Laserfiche WebLink
EVERETT MALL <br />UNIT REPLACEMENT <br />SYMBOL LEGEND <br />HVAC <br />PIPING <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />(N)® Z(E) <br />NEW (N)aEXISTING (E) RECTANGULAR SUPPLY AIR DUCT RISER <br />® ® <br />PPLYAIRGRILLE <br />EUMATIC -CV® <br />EX CONNECTOR <br />(N)m m(E) <br />NEW RECTANGULAR OUTSIDE AIR DUCT RISER <br />RNAI <br />RETURGRILLE <br />'�Q^II ,�,I <br />-LIT_ <br />PNEUMATIC SW -CV <br />m <br />TWIN RUBBER SPHERICAL CONNECTOR <br />(N)� �(E) <br />NEW(N)aEXISTING B) RECTANGULAR RETURN AIR DUCT RISER <br />® ®EXHAUST <br />GRIUF <br />EUMATC eUTT--zw-cv <br />O00TRIPLE <br />GROOVED COUPLINGS <br />(N)® �(E) <br />HE IN) &EXISTING(EI RECTANGULAR EXHAUST AIR DUCT RISER <br />O <br />ROUND DIFFUSER <br />�M Iy <br />PNEUMATIC BUTTERFLY 3W-CV(DIVERTING) <br />[ <br />ENDCAP <br />(N) (E) <br />NEW (N)& EXISTING E) ROUND AIR DUCT RISER <br />o <br />LNEAR DIFFUSER <br />tM <br />PNEUMATIC BUTTERFLY iW-CV(MIXING) <br />BLIND FLANGE <br />NEW SINGLE LINE. DOUBLE LINE RECTANGULAR OR ROUND DUCT <br />SIDEW FILLE <br />MOTORIZED 2W-CV <br />D <br />CONCENTRIC REDUCER <br />EXIST.. SINGLE UNEa DOUBLE LINE RECTANGULAR OR ROUND DUCT <br />WALLLOUVER <br />TO-ED Bwcv <br />L <br />ECCENTRIC REDUCER <br />x-xSINGLE <br />LINEDUCTWDRXDEMOLISHED .OPTION' <br />Isnrvc DOUBLE LINE DUCTWORK BE DEMOLISHED CX?GPTIDN) <br />o 0 <br />IRAL SIDEW ALL WITH EXTRACTORawITHour EXTRwcTOR) <br />To.rz.D BUTTERFLY zwcv <br />ICI <br />UNION <br />�X—X—X <br />x — x-1 <br />Lx <br />EXISTING DUCTWORK TO BE DEMOLISHED IHATCH OPTION) <br />11�1�111j IL�e\\ <br />FLEXIBLE DUCT <br />'M ' <br />MOTORIZED BUTTERFLY 3W-CV(DIVERTING) <br />n <br />SCHRADERVALVE <br />V�J <br />DUCT WITH WRAP DIMENSIONS SHOWN AGEIO OF DUCT <br />EFAULTWRAPTHICKNESS=I.S� UNLEESOTHERWISENOTEO ON PLANS <br />SYMBIOL SHE ET NUMBER NCALL OUF <br />tM It <br />_} <br />MOTORIZED BUTTERFLY SWCV (MIXING) <br />FLOW ARROW <br />24'x12'(2'L)DUCT <br />��-- <br />WITH LINING. DIMENSIONS SHOWN ARE I.D. OF DUCT <br />2 2X12 3 <br />450 <br />: <br />^xGRILLEIDIFFUSER TAGDE <br />CFLLHDIFFUSERTYPE STZ <br />GATE VALVE <br />ESSURE GAUGE WITH SHUT-OFF VALVE <br />-1 LINING TH—ES. = <br />mP.2) a <br />V <br />IN.UE a DOUBLE LINE DUCTWORK WITH TRANBmONAL FITTING <br />EO <br />UIPMENT LABEL TAG <br />(�BALL <br />VALVE <br />Up <br />TEMPERATURE SENSOR a THERMOWELL <br />SQUARE <br />® FOUNDDOUBLE <br />LINE SQUARE TO ROUND TRANSRIGNAL FITTING <br />® <br />ILING OR DUCT ACCESS PANEL BY GENERAL CONTRACTOR <br />BALL VALVE WITH MEMORY STOP <br />THERMOMETER <br />(D0 OI'*.,11 <br />(D-RADIUSELBOW@ IN' SQUARE ELBOW WITH TURNING VANES <br />�► � <br />FLOW ARROW&FLOW ARROW -CURVED <br />GLOBEVALVE <br />T <br />PETE'S PLUG <br />OI ® O® <br />()ROUND DUCT TURNING VERTICAL (2 RECT. DUCT TURNING VERTICAL <br />�) <br />VISIOMCLOUD <br />1� <br />II I <br />"''R 7777"�f <br />TTERFLY VALVE <br />FSg <br />OW SWITCH <br />GUE LINE MANUAL VOLUME DAMPER <br />uBLE LINE MANUAL VOLUME DAMPER <br />NTRACTOR LINE TRAP TO APPROVED RECEPTOR PLUMBwc, <br />ECKVALVE <br />fakk \}TRIPLE <br />DUTYVALVE <br />MOTORIZED DAMPER(ELECTRIC) <br />FLOOR SINK WITH TRAP TO APPROVED RECEPTOR BY PLUMBING <br />CONTRACTOR <br />STRAINER <br />LLL1 <br />FEUEFVALVE <br />IPH'g IpIE3 <br />TO-ED DAMPER(PNEUMATIC) <br />GAS STUBUP BY PLUMBING CONTRACTOR <br />STRAINER WITH.LOWDOWN VALVE <br />1��� <br />WAY WP%VPLVE <br />k 1 <br />FIRE DAMPER (SINGLE LINE AND DOUBLE LINE) <br />COLD WATER STUB ­UP BY PLUMBING CONTRACTOR <br />�r <br />SKETSTRAINER <br />5-� <br />VACUUM BREAKER <br />E <br />❑'j <br />PRE/SM.— DAMPER (sIrvGLE LINE AND DOUBLE LINE) <br />) <br />EUECTRICALEON <br />CATION BYEEICTRICAL CONTRACTORI <br />�--�iiii7 <br />.TON DIFILEER <br />�TSTEAM <br />TRAP <br />� <br />DSD I1}F=�=,II <br />SMOKE DETECTOR(DUCTTYPE) <br />Q <br />VISION DELTA <br />AIRVENT MANUAL <br />III���� <br />ANGLE VALVE <br />STATIC PRESSURE SENSOR <br />POINT OF CONNECTION <br />AIR VENT -AUTO <br />® <br />SIGHT GLASS <br />SD <br />o DETECTOR (AREA TYPE) <br />® <br />GUTATOR <br />PRESSURE REDUCING VALVE <br />FILTER DRIER <br />0. <br />ERMO.— WITH -NE NUMBER <br />PRESSUREsusTAININcVALVE <br />4-SOLENOIDVALVE <br />CO <br />2sENSOR <br />® <br />TOPLOWCONTROL <br />WITH SENSING BULB <br />NO2 SENSOR <br />CIRCUITSETTER <br />RESSUREGAUGE-STEAM <br />coDO <br />SENSOR <br />PAUL VALVEWITHHQ3EDQNNECTIQNDIFFERENTIALPRESSURE <br />SE.S.R <br />OC <br />CUPANCYBENBOR <br />FLOW METER wuNE <br />HOSEBIBS <br />® <br />LSWITCH <br />FM <br />FLOWMETER TURBIHE <br />ABBREVIATIONS <br />AFF <br />ABOVE FINISHED FLOOR <br />(D) <br />DEMO <br />HT <br />HEIGHT <br />OD <br />OUTSIDE DIMENSION <br />TSTAT <br />THERMOSTAT <br />AHJ <br />AUTHORITY HAVING JURISDICTION <br />CIA <br />DIAMETER <br />HHWR <br />HEATING HOT WATER RETURN <br />OPN'G <br />OPENING <br />TU <br />TOP UP <br />AP <br />ACCESS PANEL <br />DSD <br />DUCT SMOKE DETECTOR <br />HHWS <br />HEATING HOT WATER SUPPLY <br />OSA <br />OUTSIDE AIR <br />TYP <br />TYPICAL <br />ASD <br />AREA SMOKE DETECTOR <br />DWG <br />DRAWING <br />HPG <br />HIGH PRESSURE GAS <br />PLBG <br />PLUMBING <br />UBC <br />UNIFORM BUILDING CODE <br />BDD <br />SACKDRAFT DAMPER <br />(E) <br />EXISTING <br />HPS <br />HIGH PRESSURE STEAM <br />POC <br />POINT OF CONNECTION <br />UC <br />UNDERCUT <br />BF <br />BOTTOM FLAT <br />EA <br />EXHAUST AIR <br />HVLS <br />HIGH VELOCITY LOW SPEED FAN <br />RECIP <br />RECIPROCATING <br />UG <br />UNDERGROUND <br />BOD <br />BOTTOM OF DUCT <br />EG <br />EXHAUST AIR GRILLE <br />ID <br />INSIDE DIMENSION <br />(R) <br />RELOCATE <br />ILIAC <br />UNIFORM MECHANICAL CODE <br />Sol <br />BOTTOM OF INSULATION <br />ELB <br />ELBOW <br />INS <br />INSULATION <br />RA <br />RETURN AIR <br />UNO <br />UNLESS NOTED OTHERWISE <br />BOP <br />BOTTOM OF PIPE <br />ELEC <br />ELECTRICAL <br />INT <br />INTERIOR <br />RED D <br />REQUIRED <br />UTR <br />UP THROUGH ROOF <br />CA <br />COMPRESSED AIR <br />EQ <br />EQUIPMENT <br />(L) <br />LINED <br />REV <br />REVISION <br />V <br />VENT <br />CD <br />CONDENSATE <br />EXH <br />EXHAUST <br />LR <br />LINEAR RETURN <br />RG <br />RETURN OR TRANSFER GRILLE <br />VAV <br />VARIABLE AIR VOLUME <br />CE <br />CEILING EXHAUST <br />EXT <br />EXTERIOR <br />LS <br />LINEAR SUPPLY <br />RG <br />REFRIGERANT GAS <br />VFD <br />VARIABLE SPEED DRIVE <br />CENTR <br />CENTRIFUGAL <br />(F) <br />FUTURE <br />MA <br />MIXED AIR <br />RGHP <br />REFRIGER/WTGAS-HIG�-I PRESSURE <br />VIF <br />VERIFY IN FIELD <br />CFF <br />CAP FOR FUTURE <br />FD <br />FIRE DAMPER <br />MECH <br />MECHANICAL <br />RH <br />REHEAT <br />VOL <br />VOLUME <br />CFM <br />CUBIC FEET PER MINUTE <br />FLEX <br />FLEXIBLE <br />MPG <br />MEDIUM PRESSURE GAS <br />RL <br />REFRIGERANT LIQUID <br />WMS <br />WIRE MESH SCREEN <br />CHWR <br />CHILLED WATER RETURN <br />FLR <br />FLOOR <br />MFR <br />MANUFACTURER <br />RMF <br />RAPID MOUNT FRAME <br />XFER <br />TRANSFER <br />CHWS <br />CHILLED WATER SUPPLY <br />FLU <br />FLUE <br />MD <br />MOTORIZED DAMPER <br />RNA <br />ROUND NECK ADAPTER <br />CL <br />CENTERLINE <br />FIR <br />FLOOR RETURN <br />MTD <br />MOUNTED <br />FIND <br />ROUND <br />CLG <br />CEILING <br />FS <br />FLOOR SUPPLY <br />MTL <br />METAL <br />RR <br />REFRIGERANT RELIEF <br />CMU <br />CONCRETE MASONRY UNIT <br />FSD <br />FIRE SMOKE DAMPER <br />MUA <br />MAKE UP AIR <br />RS <br />REFRIGERANT SUCTION <br />CO <br />COOLING ONLY <br />GA <br />GAUGE <br />MVD <br />MANUAL VOLUME DAMPER <br />SA <br />SUPPLY AIR <br />CA <br />COMBUSTION AIR <br />GALV <br />GALVANIZED <br />NG <br />NATURAL GAS <br />SG <br />SUPPLY GRILLE <br />CONIC <br />CONCRETE <br />GC <br />GENERAL CONTRACTOR <br />(N) <br />NEW <br />SM <br />SHEET METAL <br />COND <br />CONDENSATE <br />GEXH <br />GREASE EXHAUST <br />N/A <br />NOT APPLICABLE <br />SS <br />STAINLESS STEEL <br />CONN <br />CONNECTION <br />GPH <br />GALLONS PER HOUR <br />NC <br />NORMALLY CLOSED <br />STD <br />STANDARD <br />CONT'R <br />CONTRACTOR <br />GPM <br />GALLONS PER MINUTE <br />NIC <br />NOT IN CONTRACT <br />TA <br />TRANSFER AIR <br />CR <br />CEILING RETURN <br />GR <br />GLYCOL RETURN <br />NO <br />NORMALLY OPEN <br />TD <br />TOP DOWN <br />CS <br />CEILING SUPPLY <br />GS <br />GLYCOL SUPPLY <br />NTS <br />NOT TO SCALE <br />TF <br />TOP FLAT <br />CWR <br />CONDENSER WATER RETURN <br />GYP <br />GYPSUM BOARD <br />DIED <br />OPPOSED BLADE DAMPER <br />TOD <br />TOP OF DUCT <br />CWS <br />CONDENSER WATER SUPPLY <br />HOA <br />I HAND -OFF -AUTO <br />OC <br />I ON CENTER <br />TOP <br />I TOP OF PIPE <br />DRAWING INDEX <br />DRAWING INDEX KEY: <br />NOT INCLUDED WITH ISSUE <br />NEW OR REVISED <br />O NO CHANGES <br />LL <br />U <br />LL I <br />LU <br />L <br />� <br />~ <br />w <br />o <br />SNOT <br />DRAWING TITLE <br />MO.00 <br />COVER SHEET <br />MI <br />CONSTRUCTION REQUIREMENTS <br />M0.03 <br />PERMIT REQUIREMENTS <br />M1.01 <br />1 ST FLOOR HVAC PLAN <br />M5.01 <br />MECHANICAL DETAILS <br />_H <br />H—L—M <br />SCOPE OF WORK I <br />1. REMOVE & REPLACE (2) PACKAGE HEAT PUMPS. <br />APPLICABLE CODES <br />WASHINGTON MECHANICAL PROJECTS: <br />ALL WORK SHALL BE IN FULL ACCORDANCE WITH APPLICABLE <br />LOCAL, STATE, AND FEDERAL CODES, LAWS AND REGULATIONS. <br />ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH, <br />BUT NOT LIMITED TO: <br />• 2018 INTERNATIONAL BUILDING CODE WITH WA AMENDMENTS <br />• 2020 NATIONAL ELECTRICAL CODE WITH WA AMENDMENTS <br />• 2018 INTERNATIONAL MECHANICAL CODE WITH WA AMENDMENTS <br />• 2018 UNIFORM PLUMBING CODE WITH WA AMENDMENTS <br />• 2018 WASHINGTON STATE ENERGY CODE <br />• 2018 INTERNATIONAL FIRE CODE WITH WA AMENDMENTS <br />ALL WORK SHALL BE IN ACCORDANCE WITH THE FOLLOWING <br />ADDITIONAL GUIDELINES WHERE REQUIRED BY CODE: <br />• SHEET METAL AND AIR CONDITIONING CONTRACTORS <br />NATIONAL ASSOCIATION (SMACNA) <br />• AMERICAN SOCIETY OF HEATING, REFRIGERATION AND <br />AIR-CONDITIONING ENGINEERS (ASHRAE) <br />• AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) <br />• AMER SOCIETY OF CIVIL ENGINEERS (ASCE) <br />• NATIONAL FIRE PROTECTION AGENCY (NFPA) <br />• OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) <br />PROPERTY INFORMATION <br />PARCEL #: 28051800404300 <br />LEGAL DESCRIPTION: SEC 18 TWP 28 RGE 05LOT 3A EVERETT <br />MALL PLAZA - PHASE III BSP REC'D V1 MISC MAPS PG 22- 23 AF <br />NO 8412195037 BEING PTN OF NW114 SE1/4 TGW W 40FT OF TH <br />PTN EVERETT MALL WAY LY ADJ THRTO VAC PER CITYOF EV <br />ORD NO 1290-86 REC AF 8612240099 <br />enSim <br />newed <br />sy <br />5300 DENVER AVENUE SOUTH <br />SEATTLE, WASHINGTON 98108 <br />(206)787-8500 <br />THE PLANS AND SPECIFICATIONS HEREIN <br />ARE OWNED BYAND FOR THE SOLE USE OF <br />ACCO ENGINEERED SYSTEMS, INC. (-ACCO-), <br />AND MAYNOT BE REPRODUCED OR USED <br />BY OTHERS FOR ANY PURPOSE UNLESS <br />AUTHORIZED BYACCO IN WRITING. ACCO <br />CANNOTACCEPTANYLIABILITY, WARRANTY, OR <br />OBLIGATION IN THE EVENT OF UNAUTHORIZED USE. <br />AREA OF WORK <br />KEY PLAN <br />9R �sCq� <br />o47107 <br />AONAi. K^ <br />EXPIRES: 11-28-2024 <br />1 <br />09/01/2023 <br />PERMIT SET <br />TD <br />No. <br />Date <br />Description <br />By <br />Revisions <br />Project <br />EVERETT MALL <br />UNIT REPLACEMENT <br />1201 SE EVERETT MALL WAY, ST. D <br />EVERETT, WA. 98208 <br />Title <br />COVER SHEET <br />T.DALGLEISH T.TOLITONGHI <br />Designed By Checked By <br />T.DALGLEISH D.RISTOW <br />Drawn By Project Manager <br />70870663 AS SHOWN <br />Job Number Scale <br />M0.00 <br />