRODUCTION SOURCES CAPABLE OF BEING WWW.BLUERAVENSOLAR.COM <br /> INTERCONNECTED. CONFIDENTIAL-THE INFORMATION <br /> [2017 NEC 705.10] HEREIN CONTAINED SHALL NOT BE <br /> [2020 NEC 705.10] USED FOR THE BENEFIT OF ANYONE <br /> LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR <br /> PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR <br /> THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE <br /> I AC DISCONNECT I AND WITH THE RATED AC OUTPUT CURRENT AND THE ! V1►ARN I N G PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT <br /> NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE IN CONNECTION WITH THE SALE AND <br /> (2017 NEC 690.54] POWER TO THIS BUILDING IS ALSO SUPPLIED DISCONNECTING MEANS ON OR IN THE PREMISES USE OF THE RESPECTIVE EQUIPMENT, <br /> RATED AC OUTPUT CURRENT 10.48 A 12020 NEC 690.54] WITHOUT THE WRITTEN PERMISSION <br /> FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. <br /> NOMINAL OPERATING AC VOLTAGE 240 V LOCATION AND AT THE LOCATION(S)OF THE SYSTEM <br /> ARRAY RAPID SHUTDOWN DISCONNECT IS DISCONNECT(S)FOR ALL ELECTRIC POWER <br /> LOCATED OUTSIDE NEXT TO THE UTILITY METER. PRODUCTION SOURCES CAPABLE OF BEING <br /> LABEL 3 INTERCONNECTED. NABCEP <br /> 0 WARNING IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL [2017 NEC 705.10] <br /> [2020 NEC 705.10] CERTIFIED] <br /> ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br /> DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL <br /> AND SUBPANELS. PV INSTALLATION <br /> (2017 NEC 705.12(B)(3)] LABEL 10 PROFESSIONAL <br /> SOURCES: UTILITY GRID AND (2020 NEC 705.12(6)(3)] <br /> L <br /> WARNING PERMANENT PLAQUE VDIRECTORY TO BE <br /> PV SOLAR ELECTRIC SYSTEM LOCATED AT MAIN SERVICE EQUIPMENT DENOTING Scott Gurney <br /> PHOTOVOLTAIC SYSTEM THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 <br /> DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br /> COMBINER PANEL SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: <br /> ID WARN I N G LABEL 4 GROUPED AND WITHIN LINE SITE OF MAIN BFIELD OPS <br /> APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT DO NOT ADD LOADS SERVICE DISCONNECTING MEANS. 800-377-4480 <br /> TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] 80 <br /> POWER SOURCE OUTPUT CONNECTION SOURCE. [2020 NEC 705.10 AND 690.56(C)] <br /> DO NOT RELOCATE 12017 NEC 705.12(B)(2)(3)(b)] <br /> (2020 NEC 705.12(6)(3)(2)] <br /> THIS OVERCURRENT LABEL 11 <br /> DEVICE PERMANENT PLAQUE OR DIRECTORY TO BE 0 U <br /> LOCATED AT AC COMBINER PANEL. Z Q <br /> (2017 NEC 110.21(8)] <br /> (2020 NEC 110.21(8)] 0 q <br /> SOLAR PV SYSTEM EQUIPPED o N Co <br /> Q L M <br /> WITH RAPID SHUTDOWN N <br /> TURN <br /> SWITCH TO THE V W I.LI <br /> "OFF"POSITION TOAQO <br /> SHUT DOWN PV SYSTEM PV LL O 'V N_ <br /> 4— <br /> ANDRE DUCE SUB PANE L <br /> Z � C (� (n <br /> SNOTHEA ,RD UTILITY MAIN (IF INTERCONNECTION AC METER PV COMBINER U) <br /> METER SERVICE PANEL IS MADE HERE) DISCONNECT (IF APPLICABLE) BOX L) 4- U) <br /> LU LU LU <br /> RAPID SHUTDOWNOO OO OO 11 0 -0V) 4- <br /> SWITCH • . LABEL 6 Co i <br /> BUILDINGS WITH PV SYSTEMS SHALL HAVE A U20 W L QD N N <br /> SOLARPERMANENT LABEL LOCATED AT EACH SERVICE O O O O O U (D > V V <br /> EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS V E N LU Q Q <br /> ARE CONNECTED OR AT AN APPROVED READILY <br /> VISIBLE LOCATION AND SHALL INDICATE THE LOCATION O IF BREAKER OR PLACARD <br /> WARNING OF RAPID SHUTDOWN INITIATION DEVICES. IS USED DRAWING BY: <br /> (2017 NEC 690.56(C)(1)(a)] <br /> MA INDISTRIBUTIONUTILITYDISCONNECT(S) [2020 NEC 690.56(C)] OR <br /> 10 Brendan Fillmore <br /> POWER TO THIS BUILDING IS ALSO SUPPLIED OR PLACARD PLOT DATE: <br /> FROM A ROOF MOUNTED SOLAR ARRAY WITH <br /> A RAPID SHUTDOWN DISCONNECTING MEANS LABEL? September 29, 223 <br /> GROUPED AND LABELED WITHIN LINE OF SITE SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br /> AND 10 FT OF THIS LOCATION SWITCH <br /> 12017 NEC 690.56(C)(3)] PROJECT NUMBER: <br /> 12020 NEC 690.56(C)(2)] <br /> 847836 <br /> LABELING NOTES SHEET NAME: <br /> 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS <br /> REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL <br /> 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED <br /> 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: <br /> 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 <br /> HANDWRITTEN[NEC 110.211 DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />