Laserfiche WebLink
N ROOF HVAC DEMO PLAN <br />1/8"=T-O" <br />RTU <br />EXIST <br />(E) <br />INSTALL (N) UNIT ON (E) CURB W/ CURB ADAPTER — — RECONNECT TO (E) BUILDING DUCTWORK AIR <br />\ DISTRIBUTION SYSTEM. RECONNECT TO (E) ELECTRICAL & <br />/ <br />\ CONTROLS SYSTEM. (N) DISCONNECT BY E.C. <br />/ RTU <br />\ <br />/ R-01 <br />IN <br />I <br />Ia <br />\ <br />1 <br />I <br />I <br />1 <br />I <br />/ <br />\ <br />10'-0" / <br />RTU <br />EXIST <br />/ <br />(E) <br />10'-0" OSA CLEARANCE. NO EXHAUST <br />OR VENTS WITHIN THIS AREA <br />N ROOF HVAC PLAN <br />1/8"=1'-0" <br />PACKAGE HEAT PUMP UNIT <br />LOCATION <br />MANUFACTURER <br />& MODEL No. <br />SERVING <br />MIN. <br />OSA <br />CFM <br />DCV <br />OSA <br />CFM <br />SUPPLY FAN <br />DX COOLING <br />HEATING <br />AUXn <br />HEATMERV <br />KW <br />FILTER <br />CFM <br />E.S.P. <br />(in w.a) <br />FRPMBHPHP <br />REF. <br />TYPE <br />TOTAL <br />MBH <br />SENS. <br />MBH <br />EDB/ <br />EWB <br />LDB/ <br />LWB <br />AMB <br />("F) <br />TOTAL <br />MBH <br />EDB <br />LDB <br />AMB <br />("F) <br />MCAMOCP <br />SCCRVOLTAGE <br />(KAI <br />EMERGENCY <br />POWER <br />COOLING <br />HEATING <br />VIB.TAG <br />ISO <br />UNIT <br />CURB <br />ECONO. <br />TOTALNOTES <br />SEER <br />EER <br />IEER <br />HSPF <br />COP7kYR-W <br />-RGOFx <br />- - - -"EXIST-x-x-x-x <br />x�iXF&fx <br />- <br />- - <br />- - <br />- - <br />- - <br />- <br />- - <br />- <br />- - <br />- - <br />- <br />- <br />- - <br />- <br />- <br />RTUi <br />ROOF <br />CARRIER 50GCQT05A2A3-OAOAO <br />- <br />- <br />- <br />1,600 <br />1.00 <br />2,014 <br />0.88 <br />- <br />R410A <br />49.4 <br />S7 <br />80/87 <br />59157 <br />95 <br />45.6 <br />70 <br />96 <br />47 <br />9.8N/A <br />98 <br />100 <br />- <br />208/1 <br />N <br />15 <br />- <br />- <br />7.1 <br />3.6 <br />N <br />610 <br />TBD <br />- <br />TBD <br />2 - 10 <br />NOTES: <br />1. DEMO EXISTING UNIT. <br />2. REPLACE EXISTING UNIT WITH NEW, LIKE FOR LIKE. <br />3. OSA CFM OF NEW UNIT TO MATCH OSA CFM OF DEMO'D UNIT. <br />4. CONNECT NEW UNIT TO EXISTING THERMOSTAT BY C.C. <br />5. RECONNECT TO EXISTING BUILDING DUCTWORK AIR DISTRIBUTION SYSTEMS. <br />6. RE -USE EXISTING ELECTRICAL DISCONNECT. WIRE DISCONNECT TO NEW UNIT BY E.C. <br />7. PROVIDE WITH 100% INTEGRATED ECONOMIZER PER 2018 WSEC/SEC 403.5 <br />8. UNIT COOLING CAPACITY IS GREATER THAN 42,000 BTU/H: PROVIDE UNIT WITH 2-SPEED FAN PER 2018 WSEC/SEC C403.8.5.1 <br />9. FACTORY -PROVIDED LOW -LEAK MOTORIZED DAMPERS ON OSA INTAKE AND RELIEF PER 2018 WSEC/SEC C403.7.8 <br />10. PROVIDE WITH (N) CURB ADAPTOR ATTATCHEMENT TO (E) CURB & UNIT ATTATCHMENT TO ADAPTOR PER STRUCTURAL PACKAGE <br />I en ineered <br />systems <br />5300 DENVER AVENUE SOUTH <br />SEATTLE, WASHINGTON 98108 <br />(206) 787-8500 <br />THE PLANS AND SPECIFICATIONS HEREIN <br />ARE OWNED BYAND FOR THE SOLE USE OF <br />ACCO ENGINEERED SYSTEMS, INC. (-ACCO-), <br />AND MAYNOT BE REPRODUCED OR USED <br />BY OTHERS FOR ANYPURPOSE UNLESS <br />AUTHORIZED BYACCO IN WRITING. ACCO <br />CANNOTACCEPTANYLIABILITY, WARRANTY, OR <br />OBLIGATION IN THE EVENT OF UNAUTHORIZED USE <br />AREA OF WORK <br />N <br />KEY PLAN <br />1 <br />08/31/2023 <br />ISSUE FOR REVIEW <br />TD <br />NO. <br />Date <br />Description <br />By <br />Revisions <br />Project <br />EVERETT MALL <br />UNIT REPLACEMENT <br />1203 SE EVERETT MALL WAY, STE #Q <br />EVERETT, WA. 98208 <br />Title <br />ROOF DEMO & HVAC PLANS, <br />& EQUIPMENT SCHEDULES <br />T.DALGLEISH T.TOUTONGHI <br />Designed By Checked By <br />T.DALGLEISH D.RISTOW <br />Drawn By Project Manager <br />70870665 AS SHOWN <br />Job Number Scale <br />M1.0R <br />